Instrukcja obsługi Optex SL-650QDP


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Optex SL-650QDP (4 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/4
PHOTOELECTRIC DETECTOR
BASIC MODELS
SL-200QN
SL-350QN
SL-650QN
: 60m / 200ft.
: 100m/ 350ft.
: 200m/ 650ft.
STANDARD MODELS
SL-200QDP
SL-350QDP
SL-650QDP
: 60m / 200ft.
: 100m/ 350ft.
: 200m/ 650ft.
ADVANCED MODELS
SL-200QDM
SL-350QDM
SL-650QDM
: 60m / 200ft.
: 100m/ 350ft.
: 200m/ 650ft.
HARD-WIRED MODELS
STANDARD MODEL
SL-350QFR : 100m / 350ft.
BATTERY OPERATED MODELS
BASIC MODEL
SL-350QNR : 100m / 350ft.
BEAM TOWER MODELS
SL-200QDP-BT
SL-350QDP-BT
SL-650QDP-BT
: 60m/200ft
: 100m/350ft.
: 200m/650ft.
BEAM TOWER MODEL
SL-350QFR-BT : 100m/350ft.
78.5
447.2
64
84.6
77
ABC-4
OPTIONS
Anti Bird Cap
for
• SL-200QDM/350QDM/650QDM
• SL-200QDP/350QDP/650QDP
• SL-200QN/350QN/650QN
• SL-350QFR/SL-350QNR
100
10
5
78.5
84 10
41
(mm)
Back cover
for
• SL-200QDM/350QDM/650QDM
• SL-200QDP/350QDP/650QDP
• SL-200QN/350QN/650QN
• SL-350QFR/350QNR
(mm)
458.5
138
83
452
*2sets (4 units) are used for SL series.
0.6
97
28
Actual length 150
Motor Head
Controller
Dimensions (HxWxD):
180mm x 120mm x 45mm
Conduit Bracket
for
• SL-200QDM/350QDM/650QDM
• SL-200QDP/350QDP/650QDP
• SL-200QN/350QN/650QN
(mm)
Pole Side Cover
for
• SL-200QDM/350QDM/650QDM
• SL-200QDP/350QDP/650QDP
• SL-200QN/350QN/650QN
• SL-350QFR/350QNR
(mm)
Share power source and low
battery signals
between the main unit and the
wireless transmitter.
for
• SL-350QFR/350QNR
Heating Unit
for
• SL-200QDM/350QDM/650QDM
• SL-200QDP/350QDP/650QDP
• SL-200QN/350QN/650QN
(mm)
1set(2units)
Power input
Current draw
Thermo switch
24VAC/DC
420mA(max.) (Per 1 unit)
60°C (140°F)
91
65
82
Extension Cable with
Connector
for
• SL-350QFR/SL-350QNR
Up to
150mm
BC-4 PSC-4
CBR-4 HU-3 BCU-5
BAU-4 EC-4
Beam Alignment Unit
for
• SL-200QDM/350QDM/650QDM
(applicable to receiver and transmitter)
• SL-200QDP/350QDP/650QDP
• SL-200QN/350QN/650QM
• SL-350QFR/350QNR
• SL-200QDP-BT/350QDP-BT/650QDP-BT
• SL-350QFR-BT/350QNR=BT
(applicable to receiver only)
Aligns optical axis automatically.
Input voltage
Low battery input (EX+/-)
Current draw
Output voltage
Output current
Operating temperature
Operating humidity
Normal
Low battery
Approx. 3.0 - 3.6VDC
Approx. 2.0 - 2.6VDC
3.2 - 4.0 VDC
N.C. input only
Approx. 5 μA at 3.6 VDC (no load)
100 mA (max.)
-20°C - +60°C (-40°F - +140°F)
95% (max.)
Copyright (C) 2016 OPTEX CO., LTD. No. 77043 02 15747 1702‐ ‐
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
URL: http://www.optex-europe.com
OPTEX TECHNOLOGIES B.V. (The Netherlands)
URL: http://www.optex.eu
OPTEX INC. / AMERICAS HQ (U.S.)
URL: http://www.optexamerica.com
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optex.com.pl
OPTEX PINNACLE INDIA, PVT., LTD. (India)
URL: http://www.optex.net/in/en/sec
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com
OPTEX SECURITY SAS (France)
URL: http://www.optex-security.com
OPTEX (Thailand) CO., LTD. (Thailand)
URL: http://www.optex.net/th/th
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com
By employing quad beam, it dramatically reduces false alarm caused by birds and falling
leaves. Moreover, it is also important that the housing design of both long and short beams is
harmonised. 60m (200ft.) range models, SL-200QN/SL-200QDP/SL-200QDM with a wide
beam pitch is now available.
The SL-QDM and SL-QDP series offer double modulation beams that differ in pulse
patterns. This can enhance signal discrimination against potential noise interference such
