OWNER MANUAL
TTS36-A HIGH OUTPUT ACTIVE
SUBWOOFER
3
ENGLISH
ITALIANO
LANGUAGE
4
13
4
ENGLISH
1. All the precautions, in particular the safety ones, must be read with special attention, as
they provide important information.
2. POWER SUPPLY FROM MAINS
a. The mains voltage is sufficiently high to involve a risk of electrocution; install and
connect this product before plugging it in.
b. Before powering up, make sure that all the connections have been made correctly and
the voltage of your mains corresponds to the voltage shown on the rating plate on the
unit, if not, please contact your RCF dealer.
c. The metallic parts of the unit are earthed through the power cable. An apparatus with
CLASS I construction shall be connected to a mains socket outlet with a protective
earthing connection.
d. Protect the power cable from damage; make sure it is positioned in a way that it
cannot be stepped on or crushed by objects.
e. To prevent the risk of electric shock, never open this product: there are no parts inside
that the user needs to access.
f. “POWER ON switch is a disconnecting device from AC main power and must be
easely accessible after the installation and during the using of equipment.
3. Make sure that no objects or liquids can get into this product, as this may cause a short
circuit.
This apparatus shall not be exposed to dripping or splashing. No objects filled with liquid,
such as vases, shall be placed on this apparatus. No naked sources (such as lighted candles)
should be placed on this apparatus.
4. Never attempt to carry out any operations, modifications or repairs that are not expressly
described in this manual.
Contact your authorized service centre or qualified personnel should any of the following
occur:
- The product does not function (or functions in an anomalous way).
- The power cable has been damaged.
- Objects or liquids have got in the unit.
- The product has been subject to a heavy impact.
5. If this product is not used for a long period, disconnect the power cable.
6. If this product begins emitting any strange odours or smoke, switch it off immediately
and disconnect the power cable.
7. Do not connect this product to any equipment or accessories not foreseen.
For suspended installation, only use the dedicated anchoring points and do not try to hang
this product by using elements that are unsuitable or not specific for this purpose. Also
check the suitability of the support surface to which the product is anchored (wall, ceiling,
structure, etc.), and the components used for attachment (screw anchors, screws, brackets
not supplied by RCF etc.), which must guarantee the security of the system / installation
over time, also considering, for example, the mechanical vibrations normally generated by
transducers.
To prevent the risk of falling equipment, do not stack multiple units of this product unless
this possibility is specified in the user manual.
8. RCF S.p.A. strongly recommends this product is only installed by professional
qualified installers (or specialised firms) who can ensure correct installation
and certify it according to the regulations in force.
The entire audio system must comply with the current standards and regulations
regarding electrical systems.
9. Supports and trolleys
The equipment should be only used on trolleys or supports, where necessary, that are
SAFETY
PRECAUTIONS
IMPORTANT
5
ENGLISH
recommended by the manufacturer. The equipment / support / trolley assembly must be
moved with extreme caution. Sudden stops, excessive pushing force and uneven floors may
cause the assembly to overturn.
10. There are numerous mechanical and electrical factors to be considered when installing
a professional audio system (in addition to those which are strictly acoustic, such as sound
pressure, angles of coverage, frequency response, etc.).
11. Hearing loss
Exposure to high sound levels can cause permanent hearing loss. The acoustic pressure level
that leads to hearing loss is different from person to person and depends on the duration
of exposure. To prevent potentially dangerous exposure to high levels of acoustic pressure,
