Instrukcja obsługi Statron 5359.3


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Statron 5359.3 (3 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/3
power supply type 5359.3
read the instruction book careful before first use of the power supply. With harms, the through non-observance
this instruction accrue, extinguishing the claim under guarantee plus cubit liability of the manufacturer from the
follow the non-observance.
1. Bestimmungsgemäßer Gebrauch
this appliance is for the operational in closed rooms . It's at a safe fixedplace plus a sufficient ventilation to
observe (ventilating louvres non- uncover!).
The appliance serves the provision a AC voltage or a d.c. voltage switchable of 2 V to 14 V/max.5A.
2. Safety notes
2,1 the power supply unit is in safety class system I as well as in accordance with VDE 0411 and VDE 0805
(EN60950) structured. The supply transformer is structured and with 3,75 kVeff is primarysecondarily
checked according to DIN VDE 0551 as safety insulating transformer. It is radio-screened in accordance with
VDE 0875T11 curve B. Es is equipped with a VDE checked main with protective grounding and may
therefore only to 230-V-AC input voltage with protective grounding be operated or attached.
2,2 it is to be made certain that protective grounding (yellow/green) is interrupted neither in the main nor in the
device or in the network, since with interrupted protective grounding mortal danger exists. It is to be made
certain further that the isolation is damaged nor destroyed neither.
2,3 power supply units do not belong into child hands!
2,4 in commercial mechanisms is to be considered the rules for the prevention of accidents of the federation of
the commercial professional association for electrical system and resources.
2,5 in schools, training facilities, hobby and self-help workshops. is by hand possible for
2,6 when opening covers or removing from sections, except if this, can live sections be opened. Also interface
can be live. Before an alignment, maintenance, a repair or an exchange of sections the device must be
separate from all voltage supplies, if opening of the device is necessary. If thereafter an alignment,
maintenance or a repair at the opened device under voltage are inevitable, may take place only by means of
a specialist, who is familiar with the associated dangers or the relevant regulations for it.
2,7 condensers in the device can be still loaded, even if the device were separated from all voltage supplies.
2,8 it is to be guaranteed that only protections of the indicated type and the indicated call stromstraerke are used
as back-up. The use of repaired protections or bridging the fuse holder is illegal. The device is overload-proof
and short-circuit-protected. When burning the input protection through a serious error is therefore present,
which must be eliminated by a specialist, before the new intact protection can be used by this specialist.
2,9 switching it your power supply unit never equivalent if it is brought by a cold into a warm space. The
condensation developing thereby can destroy your device under unfavorable circumstances. Let the device
unein switched to room temperature come. carrying of metallic or conductive decoration is forbidden to
2,10 with work with power supply units such as chains, bracelets, rings or the like.
2,11 power supply units are not certied for application at humans or animals.
2,12 during the series connection of the outputs one or several power supply units is produced lethal voltages (>35
VDC).
2,13 louvers of power supply units may not be taken o! The devices are on hard to place with diculty
inflammable documents so that air can occur the devices unhindered. The cooling of the devices takes place
predominantly via convection.
2,14 power supply units and the attached consumers may not be operated unsupervised. Measures are to be
taken to the protection and the protection of the attached consumers in relation to effects of the power supply
units (e.g. overvoltages, failure of the power supply unit) and the effects and dangers outgoing from the
consumers themselves (e.g. illegally high power input). Note! Sensitive consumers must be protected
additionally by external measures against destruction!
2,15 in the event of an error can deliver power supply units voltages over 50 V DC voltage, from which dangers
proceed, also then if the indicated output voltages of the devices lower is situated.
2,16 with work under voltage for it expressly certified tools may be only used.
2,17 the outputs of the power supply units (exit hub/clamps) and to it attached lines must be protected against
direct contact. In addition the used lines must sufficient isolation or tension strain possess and the contact
points be contact-voltage-proof (safety sockets).
2,18 shifting metallically bright lines and contacts is to be avoided. All these places are by suitable to take and to
protect thus against direct contact with difficulty inflammable insulants or other measures off. Also the
electrically leading sections of the attached consumers are to be protected by appropriate measures against
direct contact.
2,19 if to assume it is that a safe operation is no longer possible, then is the device out of operation to set and
against unintentional operation protect. It is to be assumed that a safe operation is no longer possible, if - the
device or the mains cable visible damages indicates, - the device any longer does not operate, - after longer
storage under unfavorable conditions, - after heavy transport stresses.
3. operating
the appliance becomes a associate to the mains plug St 1 at a earthing contactsocket 230 V / 50 Hertz
connected.Is responsible for seeing that the mains cable thus mislays will, that a damage the mains cable plus
uni- pull down of the apparatus prevents will. With that of the mains switch S1 becomes a the appliance
switched on and is thusaway ready for operation. With that of the turn-switch can the output voltage ac plus dc
via the built in bridge recitifier associate subsequent electrolyt capacitor in 2 V stepped discontinued will. The
decay the voltage takes place of the marked connector. The output voltage are additional a thermal automatic
circuit breaker provided security for.
4. Application
the input voltage 230V / 50 Hertz is via the internal fuse Si1 plus the mains switch to transformer put. All output
voltage are galvanic from the net separate. With that of the change-over switch can the on the silk-screen
printing stated voltages discontinued will. The built in bridge recitifier associate following charging condenser
smooths the d.c. voltage. It I am allowed respective only one the exits charged will. With overcharge detaches
the thermal cutout from, this can additional removal of the cause again set will. The appliance is universal
usable, particularly in indoctrinate plus schools. For reasons of safety is additionally assistant the ventilation slot
uni- colander welded..
5. security advice
Alternating the built in fuse si 1 :
attention ! It I am allowed only the prescribed fuse (value see sticker)
of a specialist changed will !
The cutout can additional removal of the overload from the user auto- again set will.,
Type 85 21 112
spezification isolating transformer
*output voltage AC 2-14V
bridge rectifier
* output voltage DC 2-14V
*output current 5A
dimensions (B x H x T): 140 x 130 x 210 mm
wigth 3,0 kg
Input voltage 230V +/-10% 50 Hz
output voltage DC elko DC output
display screenprint
Safty class I
mains fuse: Fuse in the side and circuit breaker
color RAL 7035
Connection input AC power line
Connection output 4 mm clamp
Insulation test voltage EN61010; EN61558-2-4
Operating temperature 0 - 50°C
EMV EN61000-6-3; EN61000-6-2


Specyfikacje produktu

Marka: Statron
Kategoria: nieskategoryzowany
Model: 5359.3

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Statron 5359.3, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Statron

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024