F L O O R M O U N T S I N K 1
Operating Manual for Floor Mount Stainless Steel Sink
Models 524F and 524F-0.5
of Domestic and Foreign Parts
Columbia does not recommend use with harsh chemicals.
Product Compliance
NSF/ANSI 2 Food Equipment, NSF/ANSI 61, Section 9, ASME A112.18.1/CSA B125.1
2
F L O O R M O U N T S I N K
COLUMBIA SPECIFICATIONS
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
Installation Instructions
Step 1
1. 1. Attach upper and lower leg support brackets to legs with hardware (provided).
2. Place wash station sink on the leg assembly. Secure legs to bowl with hardware provided.
3. Place wash station sink at the desired location.
4. Mark the floor where the mounting holes are at the base of the legs. See illustration A.
5. Drill holes as required for mounting hardware. Hardware not included.
Step 2
1. Install Faucet to the sink using faucet mounting kit provided. We recommend using pipe thread
sealant instead of Teflon tape.
2. Install strainer assembly to the drain hole.
3. Connect hot and cold water supply lines (not included) to the back of faucets.
Step 3
1. Position wash station sinks to pre-drilled holes and secure sink to the floor.
2. Connect waste line or drain pipe to the strainer assembly. Not included.
3. Connect water supply lines (Hot and Cold) to the water source. Not included.
4. Remove aerator from the spout and flush the water system.
5. Replace aerator to the spout.
6. Check for leaks and tighten connections if necessary.
Step 4
1. Seal gap between bowl and leg assembly as shown in illustration B.
2. When mounting against wall, it is recommended sealing the top of the backsplash to wall as
shown on illustration C.
Parts List
(1) Floor mount sink
(1) Leg assembly set
(6) Nuts, bolts and washers for leg assembly
(4) Washers and nuts for connection sink to leg assembly set
(1) 8” on center faucet
(1) Faucet mounting kit
(1) Strainer assembly with basket
Trouble Shooting Guide
Problem Possible Cause To Diagnose Remedy
Water drips from
the spout or from
under the lever.
1. Seat washer is worn
2. Seat is worn
3. O-rings are worn
Shut cold water source off. See if
water still leaks from the spout. If
leaks continues repair hot side if
not repair cold side.
Recommend
installing hot
or cold faucet
repair kit.
Go to for more information on replacement parts and installation videos.columbiasinks.com
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE: Lead content originates from Brass components in valves and faucets and is certied under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers
Tools Required
Tape measure
Adjustable wrench
Drill motor and drill bits
Pipe wrench
Level
Safety glasses
Screw drivers: phillips and standard
Pencil
Socket wrench
Illustration A
Illustration B
Illustration C
3
F L O O R M O U N T S I N K
COLUMBIA SPECIFICATIONS
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
Hole Configurations
9” (228.6mm)
Front Side
16.75”(424.4mm)
27” (685.8mm)
10.5” (266.7mm)
45º
23” (584.2mm)
11.5”
(292.1mm)
11.5”
(292.1mm)
20.5”
(520.7mm)
17”
(431.8mm)
1.5” (38mm)
2” (51mm)
Top
20” (508mm) 20.5” (520.7mm)
2” (51mm)
1.5” (38mm)
.875” (22mm)
dia. holes (2)
6” (152.4mm)
10.5”
(266.7mm)
1.5” (38mm)
7.5” (191mm)
7.5”
(190.5mm)
7.5”
(190.5mm)
8”
(203.2mm)
3.25” (88.55mm)
2” drain hole
.5” R
(12.7mm)
.5” R (12.7mm)
Back Splash
Supply Line Detail
1/2” Male NPT
Hot
from Wall
Cold
from Wall
Floor Mounting Detail
1.5” Leg
Thickness
.75” From
Edge of Leg
to First Hole
.5” dia. Floor
Mounting Holes
9” on Center
Specyfikacje produktu
Marka: | Sani-Lav |
Kategoria: | Zlew |
Model: | 524F |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Sani-Lav 524F, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Zlew Sani-Lav
23 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
Instrukcje Zlew
- Zlew Teka
- Zlew Smeg
- Zlew Concept
- Zlew Nodor
- Zlew Hotpoint Ariston
- Zlew CDA
- Zlew Artusi
- Zlew Oliveri
- Zlew Franke
- Zlew Caple
- Zlew Kernau
- Zlew Foster
- Zlew Deante
- Zlew BLANCO
- Zlew Rangemaster
- Zlew Leisure
- Zlew Elkay
- Zlew Schock
- Zlew Roca
- Zlew Advance Tabco
- Zlew Laveo
- Zlew Tot Mate
- Zlew Kuchinox
- Zlew Shaws
Najnowsze instrukcje dla Zlew
14 Października 2024
13 Października 2024
13 Października 2024
13 Października 2024
13 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024