Instrukcja obsługi SchwankAir MonsterFans MF-ST08-SL

SchwankAir Ventilator MonsterFans MF-ST08-SL

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla SchwankAir MonsterFans MF-ST08-SL (12 stron) w kategorii Ventilator. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/12
schwankgroup.com/monsterfans
MonsterFans Style Series
Installation Manual
2schwankgroup.com/monsterfans
Table Of Contents
Overview ..............................................................................................................................................3
Components .................................................................................................................................3
Technical Data ....................................................................................................................................4
Fusing and Thermal Limiting ...............................................................................................................5
Fuses...............................................................................................................................................5
Thermal Limiting ............................................................................................................................5
Safety ....................................................................................................................................................6
Clearances ...................................................................................................................................
Installation Preparation.......................................................................................................................7
Preparation ...................................................................................................................................7
Tools Required ..............................................................................................................................7
Items Included ..............................................................................................................................7
Hardware Included ......................................................................................................................7
Installation Procedure .........................................................................................................................9
Installation of the Mounting Hardware .....................................................................................12
Installing the Blades ....................................................................................................................14
Installing the LED Light Kit................. ...........................................................................................15
Installing the Hub Cover [with Lens] ..........................................................................................16
Electrical Installation ..........................................................................................................................18
HMI Control .........................................................................................................................................19
HMI/CAT 5 Cable Connection ..................................................................................................19
Maintenance ......................................................................................................................................20
Recommended Maintenance Schedule ................................................................................21
4schwankgroup.com/monsterfans
Technical Data
Conformity CE Low Voltage [2006/95/EC] & EMC [2004/108/EC]
Directives
EN61000-6-2:2005, EN61000-6-4:2007
IEC 60335-2-80:2015 IEC 60335-1:2015
Approvals UL61800-5-1
CSA C22.2 No113
Input Voltage Phase
Imbalance
≤2%
Input Voltage 110-240 VAC
Input Current 4.6 @ 120VAC, 2.5A @ 240VAC
Input Frequency 50-60Hz
Supported Power Systems TT TN For central ground systems, operation is permitted
without restrictions.
Humidity ≤ 95% Non-condensing
Temperature Range Transport -40°F…+160°F [40°C...+70°C]
Storage -40°F…+160°F [40°C...+70°C]
Operation -40°F…+120°F [40°C...+50°C] [with speed derating
above +104°F]
Installation Altitude 0-13,000 ft [0-4000 m]
above sea level
[with 5%/3000ft current derating above 3000ft]
Earth Leakage Current <=9 mA to PE
Power Conductor Size [Cord] Minimum 16AWG 3 Conductors rated 300VAC, use Copper Conductors
only.
For permanent connection only.
Max. Permissible Control Ca-
ble Length
100 ft un-shielded
Enclosure IP54/ NEMA 3
Protection Measures Against Short circuit, earth fault, phase loss, over voltage, under voltage, motor
stalling, over temperature, motor overload, communication loss
Environment For indoor use/outdoor
Thermal Overload Protection Drive provides internal overload protection for the motor
Pollution Degree 2
Overvoltage Category Category lll
Supply Earthing System TN-S
Impulse Voltage 2500V
Working System Voltage 150V
Packaged Fan Weight 98 lbs [44.5 kgs]
Overall Fan Weight
[no mount]
85 lbs [38.5 kgs]
LED Light Kit Weight 1.542 lbs [0.669 kgs]

Specyfikacje produktu

Marka: SchwankAir
Kategoria: Ventilator
Model: MonsterFans MF-ST08-SL

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z SchwankAir MonsterFans MF-ST08-SL, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Ventilator SchwankAir

Instrukcje Ventilator

Najnowsze instrukcje dla Ventilator

DCG

DCG VECRD60TL Instrukcja

20 Września 2024
Argoclima

Argoclima Fanny Instrukcja

20 Września 2024
Canarm

Canarm Calibre XV Instrukcja

20 Września 2024
Izzy

Izzy IZ-9031 Instrukcja

20 Września 2024
Canarm

Canarm AX36-7 Instrukcja

20 Września 2024
Lasko

Lasko B20301 Instrukcja

20 Września 2024
Teesa

Teesa TSA8032 Instrukcja

19 Września 2024