2
The BR50 Brad Nailer is a trigger-pull nailer designed to bring Powernail quality
and fl ooring expertise to a pneumatic brad nailer.
The BR50 is designed for use with brad fi nish nails in lengths of 5/8” to 2”.
The Model BR50 nails from 1/2” to 1-3/4” board and trim.
INTRODUCTION
INDEX
LIMITED WARRANTY
POWERNAIL® Company, Inc. warrants to its customer, and to the fi rst end-use purchaser
of POWERNAIL BR50 Brad Nailer purchased from an authorized POWERNAIL
distributor, that each serialized manufactured BR50 Brad Nailer by POWERNAIL®, for
a period of 12 months from the date of purchase; shall be free of defects in materials and
workmanship and will meet POWERNAIL’S specifi cations in effect at the time of product
shipment. POWERNAIL will repair or replace, at its option, any BR50 Brad Nailer that
does not conform to this warranty. Claims must be made no later than fi fteen (15) days after
the end of the warranty period. POWERNAIL will perform all repair or replacements itself
or through its authorized contractors. POWERNAIL is not responsible for shipping, labor
or other direct or indirect costs. Damage caused by abuse, misuse, unusual or excessive
wear is excluded. Repair or modifi cation of the Products by unauthorized parties will
void this warranty. The customer is responsible for returning Products to POWERNAIL
for verifi cation of nonconformance. Warranties for Products not manufactured by
POWERNAIL are limited to warranties provided to POWERNAIL by the manufacturer of
such product that are assignable to customer.
THESE WARRANTIES AND REMEDIES ARE EXCLUSIVE OF ALL OTHERS,
EXPRESS OR IMPLIED. THE WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR PURPOSE ARE EXPRESSLY EXCLUDED. IN NO EVENT SHALL
POWERNAIL’S LIABILITY FOR A WARRANTY CLAIM EXCEED THE PRICE PAID
TO POWERNAIL FOR THE NONCONFORMING PRODUCT, REGARDLESS OF THE
FORM OR BASIS OF THE CLAIM OR CAUSE OF ACTION.
Index..................................... 2
Warranty............................... 2
Safety Instructions................ 3
Operating the tool................. 4-6
Air Supply............................. 5
Loading fasteners................. 6
Clearing a jam...................... 7
Safety Labels........................ 7
Troubleshooting Chart.......... 9
Parts List........................ 10
Schematic........................ 11
Phone Support..................... 12
Web Site.............................. 12
Powernail Company Info..... 12
SAFETY INSTRUCTIONS
3
When operating this Nailer, the operator and others in the work area should ALWAYS wear approved
SAFETY GLASSES, with front and side eye protection. Eye protection will help guard against fl ying
nails and debris, which could cause severe eye injury.
EAR PROTECTION should be used to prevent hearing damage when there are high noise levels
in the work area. ALWAYS use ear plugs with a noise reduction rated at 29 db or higher at a
construction site.
Noise characteristic values in accordance with ENxx1:
A-weighted single-event sound pressure level at operator’s position: LPA, ls94dBA
A-weighted single sound pressure level:LpA,ls,lm89dBA
Vibration characteristic values in accordance with ISO 8662, PART II
Weighted root mean square acceleration 3.2m/s²
Always DISCONNECT THE AIR SUPPLY before making any adjustments, repairing, clearing jams or when
the Nailer is not in use. Do not use on scaffolding or ladders and disconnect nailer from air supply when
transporting
between installation areas.
Never attach the female end of a quick disconnect to the Nailer. This will trap air inside the Nailer and permit it
to be discharged. Only the unrestricted male connection should be attached to the Nailer.
Nailer requires an air source that can continuously deliver 70 to 100 psi at 3-1/2 cubic feet of air per minute
for operation.
Normal air pressure should not exceed 100 psi or damage to the Nailer and seals may occur. Excess air
pressure can cause the Nailer to explode.
To prevent fi re or explosion, use only regulated compressed air—do not use bottled gases of any kind (no
oxygen or combustible gasses) to power this Nailer.
Nailer is intended for use installing wood fl ooring and is not to be used for purposes not specifi ed in the
operations manual.
Do not use any nails other than 18 gauge straight brad fi nish nails which are designed specifi cally for your
nailer.