anyone who is exposed to these levels should use adequate protection devices. When a
transducer capable of producing high sound levels is being used, it is therefore necessary
to wear ear plugs or protective earphones. See the manual technical specifications to know
the maximum sound pressure level.
IMPORTANT NOTES
To prevent the occurrence of noise on line signal cables, use screened cables only and avoid
putting them close to:
- Equipment that produces high-intensity electromagnetic fields.
- Power cables.
- Loudspeaker lines.
OPERATING PRECAUTIONS
- Place this product far from any heat sources and always ensure an adequate air
circulation around it.
- Do not overload this product for a long time.
- Never force the control elements (keys, knobs, etc.).
- Do not use solvents, alcohol, benzene or other volatile substances for cleaning the
external parts of this product.
IMPORTANT NOTES
Before connecting and using this product, please read this instruction manual carefully and
keep it on hand for future reference. The manual is to be considered an integral part of
this product and must accompany it when it changes ownership as a reference for correct
installation and use as well as for the safety precautions. RCF S.p.A. will not assume any
responsibility for the incorrect installation and / or use of this product.
WARNING: to prevent the risk of fire or electric shock, never expose this product to rain
or humidity.
OPERATING
PRECAUTIONS
IMPORTANT NOTES
IMPORTANT NOTES
WARNING
6
ENGLISH
INNOVATION
TT+ HIGH DEFINITION
TOURING AND THEATRE
INTEGRATION
INTENSITY
TTS36-A,
HIGH OUTPUT
SUBWOOFER
TT+ HIGH DEFINITION TOURING AND THEATRE
RCF TT+ represents another prominent chapter in the long history of RCF Sound Systems.
Whether a speaker system is designed for live sound or large concert situations as well as permanent
installed theatre sound applications, the paying customer now expects a level of audio delity and
intelligibility of such a standard unsurpassed by previous generations.
This requirement has fostered the need for Audio Professionals to be able to offer a range of
speaker systems combined with dedicated Processing and Amplification Technologies that are
superior in Acoustic Performance and Control Technology.
RCF TT+ offers ready to use solutions and tools in true active high denition speaker systems.
INNOVATION INTEGRATION INTENSITY
Innovation. Our research and engineering faculty can today offer innovative projects with
finite control of each detail, from the loudspeaker voice coil wire to the highly efficient
extended dynamic amplifier topology. There are many different ingredients that go into
creating quality products and systems. These include computer aided simulation software
to assist the understanding of transducer behaviour and amplifier operation and the
relationship of dynamics and transient response. RCF utilise over thirty state of the art
software packages to identify magnetic circuits, voice coil dynamics, suspension linearity,
horn dispersion simulation, crossover filters, amplifier thermal behaviour etc.
Integration. RCF is one of only a few loudspeaker manufacturers worldwide who have
the ability to completely design and manufactures transducers, speaker systems and
amplification and control electronics. Our 50 plus years heritage in Audio combined with
our state of the art research and development and manufacturing processes allows us to
seamlessly integrate all the ingredients to design and build TT+.
Intensity. The design philosophy for the new TT+ series is based upon offering the sound
engineer solutions and tools that are ready to use. Key factors are the ability to sustain very
high power with highly efficient sound pressure levels. Intense sound levels are created with
extremely high definition and extended dynamic range. Modern construction materials result
in mechanical weight ratios that are light for practical flying and portability.
TTS36-A, HIGH OUTPUT SUBWOOFER
The TTS36-A is a high power, high output active subwoofer system that sets a new standard in
