1
A C O R B AT T E R Y P O WERE D
S I N K W I T H E L E C T R O N I C S E N S O R
Operating Manual for Hands-Free Wall Mount Stainless Steel Sink
AC Models 608A and 608A-0.5
Battery Models 608B and 608B-0.5
of Domestic and Foreign Parts
Columbia does not recommend use with harsh chemicals.
Product Compliance
NSF/ANSI 2 Food Equipment, NSF/ANSI 372 Lead-Free Compliant, ASME A112.18.1
2
COLUMBIA SPECIFICATIONS
A C O R B AT T E R Y P O W E R E D
S I N K W I T H E L E C T R O N I C S E N S O R
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
Installation Instructions
Step 1
1. Establish sink location on the wall.
2. Determine desired height for the top of the backsplash from finished floor and draw a level
line which will be the top edge of the wall mounting bracket.
3. Hold the wall mounting bracket against the wall and mark the wall where the holes are. Drill
holes and secure bracket to the wall as shown in illustration A. Screws are not provided.
Step 2
1. Install strainer assembly.
2. Install faucets to the sink following the instructions provided with sensor unit.
3. Attach supply tube with elbow to back of faucet.
4. Install mixing check valve and compression fitting to control box of each sensor faucet.
Step 3
1. Position the sink onto wall bracket.
2. Loosely attach support brackets under sink and push against wall then mark holes for
drilling as shown in illustration B.
3. Remove support brackets from sink and drill holes for mounting fasteners (not provided).
4. Re-mount support brackets to sink and fasten to wall.
Step 4
1. Connect waste line to strainer assembly (s).
2. Mount sensor control box at desired location on wall.
3. Connect power line from sensor to control box.
4. Attach supply tube from faucet to control box.
5. Connect hot and cold water from the source to mixing check valve (s).
6. Remove aerator from the spout assemblies and flush water system. (see step 7 sensor
installation instructions)
7. Check connections for leaks.
8. Replace aerator onto the spout (s).
9. We recommend sealing top of backsplash to wall as shown in illustration C.
Parts List
(1) Wall mount sink
(1) AC or Battery powered sensor faucet assembly
(1) Wall-mounting bracket
(2) Support brackets
(4) Support bracket mounting bolts and washers
(1) Mixing check valve
(1) Strainer assembly with basket
Tools Required
Tape measure
Adjustable wrench
Drill motor and drill bits
Pipe wrench
Level
Safety glasses
Screw drivers: phillips and standard
Pencil
Socket wrench
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE: Lead content originates from Brass components in valves and faucets and is certied under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers
Go to for more information on replacement parts and installation videos.columbiasinks.com
Illustration A
Illustration B
Illustration C
3
COLUMBIA SPECIFICATIONS
A C O R B AT T E R Y P O W E R E D
S I N K W I T H E L E C T R O N I C S E N S O R
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
Wall-mounting bracket
9” (228.6mm)
19” (482.6mm)
9.5”
(241.3mm) 9.5”
(241.3mm)
16”
(406.4mm)
12.5”
(304.8mm)
1.5” (38mm)
2” (51mm)
Front
Top
18” (457.2mm)
16” (406.4mm)
.875” (22mm)
dia. hole (1)
Hole Configuration
9.5”
(241.3mm) 9.5”
(241.3mm)
6” (152.4mm)
1.5” (38mm)
6” (152.4mm)
4” (101.6mm)
2” (50.8mm)
8.25”
(209.5mm)
1.5”
(38.1mm) .875”
(22.22mm)
Back
Splash
.25”
dia. hole
9” (228.6mm)
45º
7” (177.8mm)
Side 16” (406.4mm)
2” (51mm)
1.5” (38mm)
14” (355.6mm)
2” drain hole
7.5” (191mm)
.5” R
(12.7mm)
.5” R (12.7mm)
Wall Mounting Detail
Specyfikacje produktu
Marka: | Sani-Lav |
Kategoria: | Zlew |
Model: | 608A |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Sani-Lav 608A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Zlew Sani-Lav
23 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
Instrukcje Zlew
- Zlew Teka
- Zlew Smeg
- Zlew Concept
- Zlew Nodor
- Zlew Hotpoint Ariston
- Zlew CDA
- Zlew Artusi
- Zlew Oliveri
- Zlew Franke
- Zlew Caple
- Zlew Kernau
- Zlew Foster
- Zlew Deante
- Zlew BLANCO
- Zlew Rangemaster
- Zlew Leisure
- Zlew Elkay
- Zlew Schock
- Zlew Roca
- Zlew Advance Tabco
- Zlew Laveo
- Zlew Tot Mate
- Zlew Kuchinox
- Zlew Shaws
Najnowsze instrukcje dla Zlew
14 Października 2024
13 Października 2024
13 Października 2024
13 Października 2024
13 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024