1.InstalltheT155withthetwofurnishedmountingscrewstoa
standard2”x4”electricalbox,4-11/16”x2-1/8”squaredevicebox
witha2”x4”adapterringortoa4”x4”boxwithaccessoryadapter
plate.
2.Forwallinstallations,mountthethermostatonaninsidewall
approximately5feetabovetheoor.Thelocationshouldprovide
circulationataverageroomtemperature.Avoiddirectsunlightor
sourcesofhotorcoldairintheroomorwall.
3.Removetheknobandthenthecover.Mountthermostatbase
assemblytotheoutletboxusingthescrewsprovided,tightenthe
screwsevenlybutdonotovertighten.Makewiringconnectionsas
noted.
4.Tousearemotesensor,removejumperJP-1todisablelocal
sensing.FailuretoremoveJP-1whenusingaremotesensorwill
causeimproperoperationofthethermostat.Someunitsdonothave
remotesensingcapability.SeeApplicationNotes.
5.Reinstallthecoverassembly.Installcoverlockingscrewprovided.
Reinstalltheknob.
© Copyright 2010 PECO, Inc. All Rights Reserved P/N 68798 3220-1449 Rev2 Page 1
Installation Instructions
TA155/TB155
Knob Removal and Replacement
InstallatIon
•READTHESEINSTRUCTIONSCAREFULLYBEFOREATTEMPTINGTO
INSTALL,OPERATEORSERVICETHISTHERMOSTAT.
•Failuretoobservesafetyinformationandcomplywithinstructionscould
resultinPERSONALINJURY,DEATHAND/ORPROPERTYDAMAGE.
•Toavoidelectricalshockordamagetoequipment,disconnectpowerbefore
installingorservicing.
•Toavoidelectricshockordamagetoequipment,useonlywiringwithinsula-
tionratedforfullthermostatoperatingvoltage.
•Toavoidpotentialfireand/orexplosiondonotuseinpotentiallyflammableor
explosiveatmospheres.
•Retaintheseinstructionsforfuturereference.Thisproduct,wheninstalled,
willbepartofanengineeredsystemwhosespecificationsandperformance
characteristicsarenotdesignedorcontrolledbyPECO,Inc.Youmust
reviewyourapplicationandnationalandlocalcodestoassurethatyour
installationwillbefunctionalandsafe.
TemperatureRange:50°F-90°F(10°C-32°C)
TA155:AHEAT-OFF-COOLsystemswitchmanuallyselectsheating
orcoolingmode.IntheHEATposition,onlytheheatoutputcycles
withdemand.IntheCOOLposition,onlythecooloutputcycleswith
demand.IntheOFFposition,heatingandcoolingoutputsareoff.Units
withatwopositionsystemswitchorwithoutasystemswitchmustuse
aloadtransferswitchwhenbothheatingandcoolingoutputsareused.
Thispreventscontrolfailureandequipmentdamagecausedbydirect
cyclingbetweenloads.
TB155:AnON-OFFsystemswitchenablesauto-changeoverofheating
andcoolingmodes.IntheONpositionthethermostatactivatesheating
orcoolingoutputsdependantupontherelationshipbetweensetpoint
andambienttemperature.Heatontocoolondeadbandis4°F.In
theOFFposition,heatingandcoolingoutputsareoff.Unitswithout
asystemswitchcyclebetweenheatingandcoolingwitha4°Fdead
band.
FAN:Someunitshaveaswitchformanualselectionoffanspeed.On
theseunitsfanoperationiseitherinternallywiredforfancontinuous
operationorisdependantuponconnectiontothefansupplyinput.
Wheninternallywiredforfancontinuousoperation,thefanwillbe
offwhenthesystemswitchisoff.Whendependantuponexternal
connectionsthefanmaynotbeoffwiththesystemswitchintheoff
position.Thefansupplyinputisswitchedtofanspeedoutputs(HI-
MED-LO).
SWITCHEDPOWER:L1powerisswitchedtothisoutputanytimethe
systemswitchisoutoftheOFFposition.
tHeRmostat opeRatIon
Whenremovingandre-installingtheT-155
knob,caremustbetaken.
•Alignarrowto70°Fontheknob(22C)or
midrangewhenremovingtheknob.
•Reinstallknobbyaligningarrowto70°F
(22C)ormidrange.
•Donotforceit.Whenproperlyaligned,the
knobwillslipintoposition.
Align arrow to 70°F
on the knob (22C)
•UseCopperwire
only,insulateorwire
nutallunusedleads.
•Anywiring,including
theremoteprobe,
maycarrythefull
operatingvoltageof
thethermostat.
caUtIon
!
caUtIon
!
WaRnInG
!
© Copyright 2010 PECO, Inc. All Rights Reserved P/N 68798 3220-1449 Rev2 Page 2
WhitewithOrangeStripe   FanHigh
WhitewithRedStripe   FanMedium
WhitewithBrownStripe   FanLow
Red     Heat
Blue     Cool
Black     L1
Yellow     L2orNeutral
Orange     SwitchedPower
Violet     FanSupply
Brown     RemoteProbe1
Brown     RemoteProbe2
     *Ifapplicable


1.Tousearemotesensor,removejumperJP-1todisablelocalsensing.



2.Remoteprobewiringshouldbelocatedawayfromanyelectrical
motorsorpowerwiring
3.Someunitsareinternallywiredforpermanentfancontinuous
operation.
4.OnunitswithaFanSupplyinputtheoperationofthefanis
determinedbywiringconnection.Forfancontinuous,jumpertheFan
Supplyinput(TB2-5)totheSwitchedPoweroutput(TB3-3).
5.Forfancyclingoperationwithacallforheatorcool,afanrelaymust
beused.
6.Observeelectricalratings.Thermostaticoutputsarepilotdutyonly.


Voltage
Rating
Inductive
FLA LRA
Resistive
Amps
Pilot
Duty
Thermostatic
Switching
24 VAC
120 VAC
240 VAC
277 VAC
N.A. N.A. N.A. 24 VA 10 VA
5.8 34.8 6.0 125 VA 20 VA
20 VA
20 VA
125 VA
125 VA
2.9 17.4 5.0
2.4 14.4 4.2
FAN AND SYSTEM SWITCHES



Specyfikacje produktu

Marka: PECO
Kategoria: termostat
Model: TB155-046

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z PECO TB155-046, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje termostat PECO

PECO

PECO TH109-009 Instrukcja

16 Września 2024
PECO

PECO T4522-001 Instrukcja

15 Września 2024
PECO

PECO SA200-001 Instrukcja

15 Września 2024
PECO

PECO TB155-046 Instrukcja

12 Września 2024
PECO

PECO TRF 115-007 Instrukcja

11 Września 2024
PECO

PECO SB200-001 Instrukcja

10 Września 2024
PECO

PECO T8532-001 Instrukcja

10 Września 2024
PECO

PECO TF115P-002 Instrukcja

10 Września 2024
PECO

PECO TF115-023 Instrukcja

8 Września 2024
PECO

PECO T12532-001 Instrukcja

7 Września 2024

Instrukcje termostat

Najnowsze instrukcje dla termostat