the touring and theatre sound reinforcement. Each transducer has been specifically designed for
the application. The woofer provides large excursion and very light weight.
The TTS36-A two 18” woofers features:
- lightweight, high force, neodymium magnet assembly.
- 115 mm diameter, 33 mm length, inside-outside copper voice coil.
- Silicon reinforced double spiders.
- Carbon fiber doped, water resistant treated cone.
- Complex ventilation system for minimum power compression.
The TTS36-A input section provides:
- IN/OUT XLR connectors.
- Crossover Output XLR connector.
- System sensitivity control (linear potentiometer) (-2 dBu ~ +10 dBu).
- Crossover set-up (60 Hz - 80 Hz).
- Low frequencies high pass set-up (30 Hz - 45 Hz).
- Delay set-up rotary switch.
- Cardioid set-up switch.
- By-pass switch.
- RDNet input output Ethercon connectors.
- 4 status LEDs.
PRODUCT
INFORMATIONS
7
ENGLISH
MAIN SIGNAL XLR INPUT (BAL/UNBAL). The system accept female XLR input connectors
and line-level signals from a mixing console or other signal source.
SIGNAL LINK XLR OUTPUT. The output XLR male connector provides a loop trough for
speakers daisy chaining.
XOVER SIGNAL OUTPUT. The output XLR male connector provides a crossover high passed
signal (24 dB/octave) for satellites speakers.
INPUT SENSITIVITY. Controls the overall signal level at the input to the power amplifier. The
control ranges from + 10 dBu (maximum attenuation) to the –2 dBu sensitivity (maximum input
gain). The centre detent is +4 dBu (nominal level required to drive the amplifier at maximum
power).
XLOW CUT 30/45 Hz. This switch provides an high pass 24 dB/octave filtering at 30 or 45
Hz. This is really useful for indoor situations (no very low frequencies that can create resonant
sound) or when all the power shall be used in the 45 Hz - 100 Hz range.
XOVER 60/100 HZ. Provides 24 dB/octave low-pass filtering at 80 Hz if released, at 110 Hz
if pressed. The same crossover frequency in high-pass is available from XOVER OUTPUT XLR.
TIME DELAY ENCODER. This encoder provides a time delay setting expressed in meters.
TIME DELAY DISPLAY. Display the time delay setting.
POWER INDICATOR. Power on indicator. When the power cord is connected and the power
switch is turned on this indicator lights green.
STATUS INDICATOR. The status indicator blink orange if the main amplifier or power supply
REAR
PANEL
The TTS36-A amplifier section features:
- 2 x 2000 Watt digital amplifiers.
- PFC circuit.
- 7 x cooling speed controlled fans.
- Powercon AC input connector.
- Vibrostop floating aluminum panel.
1
2
3
4
5
6
7
8
9
10
6
12
11
10
9
23
17
18
15 16
8
4
5
1
13
7
14
8
ENGLISH
is in faulty condition. If the status indicator lights orange, switch off the amplifier and call the
closest RCF SERVICE CENTRE.
SIGNAL INDICATOR. The signal indicator lights green if there is signal present on the main
XLR input.
LIMITER INDICATOR. The amplifier has a built in compressor/limiter circuit to prevent
clipping of the amplifiers or overdriving the transducers.
When the compressor is active the led is blinking yellow. When the soft clipping circuit is active
the LED blinks orange. It is okay if the limit LED blinks occasionally. If the LED blinks frequently
or lights continuously, turn down the signal level. The amplifier has a built in RMS limiter. If the
RMS limiter is active the LED lights red. The RMS limiter has the purpose to prevent damages
the transducers. The speaker shall never be used with the limit indicator red, continuously.
Continuous operation with the RMS protection active can cause damages to the speaker.
CARDIOID SET-UP SWITCH. This switch provides a special equalisation and delay setting
to create a cardioid pattern when the system is used in conjunction with two other TTS56-A
modules.
BY PASS SWITCH. Pressing this switch it is possible to by-pass the RDNet user setting
preloaded on the module.
DATA INPUT ETHERCON CONNECTOR. RDNet Input CAT5 Ethercon connector.
DATA LINK ETHERCON CONNECTOR. RDNet Link CAT5 Ethercon connector.
LINK LED. This green led is on if the module is addressed from the RDNet controller.
