Instrukcja obsługi Satel S-3
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Satel S-3 (2 stron) w kategorii Czujnik Deur/ramki. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/2
S-1 / S-2 / S-3
MAGNETIC CONTACT
s123_en 08/19
The S-1 / S-2 / S-3 magnetic contact can detect opening of a door, window, etc. Additionally, it is
provided with a tamper loop. The S-1 magnetic contact is designed for surface mounting, and the S-2
and S-3 magnetic contacts – for flush mounting.
1. Description
The device consists of a contact (reed switch) and a magnet. Moving the magnet away from the
contact (opening the door or window) opens the reed switch contacts (thus triggering alarm).
Both magnetic contact elements are placed in identical waterproof enclosures. The S-1 and S-2
enclosures are made of plastic, while the S-3 enclosure is made of metal. The contact has 4 wires.
The two twisted wires are a tamper loop. The contacts are shown in the figures below.
2. Installation
The contact should be mounted on a fixed surface (e.g. window or door frame), and the magnet on
a movable surface (e.g. window or door). Do not install the magnetic contact on ferromagnetic
surfaces and near to strong magnetic and electrical fields, because it can result in malfunctioning of
the device. When mounting the magnetic contact, you must take into account the make distance.
The S-1 magnetic contact is designed for surface mounting. Place the contact and magnet in parallel
next to each other (Fig. 4). The magnetic contact elements can be attached with screws, double-sided
tape or glue.
The S-2 and S-3 magnetic contacts are designed for flush mounting in wood or plastic. Place the
contact and magnet facing each other (Fig. 5 – as shown by the example of S-3). To make holes for
2 S-1 S-2 S-3 SATEL
the magnetic contact elements, use a ø9 mm drill. Press the S-2 magnetic contact elements or screw
the S-3 magnetic contact elements into the holes made.
Notes:
Do not use a hammer to drive the contact into the hole (it may damage the reed switch).
When screwing the S-3 contact into the hole, the wires become twisted. To prevent them from
damage, twist the wires against the direction of screwing before installation.
magnet.
contact.
A – make distance.
B – permissible offset between contact and magnet axes: S-2 = 10 mm, S-3 = 12 mm.
C – minimum thickness of the wall in which magnetic contact elements can be mounted: 10 mm.
3. Specifications
Magnetic contact type......................................................................................................................... NC
Maximum switching voltage.............................................................................................................. 20 V
Maximum switching current ........................................................................................................... 20 mA
Contact resistance.......................................................................................................................150 mΩ
Minimum life expectancy (20 V, 20 mA) ......................................................................................360 000
Contact material ...............................................................................................................Ru (ruthenium)
Make distance S-1................................................................18 mm
S-2................................................................28 mm
S-3................................................................15 mm
Break distance S-1................................................................28 mm
S-2................................................................40 mm
S-3................................................................24 mm
Environmental class according to EN50130-5........................................................................................II
Operating temperature range ............................................................................................ -10°C...+55°C
Maximum humidity........................................................................................................................ 93±3%
Weight S-1....................................................................29 g
S-2....................................................................28 g
S-3....................................................................43 g
The declaration of conformity may be consulted at www.satel.eu/ce
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu
Specyfikacje produktu
Marka: | Satel |
Kategoria: | Czujnik Deur/ramki |
Model: | S-3 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Satel S-3, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Czujnik Deur/ramki Satel
23 Września 2024
20 Września 2024
18 Września 2024
Instrukcje Czujnik Deur/ramki
- Czujnik Deur/ramki Bosch
- Czujnik Deur/ramki Hikvision
- Czujnik Deur/ramki EZVIZ
- Czujnik Deur/ramki Nedis
- Czujnik Deur/ramki Nexa
- Czujnik Deur/ramki ORNO
- Czujnik Deur/ramki Emos
- Czujnik Deur/ramki Homematic IP
- Czujnik Deur/ramki Kidde
- Czujnik Deur/ramki Kanlux
- Czujnik Deur/ramki Axis
- Czujnik Deur/ramki Abus
- Czujnik Deur/ramki Olympia
- Czujnik Deur/ramki Optex
- Czujnik Deur/ramki Schwaiger
- Czujnik Deur/ramki Fibaro
- Czujnik Deur/ramki Vivanco
- Czujnik Deur/ramki Smartwares
- Czujnik Deur/ramki Caliber
- Czujnik Deur/ramki Energenie
- Czujnik Deur/ramki Techly
- Czujnik Deur/ramki Steren
- Czujnik Deur/ramki Konig
- Czujnik Deur/ramki Xavax
- Czujnik Deur/ramki X4-Tech
- Czujnik Deur/ramki Tellur
- Czujnik Deur/ramki Gewiss
Najnowsze instrukcje dla Czujnik Deur/ramki
14 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024