Use only Powernail replacement parts in the repair or maintenance of this nailer. Parts or repair services are
available from the manufacturer or from agents authorized by the manufacturer. Repairs should be carried out
only by trained service personel in the fi eld of fastener driving tools who will observe proper safety controls
while performing maintenance. Service personel should be qualifi ed to assess the safe working condition of
fastener driving tools.
Always make sure nailer is empty of nails before connecting an air hose, so as to prevent any accidental
discharge from occurring. ONLY CONNECT AIR TO AN UNLOADED NAILER.
Do not depress the trigger when loading. If the fasteners are jammed, disconnect the tool from the air supply
before you remove the jammed nails.
Never place any part of the body in the discharge path of the Nailer when air is connected to the
Nailer. Never point the tool at yourself or others, even if the tool is not loaded. For safety, keep out
of reach of children. Never leave the Nailer unattended while it is connected to an air supply.
Do not fi re into hard materials or attempt to use on hard or brittle material such as concrete, steel
or tile. Before using this tool, carefully check that all parts are working correctly. Do not use the tool if it is not
operating correctly, check for causes and adjust as necessary for proper operation. When not in use, the tool
should be cleaned, fully assembled and then stored in a dry location. This will extend the life of the tool and
reduce any oxidation.
Specyfikacje produktu
Marka: | POWERNAIL |
Kategoria: | kompresor |
Model: | BR50 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z POWERNAIL BR50, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje kompresor POWERNAIL
13 Września 2024
12 Września 2024
10 Września 2024
10 Września 2024
8 Września 2024
Instrukcje kompresor
- kompresor Livoo
- kompresor Ultimate Speed
- kompresor Yato
- kompresor Parkside
- kompresor Global
- kompresor Toolcraft
- kompresor Festool
- kompresor Stanley
- kompresor Boss
- kompresor Scheppach
- kompresor DeWalt
- kompresor Einhell
- kompresor Hyundai
- kompresor Silverline
- kompresor Makita
- kompresor Carel
- kompresor Ozito
- kompresor Draper
- kompresor DEDRA
- kompresor Biltema
- kompresor CMI
- kompresor Osram
- kompresor Trotec
- kompresor Meec Tools
- kompresor Güde
- kompresor Bavaria
- kompresor Zipper
- kompresor PreSonus
- kompresor Airpress
- kompresor DURO PRO
- kompresor Unimac
- kompresor Westfalia
- kompresor Eventide
- kompresor Lindell Audio
- kompresor Aerotec
- kompresor Ferm
- kompresor Nilfisk
- kompresor Hitachi
- kompresor Herkules
- kompresor Craftsman
- kompresor Fieldmann
- kompresor PowerPlus
- kompresor Vonroc
- kompresor HiKOKI
- kompresor Workzone
- kompresor Proviel
- kompresor OKAY
- kompresor Porter-Cable
- kompresor Metabo
- kompresor SPL
- kompresor WilTec
- kompresor Cocraft
- kompresor Proline
- kompresor Pansam
- kompresor Auto Joe
- kompresor Sun Joe
- kompresor Tacklife
- kompresor Senco
- kompresor Steren
- kompresor Power Craft
- kompresor Laica
- kompresor Topcraft
- kompresor Outbac
- kompresor Duro
- kompresor Truper
- kompresor Abac
- kompresor Eufab
- kompresor Holzmann
- kompresor Avantco
- kompresor Arebos
- kompresor Sthor
- kompresor Anova
- kompresor Narvon
- kompresor Freeman
- kompresor Airman
- kompresor Merlin
- kompresor Pretul
- kompresor Pro-Lift
- kompresor Aomni
- kompresor Numax
- kompresor Full Boar
- kompresor TOOLMATE
- kompresor California Air Tools
- kompresor Ilsco
- kompresor Hulk Power
- kompresor Cartrend
- kompresor MSW
- kompresor Creemers
- kompresor Hamron
- kompresor Robust
- kompresor Alphacool
- kompresor ExelAir
- kompresor TJM
- kompresor Prowork
- kompresor TAURUS Titanium
Najnowsze instrukcje dla kompresor
15 Października 2024
15 Października 2024
13 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024