ACTIVE LED. This green led is blinking if the RDNet communication is active.
POWER MAIN SWITCH. The power switch turns the AC power ON and OFF. Make sure that
the sensitivity is set to + 10 dBu when you turn on the speaker.
AC POWERCON RECEPTACLE. RCF TT+ series uses a POWERCON locking 3-pole AC
mains. Always use the specific power cord provided in the package.
11
12
13
14
15
16
17
18
19
20
19 20
9
ENGLISH
BEFORE TURNING ON
THE SPEAKER
TIME DELAY SETTING
The XLR connectors use the following AES standard:
PIN 1 = GROUND (SHIELD)
PIN 2 = HOT (+)
PIN 3 = COLD (-)
At this point you can connect the power supply cable and the signal cable, but before
turning on the speaker make sure that the volume control is at the minimum level (even
on the mixer output). It is important that the mixer is already ON before turning on the
speaker. This will avoid damage to the speakers and noisy “bumps” due to turning on parts
on the audio chain. It is a good practice to always turn on speakers at last and turn them
off immediately after the show.
Now you can turn ON the speaker and adjust the volume control to a proper level.
The delay is expressed in meters. The delay resolution is 0.1 up to 10 meters and 1 from
10 to 20 meters.
To set the system time delay push the delay encoder and rotate it until the wanted setting
is displayed. Push the encoder again to confirm the setting.
It is possible to create subwoofer cardioid systems using .groups of three modules
A group is made of three modules, the group shall be made as follow:
- 2 modules pointing in forward direction, cardioid switch released.
- 1 module pointing in backward direction, cardioid switch pressed.
- All 3 modules shall have the same settings (SYSTEM DELAY, SENSITIVITY, X-LOW
CUT, X-OVER,…).
HOT GND
BAL. XLR
COLD
CONNECTIONS
FRONTREAR
SIDE VIEW FRONT
CARDIOID
SET-UP
10
ENGLISH
RDNet CONNECTION
The system is equipped with an RDNet connection on board. Using an RDNet controller
unit it is possible to:
- receive status information from the system (amplifiers status, signal levels, system
settings,…)
- send commands to the system (mute, solo, change sensitivity, change setting, set user
eq,…)
See the RDNet user manual for details.
RDNet BY-PASS SWITCH
When the RDNet is present and the RDNet LINK LED is green the controller takes control
over the module independently of the BY-PASS SWITCH position.
When the , the BY-PASS switch act as follow:RDNet is not present
- BY-PASS SWITCH pressed (LED ON): the system bypass the input board and reads
the RDNet user settings ( ).last configuration saved
- BY-PASS SWITCH released (LED OFF): the system and bypass reads the input board
the user setting eventually loaded ion the speaker (last configuration eventually saved).
TTS36-A DEFAULT CONFIGURATION
The TTS36-A factory default configuration (the configuration that the system reads if
the BY-PASS switch is pressed) is the following:
Sensitivity +4 dBu
High pass 30 Hz
Low pass 90 Hz
Cardioid OFF
Delay 0
Bypass OFF
User filters ALL FLAT
If the user set with RDNet a new configuration, the new configuration will be recalled
when the BY-PASS switch is pressed.
BY-PASS SWITCH RDNet BY-PASS LED FUNCTION
ON ON ON Reads RDNet settings
OFF ON OFF Reads RDNet settings
ON OFF ON Reads last saved used configuration
OFF OFF OFF Reads input panel
RDNet
RDNet CONNECTION
RDNet BY-PASS SWITCH
TTS36-A
DEFAULT CONFIGURATION


Specyfikacje produktu

Marka: RCF
Kategoria: głośnik
Model: TTS36-A

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z RCF TTS36-A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje głośnik RCF

RCF

RCF HDL 36-AS Instrukcja

12 Stycznia 2025
RCF

RCF NXL 14-A Instrukcja

2 Stycznia 2025
RCF

RCF HD 10-A MK5 Instrukcja

29 Grudnia 2024
RCF

RCF MR 40 Instrukcja

13 Października 2024
RCF

RCF C3108-126 Instrukcja

7 Października 2024
RCF

RCF NX 945-A Instrukcja

4 Października 2024
RCF

RCF C3110-96 Instrukcja

28 Września 2024
RCF

RCF S 5012 Instrukcja

23 Września 2024
RCF

RCF ART 935-A Instrukcja

17 Września 2024

Instrukcje głośnik

Najnowsze instrukcje dla głośnik