Instrukcja obsługi Rotel RKB-850 V2
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Rotel RKB-850 V2 (18 stron) w kategorii odbiornik. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/18
Owner’s Manual
Manuel de l’utilisateur
Bedienungsanleitung
Manual de Instrucciones
Gebruikershandleiding
Manuale di istruzioni
Instruktionsbok
Инструкция пользователя
RKB-850 / RKB-8100
RKB-D850 / RKB-D8100
Eight Channel Power Amplifiers
Amplificateurs de Puissance Huit Canaux
Achtkanal-Endstufe
Etapas de Potencia de Ocho Canales
Achtkanaals vermogensversterkers
Amplificatori finali a otto canali
8-kanals slutsteg
8-канальный усилитель мощности
2RKB Series Eight Channel Power Amplifiers
Notice
The RS232 connection should be handled by authorized persons only.
WARNING: There are no user serviceable parts inside. Refer all servicing
to qualified service personnel.
WARNING: To reduce the risk of fire or electric shock, do not expose the
unit to moisture or water. Do not expose the unit to dripping or splashing.
Do not place objects filled with liquids, such as vases, on the unit. Do
not allow foreign objects to get into the enclosure. If the unit is exposed
to moisture, or a foreign object gets into the enclosure, immediately
disconnect the power cord from the wall. Take the unit to a qualified
service person for inspection and necessary repairs.
Read all the instructions before connecting or operating the component.
Keep this manual so you can refer to these safety instructions.
Heed all warnings and safety information in these instructions and on
the product itself. Follow all operating instructions.
Clean the enclosure only with a dry cloth or a vacuum cleaner.
Do not use this unit near water.
You must allow a minimum 10 cm or 4 inches of unobstructed
clearance around the back of the unit.
Do not place the unit on a bed, sofa, rug, or similar surface that could
block the ventilation openings. If the unit is placed in a bookcase or
cabinet, there must be ventilation of the cabinet to allow proper cooling.
Keep the component away from radiators, heat registers, stoves, or any
other appliance that produces heat.
Rotel products are designed to comply with international
directives on the Restriction of Hazardous Substances
(RoHS) in electrical and electronic equipment and the
disposal of Waste Electrical and Electronic Equipment
(WEEE). The crossed wheelie bin symbol indicates
compliance and that the products must be appropriately
recycled or processed in accordance with these directives.
Important Safety Instructions
WARNING:
The rear panel power cord connector is the mains power
disconnect device. The device must be located in an open area that
allows access to the cord connector.
The unit must be connected to a power supply only of the type and
voltage specified on the side panel. (USA: 120 V/60Hz, EC: 230V/50Hz)
Connect the component to the power outlet only with the supplied
power supply cable or an exact equivalent. Do not modify the supplied
cable. A polarized plug has two blades, with one wider than the other. A
grounding plug has two blades plus a third grounding prong. These are
provided for your safety. Do not defeat grounding and/or polarization
safety provisions. If the supplied plug does not fit your outlet, please
consult an electrician for replacement of the obsolete outlet. Do not
use extension cords.
The main plug of the power cordset is a disconnect device of the apparatus.
In order to completely disconnect the apparatus from the supply mains,
the main plug of the power cordset should be unplugged from the mains
(AC) outlet. The power LED indicator will not be lit up to show the power
cord is unplugged. The disconnect device shall remain readily operable.
Do not route the power cord where it will be crushed, pinched, bent,
exposed to heat, or damaged in any way. Pay particular attention to the
power cord at the plug and where the cord exits the back of the unit.
The power cord should be unplugged from the wall outlet during a
lightning storm or if the unit is to be left unused for a long period
of time.
This apparatus shall be connected to a main socket outlet with a
protective earth connection.
Use only accessories specified by the manufacturer.
Use only with a cart, stand, rack, bracket or shelf system recommended
by Rotel. Use caution when moving the unit in a stand
or rack to avoid injury from a tip-over.
Use Class 2 wiring for speaker connections to ensure
proper installation and minimize the risk of electrical shock.
Immediately stop using the component and have it inspected and/
or serviced by a qualified service agency if:
• The power supply cord or plug has been damaged.
• Objects have fallen or liquid has been spilled into the unit.
• The unit has been exposed to rain.
• The unit shows signs of improper operation.
• The unit has been dropped or damaged in any way.
