Instrukcja obsługi Optex VVS-1


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Optex VVS-1 (8 stron) w kategorii Czujnik Deur/ramki. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/8
5927191 2018.05
Operation manualVVS-1
ENGLISH
Manufacturer's statement
This product is a non-contact switch intended for header mount for use on an automatic sliding door. Do not use for any other applications.
Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which the product is installed.
The image taken by this product is only used for detecting the entry direction and speed of humans entering into the door. There is no personally identifiable
information. Furthermore, the image is immediately deleted.
Be sure to use this product in a state of mounting the header sensor (OA-PRESENCE TN/OA-AXIS T/OAM-DUAL series/X-ZONE series *).
* Contact our local sales representative in case of installing this product with OA-AXIS T, OAM-DUAL series and X-ZONE series.
This product detects the entry direction and speed of humans entering into the door by means of image processing. After recognizing the movement, the
sensor judges if and when the activation output should be sent to the door.
Environment in the vicinity of the door.
Do not place the equipment generates strong radio waves and noises in the vicinity of the door.
Detection method of VVS-1
• When the floor in the human recognition area suddenly changes. (e.g. due to spaying water on the floor)
• When there are moving objects (e.g. foliage plants) in the human recognition area.
• When water drops and stain stick to the lens.
The following conditions are not suitable for stable operations.
The following conditions are not suitable for detecting humans.
• When the human recognition area is extremely dark.
• When the strong reflection light directly goes into the product.
• When the difference of the floor and clothing color is vague.
Disregard of the warning symbol can cause improper operation which may cause death or serious injury.
Disregard of the caution symbol can cause improper operation which may cause injury of a person or damage the object.
WARNING
CAUTION
Do not wash, disassemble, rebuild or repair the product, otherwise it
may cause electric shock or breakdown of the equipment.
Correctly install and set up the sensor within the range of specification.
Danger of getting caught in the door
WARNING
- 1 -
EU declaration of conformity
Hereby, OPTEX declares that the radio equipment type VVS series are in compliance with RED 2014/53/EU.
The full text of the EU DoC is available at the following internet address; www.optex.net
FCC WARNING (For USA)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
- Notice -
■ When turning the power ON, always walk-
test the detection area to ensure the proper
operation.
Do not place any objects that move or emit
light in the detection area.
(e.g. plant, illumination, etc.)
Inform building owner / operator of the following items
Read this operation manual carefully before use to ensure proper operation of this product. Failure to read this operation manual may cause improper
operation and may result in serious injury or death of a person. The meanings of the symbols are as follows.
Always keep the camera lens clean. If dirty, wipe the camera lens with a damp cloth. Do not use any
cleaner / solvent.
Do not wash the product with water.
Do not disassemble, rebuild or repair yourself, otherwise an electric shock may occur.
■ When the operation indicator blinks green, contact your installer or service engineer.
Always contact your installer or service engineer when changing the settings.
Do not paint the product.
Danger of fire and electric shock
WARNING
Danger of fire and electric shock
WARNING
VVS-1
Black
2.2 to 4.2m (7'3" to 13'10") (Maximum height depends on the header sensor)
See Image recognition area
Image recognition (Vector focus method)
24VDC (Dedicated power supply Rating input : 85 to 264VAC 1 Output voltage: 24VDC)φ
< 5.5W
Activation output : Form A relay 50V 0.1A Max. (Resistance load)
Safety output : See Operation manual of the header sensor
See Adjustments, Checking
Approx. 0.5sec.
-10°C to 50°C (14°F to 122°F)
30 to 85% (No condensation)
100 to 100,000 lx
10/100Base -T (X)
Bluetooth 4.1
Internet Explorer 11, Chrome 55 or later recommended
Approx. 30sec. from turning ON the power supply
560g (20oz)
1 Cable 3m (9'11") , 1 Mounting template , 1 manual set (Operation manual, Web setting manual and App User guide) ,
1 Mounting plate , 2 Mounting plate fixing screws, 1 Header sensor fixing screw (Attached to the main body) , 1 Protection seal set
Model
Cover color
Mounting height
Image recognition area
Detection method
Power supply
Power consumption
Output
Operation indicator
Output hold time
Operating temperature
Operating humidity
Operating illuminance
LAN specification
Communication method
Browser
Warm-up
Weight
Accessories
*The specifications herein are subject to change without prior notice due to improvements.
Specifications
- 2 -
Image recognition area
Right sideLeft side
Depth
Mounting
height
[ Human recognition area ]
The setting upper limit value for human recognition area
(Left side / Right side / Depth) is up to 10m (32'10"). Please set
according to the setting environment.
For details, refer to Web setting manual.
[ eTracker area ]
For details, refer to Web setting manual.
[ Header sensor area ]
For details, refer to Operation manual for the header sensor.
[ Door position ]
For details, refer to Web setting manual.
ドア開口部Door openings
[mm (inch)]
(1) Power/output connector
(2) App's password reset switch
(3) Header sensor mounting hole
(4) Header sensor connector
(5) Removing pawl
(6) IP address reset indicator
(1) (3)
(12)
(4) (5)
(11)
(10)
(6) (7) (8) (9)(2)
360 (1'2")
75 (3")
24 (1")
36 (1.4") 43 (1.7")
125 (5")
65.7 (2.6")
Outer dimensions and part names
(7) IP address reset switch
(8) LAN port
(9) Dipswitches
(10) Screw pocket
(11) Operation indicator
(12) Camera
Made in Japan
5741220
App's password
reset switch
Wiring
Operation
indicator
Header sensor
mounting hole
(OA-PR ESENCE TN)
1. Whit e
2. Brown
7. Red (+)
8. Black (-)
Power supply : 24VDC
3. Green
4. Yellow Act ivation output : Form A relay
50V 0. 1A max.
5. Pink (+)
6. Blue (-)
Safety input
Safety output : Opto coupler
: Opto coupler
* T urn off aft er reflection is completed.
During connect ing
the App
Slow green & blue
blinking Fast green &
blue blinking *
App passw ord
reset
Warm-up Stand-by Det ection
Green Red
Cross traffic
cancel
Green
glimmering Blue
glimmering Fas t green
blinking
Sensor
failure
Power consumption : < 5.5W
VVS-1
5741220
IP Address
reset s witch
IP Address
reset indic ator
Alignment lines
Fix the he ader s ensor , aligning the lines.
Header senso r fixing method
FCC ID : 2ABXRBVMCN5103
5741220
(SW3)
Activation output
(SW1)
N.C.
N.O.
ON
OFF
Dipswitch 2, 4 to 8 is not used
12345678
Warm-up output
- 3 -
Installation
■ When passing the cable through the hole, do not tear the shield
otherwise it may cause electric shock or breakdown of the sensor.
■ Do not use exceeding the mounting height of the specification.
Do not mount on the oblique surface.
Danger of getting caught in the door
WARNING
Fasten the screws aligning the mounting plate to the mounting holes.
Affix the mounting template at the desired mounting position.
* Mounting height depends on the header sensor.
STEP 1
STEP 2
STEP 3
STEP 4
STEP 5
STEP 6
STEP 7
STEP 8
Drill two mounting holes of ø3.4mm (ø1/8"). 2.2 to 4.2m
To pass the cable through the header, drill a wiring hole of
ø12mm (ø1/2").
Remove the mounting template.
Mounting template
Enlarged view
1. White
2. Brown
3. Green
4. Yellow
5. Pink (+)
6. Blue (-)
7. Red (+)
8. Black (-)
Power supply
Safety input
Safety output
Activation
output
24VDC
Form A relay
50V 0.1A max.
Opto coupler
Opto coupler
Door controller side
Remove the housing cover.
1.
Mounting plate
2.
Wiring the cable to the door controller.
Before starting the procedure, make sure that the power is turned
OFF.
■ Do not use this product exceeding the power supply range.
■ When passing the cable through the hole, do not tear the shield.
Otherwise it may cause electric shock or breakdown of the sensor.
■ Do not extend, forcibly bend, pull off, twist, and bundle the cable.
Danger of fire and electric shock
WARNING
Raise the knob on the left side of the
housing cover while holding the main body.
Fix the header sensor to main body by a screw, and connect to the header sensor connector.
Fix with a screw.
Fix the header sensor, aligning the lines.
Screw is attached
to the main body.
* Contact our local sales representative in case
of installing this product with OA-AXIS T,
OAM-DUAL series and X-ZONE series.
Danger of fire and electric shock
WARNING


