Strona 1/11
Manual
Electronic Balance PCE-CS 10000N
Version 1.0
Date o creation: 23.09.2015f
Date o last change: 08.0f 9.2016
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
Manual
2
Contents
1 Introduction ............................................................................................................. 3
2 Safety notes ............................................................................................................. 3
3 Specification ............................................................................................................ 5
3.1 Technical specications .............................................................................................................. 5
3.2 Delivery contents ........................................................................................................................ 5
4 System description ................................................................................................. 6
4.1 Dimensions ................................................................................................................................. 6
4.2 Display ........................................................................................................................................ 6
4.3 Remote control ........................................................................................................................... 7
4.4 Battery ........................................................................................................................................ 7
5 Operation ................................................................................................................. 8
5.1 Turn the scale on/o ................................................................................................................... 8
5.2 Zero function ............................................................................................................................... 8
5.3 Tare function ............................................................................................................................... 8
5.4 Hold function ............................................................................................................................... 8
5.5 Accumulation function ................................................................................................................ 9
5.6 Battery voltage ............................................................................................................................ 9
5.7 Brightness ................................................................................................................................... 9
5.8 Measuring unit ............................................................................................................................ 9
6 Troubleshooting .................................................................................................... 10
7 Contact ................................................................................................................... 11
7.1 PCE Instruments UK ................................................................................................................ 11
7.2 PCE Americas .......................................................................................................................... 11
Manual
3
1 Introduction
Thank you for purchasing a crane scale from PCE Instruments.
The crane scale PCE-CS 10000N can weigh up to 10 tons. To do so, the scale comes with a solid
shackle on top and a rotatable safety hook on the bottom side. The 5-digit LED display has a character
height of 30 mm, so that it is easily readable, even from a distance. The crane scale PCE-CS 10000N can
be operated from a distance up to 15 m as well by using the infrared remote control. The internal battery
of the crane scale allows up to 50 hours of operation.
2 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device
may only be used by qualied personnel and repaired by PCE Instruments personnel. There is no
warranty of damages or injuries caused by non-observance of the manual.
If the equipment is not used for a long period of time, please recharge the battery every 3
months, as well as right before the next use. Otherwise it can affect the battery life.
In order to prevent potential hazardous situations when using this measuring equipment, it is vital
to adhere to the safety precautions provided by the manufacturer.
Do not expose the equipment to extreme temperatures, direct sunlight, extreme humidity or
moisture.
Never use the measuring equipment with wet hands.
It is not permitted to carry out any technical changes on the equipment.
The equipment should only be cleaned with a damp cloth. Do not use abrasive cleaners or
detergents which contain solvents.
The equipment must only be used with accessories oered by PCE Germany or with
replacements of equal value.
The environmental conditions, for example the temperature ranges in which the measuring
equipment can be used, as stipulated in the operating instructions specications, must always be
adhered to. Otherwise the operation of the equipment is prohibited.
The measuring equipment is not to be used in an environment where there is a danger of
explosion.
Please mind the maximum capacity of the scale at any point. Do not exceed it.
In order to prevent potential hazardous situations when using heavy-lifting equipment, it is vital
the manufacturer and the operator adhere to certain requirements. When using the measuring
equipment, no risk mus t be posed to the operator.
The operator or the person responsible for operating the measuring equipment must adhere to
the national regulations for example health and safety at work regulations or any other
governmental safety standards.
There are also other safety precautions to be taken into consideration when operating the
equipment, for example precautions provided by the crane, lifting device or shackle manufacturer
etc.
The assembly, the commissioning and the servicing of the measuring equipment must only be
carried out by properly trained personnel who have been provided with the appropriate protective
equipment.
The measuring equipment must not be altered and is only allowed to be used for the intended
purpose.
The measuring equipment as well as any other equipment (for example the crane or any other
heavy-lifting equipment) must be regularly serviced and maintained and where necessary have
the service history correctly logged or certied. Each time before using the equipment a visual
check must be carried out. In the case of any discrepancies for example cracks, breaks or
deformities, the equipment must be immediately disabled and declared unt for use. This must
also be reported where necessary to the person in your company who is responsible for health
and safety.
Repairs must only be carried out by trained service personnel and only approved replacement
parts must be used when carrying out a repair. All repairs, servicing and replacement parts must
be documented by the service department
The operating instructions as well as the safety instructions must always be visible whilst using
the measuring equipment.
The measuring equipment is not explosion-proof and must not be used in an environment where
there is a danger of explosion. The environmental conditions, for example the temperature
Specyfikacje produktu
Marka: | PCE Instruments |
Kategoria: | Libra |
Model: | PCE-CS 10000N |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z PCE Instruments PCE-CS 10000N, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Libra PCE Instruments
14 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
Instrukcje Libra
- Libra Electrolux
- Libra AEG
- Libra Motorola
- Libra Beurer
- Libra Sanitas
- Libra Caso
- Libra Gorenje
- Libra LERAN
- Libra Tefal
- Libra Voltcraft
- Libra Livoo
- Libra SilverCrest
- Libra Kärcher
- Libra Severin
- Libra Withings
- Libra Nedis
- Libra Black & Decker
- Libra OK
- Libra Polar
- Libra Adler
- Libra BaByliss
- Libra Marquant
- Libra Tesla
- Libra Westinghouse
- Libra Hendi
- Libra Quigg
- Libra Niceboy
- Libra Domo
- Libra Conair
- Libra Ardes
- Libra Taurus
- Libra Orbegozo
- Libra Garmin
- Libra Blaupunkt
- Libra Grundig
- Libra Prixton
- Libra Hyundai
- Libra Silverline
- Libra Rowenta
- Libra Mesko
- Libra Concept
- Libra ECG
- Libra Mercury
- Libra Testo
- Libra SBS
- Libra TFA
- Libra Trisa
- Libra Zelmer
- Libra Medisana
- Libra Cuisinart
- Libra Wilfa
- Libra Fitbit
- Libra Bomann
- Libra Emerio
- Libra Create
- Libra Arzum
- Libra Tanita
- Libra Melissa
- Libra Beper
- Libra TrueLife
- Libra Eufy
- Libra MPM
- Libra Emos
- Libra BaseTech
- Libra Perel
- Libra Fagor
- Libra Redmond
- Libra Omron
- Libra Izzy
- Libra Velleman
- Libra ProfiCook
- Libra Manta
- Libra Pyle
- Libra Cecotec
- Libra Eta
- Libra Camry
- Libra Lenoxx
- Libra Scarlett
- Libra Microlife
- Libra Nevir
- Libra TriStar
- Libra Bartscher
- Libra Aurora
- Libra Continental Edison
- Libra Maginon
- Libra DCG
- Libra Genie
- Libra G3 Ferrari
- Libra Clatronic
- Libra Tronic
- Libra Telefunken
- Libra Inventum
- Libra Innoliving
- Libra Solac
- Libra Hama
- Libra Taylor
- Libra Duronic
- Libra Medel
- Libra Terraillon
- Libra VOX
- Libra Esperanza
- Libra Solis
- Libra Media-Tech
- Libra Gemini
- Libra Whynter
- Libra Lanaform
- Libra Topcom
- Libra Sencor
- Libra Kalorik
- Libra Steinberg
- Libra ADE
- Libra Etekcity
- Libra Becken
- Libra Bizerba
- Libra ProfiCare
- Libra Kern
- Libra Comelec
- Libra Vitek
- Libra Maestro
- Libra Ecomed
- Libra Salter
- Libra OBH Nordica
- Libra AENO
- Libra Oromed
- Libra Optimum
- Libra Alpina
- Libra Archos
- Libra ACME
- Libra Alessi
- Libra Techwood
- Libra Korona
- Libra Saturn
- Libra Sinbo
- Libra Jata
- Libra Mellerware
- Libra Heinner
- Libra Termozeta
- Libra Eldom
- Libra Cresta
- Libra Steren
- Libra Soehnle
- Libra King
- Libra Maxwell
- Libra Escali
- Libra Technoline
- Libra Exacta
- Libra Ufesa
- Libra Maul
- Libra Laica
- Libra Brabantia
- Libra Kayoba
- Libra Imetec
- Libra Sammic
- Libra Lümme
- Libra Primo
- Libra Luvion
- Libra AWS
- Libra Hema
- Libra Konig
- Libra Flow Fitness
- Libra Active Era
- Libra Mx Onda
- Libra Essentiel B
- Libra IHealth
- Libra Team
- Libra Gallet
- Libra Xavax
- Libra Balance
- Libra Fakir
- Libra Nesco
- Libra Coline
- Libra Mitsukota
- Libra Mybeo
- Libra Mia
- Libra Mettler-Toledo
- Libra Orava
- Libra Wiso
- Libra Levita
- Libra Sportstech
- Libra Silvergear
- Libra TFA Dostmann
- Libra Sanotec
- Libra CDN
- Libra American Weigh Scales
- Libra Emga
- Libra PowerTec Kitchen
- Libra Ideen Welt
- Libra Ultron
- Libra MyWeigh
- Libra Sana
- Libra Tor Rey
- Libra Louis Tellier
- Libra Cardinal Detecto
- Libra LAFE
- Libra Brecknell
- Libra KoreHealth
- Libra Girmi
- Libra Optima Scale
- Libra Seca
- Libra Little Balance
- Libra Gima
- Libra DPM
- Libra Inotec
- Libra Maman
- Libra Avery Berkel
- Libra Thinner
- Libra Picooc
- Libra A&D
- Libra Robi
- Libra Mebby
- Libra Yamazen
- Libra A&D Medical
Najnowsze instrukcje dla Libra
13 Stycznia 2025
13 Stycznia 2025
13 Stycznia 2025
12 Stycznia 2025
12 Stycznia 2025
11 Stycznia 2025
11 Stycznia 2025
11 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025