Instrukcja obsługi PowerWalker VI 1000 MS

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla PowerWalker VI 1000 MS (2 stron) w kategorii zasilacz UPS. Ta instrukcja była pomocna dla 14 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
Inspection
The following items are inside the box:
UPS unit User Manual
Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
re-pack the unit and return it to the place of purchase.
Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to
charge inside battery. For best result, charge the battery for 6
hours prior to initial use.
Connect Modem/Phone Line/Data Line
(only for the model with TVSS port)
This UPS protects a single line (1 in/1 out) phone, modem, or fax
machine from surges when connected through the UPS. Plug
incoming Internet line into the “IN” socket. Use one more Internet
line cable in the “OUT” socket and plug one other end to the
modem input socket.
*Outlet type can be Type F (CEE 7/3) Type E (CEE 7/5), , Type G
(BS 1363) and IEC.
LCD display or LED indicators (Please check LED or LCD
section for the details)
Power switch
Battery backup outlets
Surge- protected outlets
USB port (option)
Modem/phone/network surge protection (option)
USB charger port (option)
AC input power cord
AC input with fuse (only for IEC model)
Circuit breaker
Plug in Equipment
There are two types of output receptacles: Battery Backup Outlet
and Surge-protected Outlet.
Battery Backup Outlets
Connect computer and monitor to the "Battery Backup outlet" s.
These outlets provide battery backup, EMI filtering, line
conditioning, and surge protection. Battery power is automatically
provided in case of power failure.
NOTE: Make sure that the UPS is powered on to protect all
important devices from data loss during power failure.
CAUTION: NEVER connect a laser printer or scanner to the
battery backup outlets of UPS. The equipment may draw
significantly power to overload the UPS.
Surge-Protected Outlets
Connect a printer, fax machine, or scanner to the “Surge-
protectedo utlets. These outlets do not provide power during
power failure.
Connect Com. Port and Install Software
(only for the model with USB port)
Connect one end of the USB cable to PC and the other to the USB
port at the rear of the UPS.
Download the latest version of ViewPower software from
http://software.powerwalker.com to your hard drive. Follow on-
screen instructions to complete the software installation.
Turn On/Off the UPS
To turn on the UPS unit, press the power switch lightly. Then, the
LED or LCD will light up. To turn off the UPS unit, press the power
switch again. Then, display will shut off.
Input voltage Load level indicator, flashing
Output voltage indicates overload
AC mode indicator Battery capacity indicator,
Battery mode indicator flashing indicates low battery
LED
Alarm
UPS Status
Green Off
The mains is normal and
UPS is operated
normally.
Yellow
Sounding every
10 seconds
Power failure occurs and
UPS is on battery mode.
Yellow
Sounding every
second
Low battery
Green
Off
UPS is off.
Red
Continuously
sounding
UPS fault
● ○LED on LED Off LED flashing
LCD Display optional
LED Indicators
INSTALLATION
PRODUCT OVERVIEW
This UPS utilizes voltage that may be hazardous. Do not attempt to
disassemble the unit. The unit contains no user replaceable parts.
Only factory service personnel may perform repairs.
This pluggable type A equipment with battery already installed by the
supplier is operator installable and may be operated by laymen.
The mains socket outlet that supplies the UPS shall be installed near
the UPS and shall be easily accessible.
During the installation of this equipment it should be assured that the
sum of the leakage currents of the UPS and the connected loads does
not exceed 3.5mA.
-Connection to any other type of receptacle other than a two pole,
three-wire grounded receptacle may result in shock hazard as well as
violate local electrical codes.
In the event of an emergency, press the "OFF" button and disconnect
the power cord from the AC power supply to properly disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS. Do
not place beverages or any other liquid containing vessels on or near -
the unit.
This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive contaminants).
Avoid installing the UPS in locations where there is standing or running
water, or excessive humidity.
Do not plug the UPS input into its own output.
Do not attach a power strip or surge suppressor to the UPS.
- - Do not attach non computer related items, such as medical equipment,
life- support equipment, microwave ovens, or vacuum cleaners to UPS.
Do not dispose of batteries in a fire as they may explode.
MODEL
400
600
CAPACITY
400VA/240W
600VA/360W
Input Voltage
23 0VAC
Input Voltage Range
170 280VAC-
Output Voltage
Regulation
± 10 % (Bat. mode)
Transfer Time
Typical 6 ms, 10ms max.
Waveform
Simulated Sine Wave
Battery Type & No
12V/4.5Ahx1
12V/7 Ahx1
Charging Time
6-8 hours recover to 90% capacity
Dimension (DxWxH)
345 00 x 200 x 1 mm
Net Weight (kgs)
4 .2
5.1
Humidity
0- - -90% RH @ 0 40°C non condensing)
Noise Level
Less than 40dB
MODEL
8 00
10 00
CAPACITY
800VA/480W
1KVA/6 00W
Input Voltage
230VAC
Input Voltage Range
170 280VAC-
Output Voltage
Regulation
± 10 % (Bat. mode)
Transfer Time
Typical 6 ms, 10ms max.
Waveform
Simulated Sine Wave
Battery Type & No
12V/9 1 Ah x
12V/9 1 Ah x
Charging Time
6- hours recover to 90% capacity
Dimension (DxWxH)
345 00 x 200 x 1 mm
Net Weight (kgs)
5.8
6.4
Humidity
0- 0- -90% RH @ 40°C non condensing)
Noise Level
Less than 40dB
*Specifications are subject to change without notice.
A battery can present a risk of electrical shock and high short circuit
current. The following precautions should be observed when working
on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting
batteries terminal.
6) Determine if battery is inadvertently grounded. If inadvertently
grounded, remove source from ground. Contact with any part of a
grounded battery can result in electrical shock. The likelihood of such
shock can be reduced if such grounds are removed during installation
and maintenance.
- -Internal battery voltage is 12VDC.Sealed, lead acid, 6 cell battery.
Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions. Keep
unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and type of
sealed lead acid battery.-
Do not open or mutilate the battery or batteries. Release electrolyte is
harmful to the skin and eyes. It may be toxic.
Attention, hazardous through electric shock. Also with disconnection of
this unit from the mains, hazardous voltage still may be accessible
through supply from battery. The battery supply should be therefore
disconnected in the plus and minus pole at the connectors of the
battery when maintenance or service work inside the UPS is
necessary.
To reduce the risk of overheating the UPS, do not cover the UPS'
cooling vents and avoid exposing the unit to direct sunlight or installing
the unit near heat emitting appliances such as space heater or
furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
WARNING: This is a category C2 UPS product. In a residential
environment, this product may cause radio interference, in which case
the user may be required to take additional measures.
Problem
Possible Cause
Solutions
LED /LCD not
lit.
The UPS is not on.
Press the power switch
again to turn on the UPS.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Battery fault.
Replace the battery.
The UPS
always on
battery mode.
Power cord loose.
Re-plug the power cord.
The UPS
continuously
beeps.
Please check the fault
code for the details.
Please check the fault code
for the details.
Backup time
too short.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Overload.
Remove some unnecessary
loads. Before reconnecting
equipment, please verify
that the load matches the
UPS capability specified in
the specs.
Battery defect.
Replace the battery.
If any abnormal situations occur that are not listed above, please
call for service immediately.
SAFETY CAUTION
SAVE THESE INSTRUCTION-This manual contains important instructions that should be followed
during installation and maintenance of the UPS and batteries.
SPECIFICATIONS
TROUBLESHOOTING

