C18 Multiuser Wall Control
With the C18 Multiuser Wall Control, commands (IR triggers) can be sent to the Multiuser
system that are stored in the Multiuser Server. The function is defined in the Configurator
itself. In addition, a different behaviour can be defined between a short and a long
keystroke.
Via the integrated IR receiver (to the left of the power button), infrared codes (RC5) can be
received from IR remote controls and forwarded to the Multiuser System for IR triggers.
With the help of the DIL switches on the back of the wall-mounted keypad, different RC5
addresses can be selected in case of IR conflicts with other remote controls/devices.
Command overview
Code page option for C18 wall-mounted keypad available from SW version 1.00 onwards
** RC5 code is combined with current user/source address, i.e. if user 2 (address 21) was selected last, e.g. the volume_up
command is also assigned address 21 and an RC5 command [21] [16] is sent.
Checking of RC5 command
The defined RC5 codes can be checked through the display on the Multiuser amplifier M30 or V219. The infrared mode
can be selected with its Setup button, the received signals from the IR Link inputs can be detected and its RC5 address and
command can be displayed.
IR display of the Multiuser amplifier M30 or V219
DIL switch
With the introduction of SW version 218-2 1.00 (Multiuser Programmer Software), there is a code page option for the C18
Multiuser Wall Control. 4 different code pages can be selected via DIL switches 3 and 4 on the back of the C18 wall keypad.
To do this, dismantle the wall control and remove the plastic cover on the back. The desired code page can now be set
with a small screwdriver. Please observe the current ESE regulations when the cover is open so as not to damage the
electronics.
Button
Description
Code
Page 1
Code
Page 2
Code
Page 3
Code
Page 4
User Favorit 1
Short keystroke: last favorit of User 1
L keystrokeong : favorit no. 1 User 1 of
[17] [63]
[24] [63]
[25] [63]
[26] [63]
User Favorit 2
Short keystroke: last favorit of User 2
Long keystroke: favorit . 1 no of User 2
[20] [63]
[24] [55]
[25] [55]
[26] [55]
User 1
Select User 1
[07] [63]
[24] [56]
[25] [56]
[26] [56]
User 2
Select User 2
[21] [63]
[24] [57]
[25] [57]
[26] [57]
Local Input
Select local analogue input of the user
[19] [63]
[24] [51]
[25] [51]
[26] [51]
Track_down
[ ] [ ] ** 33
[24] [19]
[25] [19]
[26] [19]
Track_up
[ ] [ ] ** 32
[24] [18]
[25] [18]
[26] [18]
Volume_down
[ ] [ ] ** 17
[24] [21]
[25] [21]
[26] [21]
Volume_up
[ ] [ ] ** 16
[24] [20]
[25] [20]
[26] [20]
Power Off
Short keystroke: switch-off room
Long keystroke: switch-off the complete system
[ ] [ ] ** 12
[24] [39]
[25] [39]
[26] [39]
RC5-Codes C18 Multiuser Wall Remote
Cabeling
The C18 wall control unit is connected to the Multiuser amplifier via a 3-pole screwable connector. When wiring, make
sure that the shielding of a CAT cable (S/FTP, F/FTP) is connected to the GND line on both sides. In addition, a pair of wires
for one signal should be connected together. Both measures increase the cable cross-section and thus reduce the voltage
drop in the cable. With this cabling variant, cable lengths of up to 100 m can be realised. Alternatively, a data cable of type
U72 (1x4x0.5 mm2) can be used.
Parallel operation
In larger rooms, it may make sense to place two C18 wall-mounted keypads at different locations in the room. 2 C18s may
be operated in parallel, i.e. all 3 signal lines (GND, IR, VCC) are connected in parallel.
To avoid double commands when using remote controls, if both wall-mounted keypads could receive the IR signal, it is
recommended to deactivate the IR receiver for of the two C18 wall-mounted keypads. This is set via a DIL switch (DIL one
1) on the back of the wall-mounted keypad - see illustration above.
The IR link, including the trigger-out of the multiuser amplifier, may be loaded with a maximum of 80 mA. The nominal
current requirement of a C18 is 23 mA.
Technical Data
DIL
Function
Description
Factory setting
1
IR eye
Intern IR receiver [1]/ off [0] al on
O n
2
LED
LED on [1]/ off [0]
On
3 + 4
RC5 Code Pages
RC5 adress combination
00: Code Page 1
01: Code Page 2
10 : Code Page 3
11: Code Page 4
Off Off [00] +
Protection class IP20, dry installation (acc. with IEC 60529)
Ambient temperature Operation -5 °C to +45 °C
Storage: -25 °C to +70 °C
Connection type Screwable plug connector
3 x 0.15 - 1.50 m
DIL factory settings 1: IR on
2: LED on
3: Code page 1-4
4: Code page 1-4
Cable Installation cable S/FTP or F/FTP or
U72 ABG 1 x 4 x 0.5 mm² creened) (s
Maximum cable lengths Max. 100 m Multiuser amplifier M30 or V to 219
Power consumption 17 mA (passive) /
23 mA (button pressed)
Parallel operation Max. 2 wall-mounted keypads can be switched in parallel
Revox Deutschland GmbH | Am Krebsgraben 15 | D-78048 VS-Villingen| Tel.: +49 7721 8704 0 | info@revox.de | www.revox.com
Revox (Schweiz) AG | Eichwatt 5 | CH-8105 Regensdorf | Tel.: +41 44 871 66 11 | info@revox.ch | www.revox.com
Revox Handels GmbH | Josef-Pirchl-Straße 38 | AT-6370 Kitzbühel | Tel.: +43 5356 66 299 | info@revox.at | www.revox.com
© Copyright 2023 Revox Group. All Rights Reserved
Technische Änderungen vorbehalten.
Manual-C18 m2-en
VCC + =
IR = IR
GND = -


Specyfikacje produktu

Marka: Revox
Kategoria: nieskategoryzowany
Model: V218

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Revox V218, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Revox

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Asko

Asko DBI644MIB.S.TW/1 Instrukcja

28 Października 2024
Asko

Asko DFS233IB.S.TW/1 Instrukcja

28 Października 2024
Emko

Emko EZM-9920 Instrukcja

27 Października 2024
Emko

Emko ESM-3712-H Instrukcja

27 Października 2024
Emko

Emko ATS-10 Instrukcja

27 Października 2024
Emko

Emko EAOM-11.2 Instrukcja

27 Października 2024
Emko

Emko EPM-3790 Instrukcja

27 Października 2024
Emko

Emko EPM-7790 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux IAN 108340 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux HG06009A-BS Instrukcja

27 Października 2024