as sunlight or other external light sources, resulting in a reduction of missed or false alarms.
Together with OPTEX triple layered Sunshine Protection Technology, it ensures high
reliability under the severe outdoor security environment.
QUAD BEAM & UNITED APPEARANCE
ANTI FROST DESIGN
(Hood design)
The hoods are positioned on both the
upper beam and the lower beam to
secure a high and stable beam power by
preventing frost from attaching to the
front cover.
BEAM BLOCKING PLATE
The plate can firmly be fixed on the lens
unit without fear to be blown off by wind.
The plates can be stored in the back of
the front cover.
SLIM BODY & LIGHT WEIGHT
20% reduction of the body size and 15%
reduction of the weight come together in
the SL series.
The high-grade aspherical lens create
more sharply defined and precise active
infrared beams.
QUAD BEAM WITH
ASPHERICAL LENSES
Easy-to-see vivid interior color for optical
alignment.
VIVID INTERIOR COLOR
The alignment no longer requires a
screwdriver. All you need is touch with
your fingers for precise adjustment.
ALIGNMENT DIAL
The BAU-4 beam alignment unit
automatically and accurately adjusts
the optical axis. This allows peak
performance and gives one
technician the ability to install the
200 m (650 ft.) Smart Line detector
by himself.
BEAM ALIGNMENT UNIT : BAU-4 (option)
SNIPER VIEWFINDERTM
X2 MAGNIFICATION LENS
X2 magnification lensConventional model
RECEIVERTRANSMITTER
Rubber seals is used for all conceivable
points where water or dust may
penetrate, such as wiring holes, wire
ports and the outer openings on chassis.
IP65 WATER/DUST PROTECTION
Front cover is not clouded by ultraviolet
ray during a long term. Therefore it will
maintain the transparency of IR beams.
UV-resistant
POLY CARBONATE COVER
CONVENTIONAL SL series
The alignment level indicators have 5 LEDs, each LED represents the
level of alignment, ranging from poor to excellent. The optical alignment
level can also be checked by sound.
SL-QDM:TRANSMITTER AND RECEIVER
SL-QDP: RECEIVER only
LED INDICATOR AND SOUND ASSIST
Optical alignment can be done without using a beam
blocking plate since the SL has upper/lower beam
selection button which enables to turn on and off the
upper and lower beam alternately in the installation mode.
SL-QDM/SL-QDP only:
TRANSMITTER AND RECEIVER
UPPER/LOWER
BEAM SELECTION BUTTON
Anyone can LOCK ON,
SHUT OUT ANY TROUBLESAutomatically LOCK ON.
HORIZONTAL
V
E
R
T
I
C
A
L
The new telescope lens has a high level of
visibility for optical alignment work. Even over
long distances, a perfect installation and stable
performance can be achieved in a short period.
The IR transmitter and receiver must be perfectly aligned in order to achieve the optimal operation of the
photoelectric detector. However, a great deal of patience, time and effort is required to ensure that the receiv-
er is receiving the maximum amount of infrared signal possible from the transmitter.
Optex has the solution the SL series is designed to lighten your workload while achieving perfect alignment.
Double Modulation BeamSL-QDM/QDP only)
Transmitter Receiver
Sunlight
1st Pulse
2nd Pulse
mercury-vapor lamp
Smartline seriesConventional short beam
THE world first
AUTOMATIC
BEAM ALIGNMENT
ENVIRONMENT RESISTANCE SELECTION GUIDE
A.T.P.C.-AUTOMATIC TRANSMIT POWER CONTROL (SL-QDM only)
Automatically controls, adjusts and optimizes the power of the beam and maintains optimal performance.
It decreases false and missed alarms caused by fog, frost, cross talk, and signal saturation.
Decreased beam power
because of dense fog
FOG