Specyfikacje produktu

Marka: Optex
Kategoria: Czujnik Deur/ramki
Model: VVS-1

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Optex VVS-1, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Czujnik Deur/ramki Optex

Optex

Optex TX/RX-TX Instrukcja

5 Października 2024
Optex

Optex OA-Flex T Instrukcja

4 Października 2024
Optex

Optex OA-Flex Lite Instrukcja

23 Września 2024
Optex

Optex OP-08C Instrukcja

17 Września 2024
Optex

Optex VVS-1 Instrukcja

21 Sierpnia 2024
Optex

Optex Mirage Instrukcja

7 Sierpnia 2024
Optex

Optex OT-3 Instrukcja

4 Lipca 2024

Instrukcje Czujnik Deur/ramki

Najnowsze instrukcje dla Czujnik Deur/ramki

EZVIZ

EZVIZ T1 Instrukcja

14 Października 2024
Schwaiger

Schwaiger HSA250 532 Instrukcja

9 Października 2024
Kidde

Kidde K10LLDCO Instrukcja

9 Października 2024
Kidde

Kidde 2030-DCR Instrukcja

9 Października 2024
ORNO

ORNO OR-SH-17600 Instrukcja

8 Października 2024
ORNO

ORNO OR-SH-17601 Instrukcja

8 Października 2024
Emos

Emos THS916A Instrukcja

7 Października 2024
Emos

Emos GS827 Instrukcja

7 Października 2024
Emos

Emos GS869 Instrukcja

7 Października 2024
Kanlux

Kanlux MARID JQ-L Instrukcja

7 Października 2024