3
English
1
ROTEL RKB-D850/ RKB-D8100
ROTEL RKB-850/ RKB-8100
2
3 4
6 7 8
5
3 4 5
6 7 8
Figure 1: Controls and Connections
Figure 1 : Commandes et branchements
Figure 1: Bedienelemente und Anschlüsse
Figura 1: Controles y Conexiones
Afbeelding 1: Bedieningselementen en aansluitingen
Figura 1: Controlli e connessioni
Figur 1: Kontroller och kontakter
Рисунок 1: Органы управления и разъемы
Specyfikacje produktu
Marka: | Rotel |
Kategoria: | odbiornik |
Model: | RKB-850 V2 |
Kolor produktu: | Czarny |
Wbudowany wyłącznik: | Tak |
Częstotliwość wejściowa AC: | 60 Hz |
Napięcie wejściowe AC: | 120 V |
Wysokość produktu: | 97 mm |
Szerokość produktu: | 430 mm |
Głębokość produktu: | 424 mm |
Waga produktu: | 9300 g |
Technologia łączności: | Przewodowa |
Przeznaczenie: | Przedstawienie/scena |
Pobór mocy w trybie czuwania: | 0.5 W |
Kanały wyjścia audio: | 8.0 kan. |
Pobór mocy: | 150 W |
Wyście mocy ac: | Tak |
Moc szczytowa na kanał: | 50 W |
Klasa wzmacniacza: | D |
Współczynnik zawartości harmonicznych: | 0.08 % |
Stosunek sygnału do szumu: | 108 dB |
Zasięg częstotliwości: | 10 - 100000 Hz |
Czułość wejścia: | 600 mV |
Impedancja wejściowa: | 100000 Ω |
Pojemność stelaża: | 2U |
Przesłuch (1 kHz): | 60 dB |
Współczynnik tłumienia: | 150 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Rotel RKB-850 V2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje odbiornik Rotel
29 Czerwca 2024
29 Czerwca 2024
29 Czerwca 2024
29 Czerwca 2024
29 Czerwca 2024
29 Czerwca 2024
29 Czerwca 2024
29 Czerwca 2024
29 Czerwca 2024
29 Czerwca 2024
Instrukcje odbiornik
- odbiornik Yamaha
- odbiornik Pioneer
- odbiornik Plantronics
- odbiornik Technics
- odbiornik Onkyo
- odbiornik Edision
- odbiornik Bose
- odbiornik Zgemma
- odbiornik StarTech.com
- odbiornik Crestron
- odbiornik Behringer
- odbiornik Medion
- odbiornik Tangent
- odbiornik Boss
- odbiornik Peiying
- odbiornik Jensen
- odbiornik Blaupunkt
- odbiornik Metra
- odbiornik Line 6
- odbiornik Manhattan
- odbiornik Strong
- odbiornik Denon
- odbiornik Block
- odbiornik Phoenix Gold
- odbiornik Audac
- odbiornik Kenwood
- odbiornik NuPrime
- odbiornik Alpine
- odbiornik Focusrite
- odbiornik Auna
- odbiornik Vimar
- odbiornik Renkforce
- odbiornik Audiotec Fischer
- odbiornik Pro-Ject
- odbiornik Pyle
- odbiornik Marantz
- odbiornik Sennheiser
- odbiornik Chord
- odbiornik Fosi Audio
- odbiornik Musical Fidelity
- odbiornik Peavey
- odbiornik ART
- odbiornik NAD
- odbiornik Harman Kardon
- odbiornik Aiwa
- odbiornik JL Audio
- odbiornik AKAI
- odbiornik ICOM
- odbiornik Sunfire
- odbiornik Hifonics
- odbiornik Focal
- odbiornik DBX
- odbiornik Omnitronic
- odbiornik Hama
- odbiornik McIntosh
- odbiornik FSR
- odbiornik Ground Zero
- odbiornik Power Dynamics
- odbiornik Rockford Fosgate
- odbiornik Monacor
- odbiornik KanexPro
- odbiornik Kopul
- odbiornik BZBGear
- odbiornik Rupert Neve Designs
- odbiornik Key Digital
- odbiornik Ram Audio
- odbiornik Whirlwind
- odbiornik Music Hall
- odbiornik Apantac
- odbiornik Sonance
- odbiornik Devialet
Najnowsze instrukcje dla odbiornik
10 Lipca 2024
8 Lipca 2024
7 Lipca 2024
30 Czerwca 2024
28 Czerwca 2024
28 Czerwca 2024
28 Czerwca 2024
27 Czerwca 2024
27 Czerwca 2024
23 Czerwca 2024