Boost beam power
Beam Power UP
Caused over beam power by
the reflection from wall
signal level
Time
Sun(noise)
IR Beams(signal)
Increase signal level to avoid signal saturation
signal level
Time
Sun(noise)
IR Beams(signal)
BEAM POWER CONTROL SELECTOR (SL-QDM/SL-QDP only)
To reduce beam power when using the detector
for a distance shorter than the rated distance.
To search the peak value when making optical
alignment to support perfect alignment.
For countermeasure against interference due to unstable
S/N (signal / noise) ratio when using multiple photo beams
for long distance or beam stacking applications.
The beam power control selector allows you to manually adjust beam power from
NORMAL to LOW or VERY LOW. This function is effective for the following purposes:
VERY LOW
LOW
NORMAL
LOW
NORMAL VERY LOW
For countermeasure against crosstalk due to reflection of
wall or floor by reducing beam power.
SUNSHINE PROTECTION TECHNOLOGY (SL-QDM/SL-QDP only)
The sunshine protection technology has a triple layer construction to give better performance against external light sources
(e.g.:The sun, mercury-vapour lamps, and fluorescent lights).
31 2
HARD-WIRED MODELS
ADVANCED STANDARD BASIC STANDARD BASIC
REFLECTION
INTERFERENCE
FOG
LIGHTNING
FROST
RE-TRANSMISSION
FUNCTION
LED INDICATOR
AND
SOUND ASSIST
BATTERY OPERATED MODELS
SL-200QDM
SL-350QDM
SL-650QDM
SL-200QDP
SL-350QDP
SL-650QDP
SL-200QN
SL-350QN
SL-650QN
SL-350QFR SL-350QNR
(Expected impact :False alarm)
The light disturbance
compensation circuit
differentiates original
double modulated beams
from other external light
sources.
The photodiode
devices with IR bandpass
filter to transmit
only the same wavelength
of the IR beams.
The front cover with
special filter materials
to remove visible
lights.
1 2 3
Decrease signal level (Signal saturation)
due to rising sun or sunset which enter to the receiver
at the same angle as the transmitted IR beams.
(Expected impact :Unit damage)
(Expected impact :False alarm)
(Expected impact :False alarm)
(Expected impact :Missed alarm)
(Expected impact :Missed alarm)
Patent
pending
Most appropriate
Appropriate
Transmit power control signal
POWER UP
Transmit power control signal
POWER DOWN
Beam Power DOWN
Reduce beam power to avoid
unnecessary reflection
TX TX
RX
TX RX
RX
TX
RX
LIGHT
DISTURBANCE
WIRELESS
BEAM TOWER
MOUNTING
(BATTERY OPERATED)
WIRED
SL-200QDP-BT
SL-350QDP-BT
SL-650QDP-BT
BATTERY
OPERATED
SL-350QFR-BT


Specyfikacje produktu

Marka: Optex
Kategoria: nieskategoryzowany
Model: SL-650QDP
Kolor produktu: Czarny
Wysokość produktu: 448 mm
Szerokość produktu: 79 mm
Głębokość produktu: 96 mm
Waga produktu: 2400 g
Stopień ochrony IP: IP65
Maksymalne natężenie prądu: 0.2 A
Temperatura otoczenia: -35 °C
Temperatura otoczenia (max): 60 °C
Zakres przesyłu danych: 200 - 2000 m

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Optex SL-650QDP, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Optex

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Asko

Asko DBI644MIB.S.TW/1 Instrukcja

28 Października 2024
Asko

Asko DFS233IB.S.TW/1 Instrukcja

28 Października 2024
Emko

Emko EZM-9920 Instrukcja

27 Października 2024
Emko

Emko ESM-3712-H Instrukcja

27 Października 2024
Emko

Emko ATS-10 Instrukcja

27 Października 2024
Emko

Emko EAOM-11.2 Instrukcja

27 Października 2024
Emko

Emko EPM-3790 Instrukcja

27 Października 2024
Emko

Emko EPM-7790 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux IAN 108340 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux HG06009A-BS Instrukcja

27 Października 2024