Specyfikacje produktu

Marka: PowerWalker
Kategoria: zasilacz UPS
Model: VI 1000 MS
Kolor produktu: Czarny
Wysokość produktu: 100 mm
Szerokość produktu: 200 mm
Głębokość produktu: 345 mm
Waga produktu: 6400 g
Szerokość opakowania: 146 mm
Wysokość opakowania: 269 mm
Głębokość opakowania: 425 mm
Czas ładowania: 8 h
Poziom hałasu: 40 dB
Port USB: Tak
Napięcie operacyjne wejścia (maksymalne): 280 V
Pojemność baterii: 9 Ah
Ilość portów Ethernet LAN (RJ-45): 2
Zakres temperatur (eksploatacja): 0 - 40 °C
Zakres wilgotności względnej: 0 - 90 %
Układ: Kompaktowy
Kod zharmonizowanego systemu (HS): 85078000
Waga wraz z opakowaniem: 7000 g
Częstotliwość danych wejściowych: 50/60 Hz
Diody LED: Tak
Rodzaj chłodzenia: Pasywne
Port RS-232: 1
Liczba baterii: 1
Napięcie baterii: 12 V
Moc rzeczywista: 600 W
Wbudowany wentylator: Nie
Maksymalna możliwa do konfiguracji moc: 1 kVA
Napięcie operacyjne wejścia (minimalne): 170 V
Napięcie operacyjne wyjścia (maksymalne): 230 V
Napięcie operacyjne wyjścia (minimalne): 230 V
Wartość znamionowa udaru energii: 156 J
Funkcje ochrony przed przepięciami: Fax, Modem, Network, Telephone
Ilość gniazd sieciowych: 8 x gniazdo sieciowe
Typy wyjść AC: Typu F
Typowy czas podtrzymania przy połowie obciążenia: 1.2 min
Typowy czas podtrzymania przy pełnym obciążeniu: 0.1 min
Interfejs SCSI: RS-232
Ochrona przed nagłym wzrostem napięcia: Tak
Współczynnik mocy: 0.6
Interfejs szeregowy: Tak
Prąd ładowania: 2.1 A
Przebieg falowy: Sinus
Automatyczna regulacja napięcia (AVR): Tak
Regulacja napięcia wyjściowego: 10 %
Topologia UPS: Technologia line-interactive
Współczynnik mocy wyjściowej: 0.6

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z PowerWalker VI 1000 MS, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą