Instrukcja obsługi Panasonic CU-E21HKEA


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Panasonic CU-E21HKEA (56 stron) w kategorii Klimatyzatory. Ta instrukcja była pomocna dla 9 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/56
Operating Instructions
Air Conditioner
Indoor Unit Outdoor Unit
CS-E18HKEA CU-E18HKEA
CS-E21HKEA CU-E21HKEA
F565939
ENGLISH
ENGLISH
ENGLISH
ENGLISH ENGLISH ENGLISH 2 ~ 7
2 ~ 7
2 ~ 7
2 ~ 72 ~ 72 ~ 7
Before operating the unit, read these
Before operating the unit, read these
Before operating the unit, read these
Before operating the unit, read these Before operating the unit, read these Before operating the unit, read these
operating instructions thoroughly and
operating instructions thoroughly and
operating instructions thoroughly and
operating instructions thoroughly and operating instructions thoroughly and operating instructions thoroughly and
keep them for future reference.
keep them for future reference.
keep them for future reference.
keep them for future reference.keep them for future reference.keep them for future reference.
FRANÇAIS
8 ~ 13
8 ~ 13
8 ~ 13
8 ~ 138 ~ 138 ~ 13
Avant d’utiliser l’appareil, lisez ce mode
d’emploi dans son intégralité et conservez-le
pour toute référence ultérieure.
ESPAÑOL
14 ~ 19
14 ~ 19
14 ~ 19
14 ~ 1914 ~ 1914 ~ 19
Antes de utilizar la unidad, sírvase leer
atentamente estas instrucciones de
funcionamiento y conservarlas como
futuro elemento de consulta.
DEUTSCH 20 ~ 25
20 ~ 25
20 ~ 25
20 ~ 25 20 ~ 25 20 ~ 25
Bevor Sie das Get in Betrieb nehmen,
lesen Sie bitte diese Bedienungsanleitung
aufmerksam durch und bewahren Sie sie
r die künftige Verwendung auf.
ITALIANO 26 ~ 31
26 ~ 31
26 ~ 31
26 ~ 3126 ~ 3126 ~ 31
Prima di utilizzare l’unità si prega di leggere
attentamente le istruzioni e di conservare
questo opuscolo per potervi fare riferimento
in futuro.
NEDERLANDS
32 ~ 37
32 ~ 37
32 ~ 37
32 ~ 3732 ~ 3732 ~ 37
Lees voor u het apparaat gebruikt deze
gebruiksinstructies grondig en bewaar ze
voor toekomstig gebruik.
PORTUGUÊS 38 ~ 43
Antes de ligar a unidade, leia
cuidadosamente este manual de
utilização e guarde-o para futura
referência.
E 44 ~ 49ΛΛΗΝΙΚΆ
Προτού θέσετε τη μονάδα σε λειτουργία ,
διαβάστε προσεκτικά αυτές τις οδηγίες
χρήσης και φυλάξτε τις για μελλοντική
αναφορά.
БЪЛГАРСКИ 50 ~ 55
Преди да задействате климатика ,
прочетете внимателно инструкциите
за употреба и ги запазете за бъдещи
справки.
QU
QU
QU
QUQUIC
IC
IC
ICICK
K
K
K K GU
GU
GU
GUGUID
ID
ID
IDIDE
E
E
E E /
/
/
/ / GU
GU
GU
GUGUID
ID
ID
IDIDE
E
E
E E RA
RA
RA
RARAPI
PI
PI
PIPIDE
DE
DE
DEDEQUICK GUIDE / GUIDE RAPIDE
GU
GU
GU
GUGUÍA R
ÍA R
ÍA R
ÍA RÍA RÁP
ÁP
ÁP
ÁPÁPID
ID
ID
IDIDA /
A /
A /
A /A / K
K
K
K KUR
UR
UR
URURZA
ZA
ZA
ZAZANL
NL
NL
NLNLEI
EI
EI
EIEITU
TU
TU
TUTUNG
NG
NG
NGNGGUÍA RÁPIDA / KURZANLEITUNG
GU
GU
GU
GUGUID
ID
ID
IDIDA RA
A RA
A RA
A RAA RAPI
PI
PI
PIPIDA
DA
DA
DA DA /
/
/
/ / SN
SN
SN
SNSNEL
EL
EL
ELELLE
LE
LE
LELE G
G
G
G GID
ID
ID
IDIDS
S
S
SSGUIDA RAPIDA / SNELLE GIDS
GU
GU
GU
GUGU A R
A R
A R
A RA RÁP
ÁP
ÁP
ÁPÁPID
ID
ID
IDIDO
O
O
O O /
/
/
/ / Y
Y
Y
YYNT
NT
NT
NTNTOM
OM
OM
OMOMO
O
O
OO O
O
O
O O H
H
H
HHO
O
O
OO
Ι
Ι
Ι
ΙΙΣ
Σ
Σ
ΣΣΣ
Σ
Σ
ΣΣ
Г
Г
Г
ГГΣ
Σ
Σ
ΣΣGU A RÁPIDO / YNTOMO OΙ Σ Σ ∆ Г ΣH O
БЪ
БЪ
БЪ
БЪБЪРЗ
РЗ
РЗ
РЗРЗ С
С
С
ССПР
ПР
ПР
ПРПРАВ
АВ
АВ
АВАВОЧ
ОЧ
ОЧ
ОЧОЧНИ
НИ
НИ
НИНИК
К
К
КК
БЪРЗ СПРАВОЧНИК
© 2007 Panasonic HA Air-Conditioning (M) Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
SUPER
ALLERU-BUSTER
2
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
Remote Control
• Do not use rechargeable
(Ni-Cd) batteries.
• Do not allow infants and
small children to play
with the remote control
to prevent them from
accidentally swallowing the
batteries.
• Remove the batteries if the
unit is not going to be used
for a long period of time.
• New batteries of the same
type must be inserted
following the polarity stated
to prevent malfunction of
the remote control. Air inlet
Air inlet
Air inlet
Air inletAir inletAir inlet
Air
Air
Air
Air Air Air
outlet
outlet
outlet
outletoutletoutlet
Air outlet
Air inlet
Air inlet
Power Supply
• Do not share the same power outlet with
other equipment.
• Do not modify power cords.
• Do not use extension cords.
• Do not operate with wet hands.
• Do not operate or stop the unit by
inserting or pulling out the power plug.
• Insert the power plug properly.
• Use the speci ed supply cord.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly quali ed persons in
order to avoid a hazard.
• Dust on the electric power plug should be
periodically wiped with a dry cloth.
• This equipment must be earthed and
strongly recommended to be installed
with Earth Leakage Circuit Breaker
(ELCB) or Residual Current Device
(RCD). Otherwise, it may cause electrical
shock or re in case of malfunction.
• In case of emergency or abnormal
conditions (burnt smell, etc), turn off the
power supply and unplug, and consult
your nearest dealer.
DEFINITION
The instructions to be followed are classi ed by the following symbols:
This symbol denotes an action
that is PROHIBITED.
These symbols denote actions
that are COMPULSORY.
To prevent personal injury, injury to others, or property damage, please observe the following.
Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classi ed as below:
Warning
This sign warns of death or serious injury.
Caution
This sign warns of
injury or damage
to property.
Indoor Unit
• Do not install, remove and
reinstall the unit by yourself;
improper installation will
cause leakage, electric
shock or re. Please consult
an authorized dealer or
specialist for the installation
work.
• Do not insert your ngers or
other objects into the unit.
• Do not attempt to repair the
unit by yourself.
Outdoor Unit
• Do not insert your ngers or other objects
into the unit.
Outdoor Unit
• Do not sit, step or place anything
on the unit.
• Do not touch the sharp aluminium
n.
• Ensure that the drainage pipe is
connected properly. Otherwise,
leakage may occur.
• After long periods of use, make
sure the installation rack is not
damaged.
Power Supply
• Do not pull the cord to disconnect
the plug.
• Switch off the power supply
and unplug before cleaning or
servicing.
• Turn off the power supply and
unplug if the unit is not used for a
long period of time.
• This air conditioner is equipped
with a built-in surge protective
device. However, in order
to further protect your air
conditioner from being damaged
by abnormally strong lightning
activity, you may want to
disconnect it from the power
supply. Do not touch the air
conditioner during lightning, it
may cause electric shock.
Indoor Unit
• Do not install the unit in a
potentially explosive atmosphere.
• Do not wash the unit with water,
benzene, thinner or scouring
powder.
• Do not use for other purposes
such as preservation of food.
• Do not use any combustible
equipment in front of the air ow
outlet.
• Do not expose directly to cold air
for a long period.
• Ensure that the drainage pipe is
connected properly. Otherwise,
leakage may occur.
• Aerate the room regularly.
3
ENGLISH
REGULATORY INFORMATION REGULATORY INFORMATION
Thank you for purchasing
Air Conditioner
T
T
T
TTABLE OF CONTENTS
ABLE OF CONTENTS
ABLE OF CONTENTS
ABLE OF CONTENTSABLE OF CONTENTSTABLE OF CONTENTS
SAFETY PRECAUTIONS
2
REGULATORY INFORMATION
3
PRODUCT OVERVIEW &
OPERATIONS
4~5
CARE & CLEANING
6
TROUBLESHOOTING
7
QUICK GUIDE
BACK COVER
Replacement or installation of power plugs shall be performed by authorized/
quali ed personnel only. The wires in this mains lead are coloured in accordance
with the following code:
Terminals
Red
wires
live
neutral
earth
colours (GB Standard)
blue
green-yellow
brown
Black
Green/Yellow
Wiring colour may vary depending on a country wiring code’s standard.
OPERA
OPERA
OPERA
OPERAOPERATION CONDITION
TION CONDITION
TION CONDITION
TION CONDITIONTION CONDITIONOPERATION CONDITION
Use this air conditioner under the following temperature range
Temperature (°C) Indoor Outdoor
*DBT *WBT *DBT *WBT
COOLING Maximum 32 23 43 26
Minimum 16 11 -15 -
HEATING Maximum 30 - 24 18
Minimum 16 - -15 -
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
NOTICE: This unit is still able to operate as a cooler with outdoor temperature as
low as -15°C in a non-living room, such as a computer room, with a room
temperature of 16°C or above, and room humidity up to 80%. When the
outdoor temperature drops to -15°C, compressor will be cut off and resume
operation again once the temperature rises to more than -15°C.
When the outdoor temperature is out of the above temperature range, the
heating capacity will drop signi cantly and outdoor unit might stop for
protection control.
NOTE :
NOTE :
NOTE :
NOTE :NOTE :NOTE :
The illustrations in this manual are
for explanation purposes only and
may differ from the actual unit. It is
subjected to change without notice
for future improvement.
ENVIRONMENTAL REQUIREMENTS
Battery Disposal
The batteries must be recycled or disposed of properly.
END-OF-LIFE DISPOSAL
“Instructions for end-user” for air conditioners:
This air conditioner bears the above mark, indicating that electrical equipment should not be disposed of
alongside general household waste. European Community countries (*), should have a dedicated collection
system for these products. Do not try to dismantle the system yourself as this could have harmful effects on
your health and on the environment as a result of incorrect waste handling. This dismantling and disposal
of refrigerant, oil and other parts must be done by a quali ed installer in accordance with relevant local and
national regulations. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and
recovery and should not be disposed of in the municipal waste stream. Please contact your installer, dealer or
local authority for more information. Penalties may also be applicable for incorrect disposal of waste products,
in accordance with national legislation.
*subject to the national law of each member state
Information on Disposal in other countries outside the European Union
This symbol is only valid in the European Union. If you wish to discard this product, please contact your
installer, dealer or local authority and ask for the correct method of disposal.
• Do not switch ON the unit when waxing the oor. After waxing, aerate the room properly before operating the unit.
• Do not install the unit in oily and smoky areas.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.


Specyfikacje produktu

Marka: Panasonic
Kategoria: Klimatyzatory
Model: CU-E21HKEA

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Panasonic CU-E21HKEA, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Klimatyzatory Panasonic

Instrukcje Klimatyzatory

Najnowsze instrukcje dla Klimatyzatory

Orima

Orima ORT-18-R32 Instrukcja

15 Października 2024
Frigidaire

Frigidaire FFRE1233UE Instrukcja

15 Października 2024
Danby

Danby DAC050ME1WDB Instrukcja

14 Października 2024
Danby

Danby DPA120HUB1WDB Instrukcja

14 Października 2024
Hitachi

Hitachi RAK35NH4 Instrukcja

14 Października 2024
Danby

Danby DPA120B6WDB-6 Instrukcja

14 Października 2024
Danby

Danby DAC8006DE Instrukcja

13 Października 2024
Kelvinator

Kelvinator KSV25CRG Instrukcja

13 Października 2024
TriStar

TriStar AC-5410 Instrukcja

13 Października 2024
Samsung

Samsung ACN026NDEHA Instrukcja

13 Października 2024