SU750RTXLCD2U
SU1000RTXLCD2U
SU1500RTXLCD2U
SU2000RTXLCD2U
SU2200RTXLCD2U
SU3000RTXLCD3U
Quick
Start Guide—
Page 10
SmartOnline®
Single-Phase Rack-Mount On-Line UPS Systems
with Built-in LCD Monitoring & Control Screen
Not suitable for mobile applications.
1. Overview 2
Parts List 2
Additional Accessory Options 2
Model Specific Accessories 2
2. Important Safety Instructions 3
3. Installation 4
Rack Mounting 4
Tower Mounting 6
4. Features 7
Front Panel Controls 7
Rear Panel Features 8
5. Basic Connection and Start-Up 10
Quick Start Guide 10
Optional Connections 11
6. Operation 13
Modes of Operation 13
LCD Informational Screens 16
UPS Setup Overview 18
Using PowerAlert 18
Using Front Panel LCD Interface 18
7. Troubleshooting 25
8. Internal Battery Replacement 26
9. Storage and Service 30
10. Product Registration and 30
Regulatory Compliance
Español 31
Français 61
NOTE: External battery pack options require configuration using front panel LCD interface or via Tripp Lite’s EXTERNAL BATTERY CONFIGURATION software.
See page 23 for more information if you are connecting external batteries to this UPS.
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2019 Tripp Lite. All rights reserved.
WARRANTY REGISTRATION
Register your product today and be
automatically entered to win an ISOBAR
surge protector in our monthly drawing!
tripplite.com/warranty
2
Overview
Tripp Lite SmartOnline Rack-Mount UPS Systems with interactive LCD interface feature on-line,, double-conversion UPS protection with
full-time sine wave output and zero transfer time suitable for all advanced networking applications. Each system provides long running
battery support with optional extended-run and SNMP/Web communications ability. Built-in interfaces include USB, DB9 serial and
Emergency Power Off (EPO). The interactive front panel LCD screen provides detailed UPS status, preset and control options. An optional
economy mode setting reduces power consumption and BTU heat output.
Parts List
UPS System Bolt-On Mounting Ears (2) 4-Post Rail Kit* PowerAlert CD
USB Cable EPO (RJ11) Cable RS-232 Cable Owner’s Manual
*Note: 3kVA (3U) models will include a different 4-post rail kit than the one shown.
Additional Accessories (All Models; Optional)
SNMPWEBCARD: Internal network interface card for SNMP/Web control and monitoring
ENVIROSENSE: Temperature/humidity sensor for use with SNMPWEBCARD
SRSWITCH: Rack door sensor for use with ENVIROSENSE and SNMPWEBCARD
RELAYIOCARD: Programmable relay I/O card for remote UPS monitoring
2-9USTAND: Supports rack-mount UPS and battery packs in upright tower configuration (not for SU3000RTXLCD3U)
Model Specific Accessories (Optional)*
UPS Model SU750RTXLCD2U SU1000RTXLCD2U SU1500RTXLCD2U
SU2000RTXLCD2U,
SU2200RTXLCD2U SU3000RTXLCD3U
External Battery Packs
(LIMIT 1)** BP24V15RT2U BP24V15RT2U BP48V24-2U BP48V24-2U BP72V15-2U
External Battery Packs
(NO LIMIT)** BP24V70RT3U BP24V70RT3U BP48V60RT3U BP48V60RT3U BP72V28RT3U
Hot-swap PDU System PDUB15 PDUB15 PDUB15 PDUB20 PDUB30
2 Post Rack-Mount Kit 2POSTRMKITWM 2POSTRMKITWM 2POSTRMKITWM 2POSTRMKITWM 2POSTRMKITHD
5 Year Extended
Warranty WEXT5-500-1500 WEXT5-500-1500 WEXT5-500-1500 WEXT5-2200-3000 WEXT5-2200-3000
*Visit the specification page for your UPS system at tripplite.com for detailed extended runtime data and additional accessory options.
** Note: External battery pack options require configuration using front panel LCD interface or via Tripp Lite’s EXTERNAL BATTERY CONFIGURATION software. See page 23 for
more information if you are connecting external batteries to this UPS.
3
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of all
Tripp Lite UPS Systems. Failure to heed these warnings may affect your warranty.
UPS Location Warnings
Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight.
For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).
Leave adequate space around all sides of the UPS for proper ventilation.
Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the
unit’s internal cooling, eventually causing product damage not covered under warranty.
UPS Connection Warnings
Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS.
Do not modify the UPS's plug, and do not use an adapter that would eliminate the UPS’s ground connection.
Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided if anything other than Tripp Lite surge
suppressors are used to connect your UPS to an outlet.
If the UPS receives power from a motor-powered AC generator, the generator must
provide clean, filtered, computer-grade output.
The mains socket outlet that supplies the UPS should be near the UPS and be easily accessible.
To remove AC voltage from the UPS, pull the plug from the socket outlet.
Equipment Connection Warnings
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of
the life support equipment or to significantly affect its safety or effectiveness is not recommended.
Do not connect surge suppressors or extension cords to the output of your UPS. This might damage the UPS and may affect the surge
suppressor and UPS warranties.
Connect the UPS to an outlet that is adequately protected against excess currents, short circuits and earth faults, as part of the
building installation. The outlet protection for the UPS should be in series with the mains input.
Battery Warnings
Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the
batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the
UPS before performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery
replacement should be performed only by authorized service personnel using the same number and type of batteries (Sealed Lead-Acid). The
batteries are recyclable. Refer to your local codes for disposal requirements or visit tripplite.com/UPSbatteryrecycling for recycling information.
Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at tripplite.com/support/
battery/index.cfm to locate the specific replacement battery for your UPS.
Note: External battery pack options require configuration using front panel LCD interface or via Tripp Lite’s EXTERNAL BATTERY
CONFIGURATION software. See page 23 for more information if you are connecting external batteries to this UPS.


Specyfikacje produktu

Marka: Pioneer
Kategoria: nieskategoryzowany
Model: DEH-S1150UB
Kolor produktu: Czarny
Wbudowany wyświetlacz: Tak
Typ wyświetlacza: LCD
Bluetooth: Nie
Ilość portów USB: 1
Port USB: Tak
Obsługiwane formaty audio: AAC, FLAC, MP3, WAV, WMA
Kanały wyjścia audio: - kan.
Zakresy tunera: AM, FM
Ilość stacji: 24
Obsługiwane operacyjne systemy komórkowe: Android
Regulacja głośności: obrotowy
Wejście AUX: Tak
Ustawienia korektora: Tak
Obsługa typów dysków: CD, CD-R, CD-RW
Podświetlenie wyświetlacza: Tak
Dołączony tuner RDS: Tak
RDS: PTY
Ilość linii teksu: 1 linii
Panoramiczny: Tak
Odtwarzacz mp3: Tak
Odtwarzacz CD: Tak
Bezpośrednie odtwarzanie z USB: Tak
Moc rzeczywista: 200 W
Odtwarzacz CD-R: Tak
Odtwarzacz CD-RW: Tak
Liczba wyrównywaczy pasm: 5
Maksymalna moc na kanał: 50 W
Wyjście pre-out: Tak
Automatyczne dostrajanie cyfrowe: Tak
Filtr górnoprzepustowy: Tak
Filtr dolnoprzepustowy: Tak
Rozmiar DIN: 1 DIN
Usuwalny panel przedni: Tak
Języki menu ekranowego: Angielski
Regulacja głośności dzwonka: Tak

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Pioneer DEH-S1150UB, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Pioneer

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024