Strona 1/8
WARNING Failure to follow the instructions provided with this indication and improper handling may cause death or
serious injury.
CAUTION Failure to follow the instructions provided with this indication and improper handling may cause injury
and / or property damage.
WARNING
Do not use the product for purposes other than the detection of moving objects such as people and vehicles.
Do not use the product to activate a shutter, etc., which may cause an accident.
Do not touch the unit base or power terminals of the product with a wet hand (do not touch when the
product is wet with rain, etc.). It may cause electric shock.
Never attempt to disassemble or repair the product. It may cause fi re or damage to the devices.
Do not exceed the voltage or current rating specifi ed for any of the terminals during installation, doing so
may cause fi re or damage to the devices.
CAUTION
Do not pour water over the product with a bucket, hose, etc. The water may enter, which may cause damage
to the devices.
Clean and check the product periodically for safe use. If any problem is found, do not attempt to use the
product as it is and have the product repaired by a professional engineer or electrician.
INSTALLATION MANUAL
・Read this instruction manual carefully prior to installation.
・After reading, store this manual carefully in an easily accessible place for reference.
・
This manual uses the following warning indications for correct use of the product and harm to you or other people and damage to
your assets, which are described below. Be sure to understand the description before reading the rest of this manual.
No. 59-1282-6 0808-20
PHOTOELECTRIC DETECTOR
AX-70TN, AX-130TN, AX-200TN
AX-100TF, AX-200TF
This symbol indicates prohibition. The specifi c prohibited action is provided in and/or around the fi guer.
This symbol requires an action or gives an instruction.
1. PRECAUTIONS
2. PARTS IDENTIFICATION
3. INSTALLATION
3-1 NOTE
3-2 INSTALLATION METHOD
4. WIRE CONNECTION
5. ALIGNMENT
5-1 OPTICAL ALIGNMENT
5-2 BEAM INTERRUPTION TIME
5-3 4 SELECTABLE BEAM FREQUENCIES * TF ONLY
6. WALK TEST
7. SPECIAL FUNCTION * TF ONLY
7-1 ENVIRONMENTAL DISQUALIFICATION
7-2 ALARM MEMORY
8. OPTIONAL ACCESSORIES
8-1 HEATING UNIT : HU-3
8-2 BACK COVER : BC-3
8-3 POLE SIDE COVER : PSC-3
9. TROUBLE SHOOTING
10. SPECIFICATIONS
C O N T E N T S
For Safe Use of the Product
< STANDARD >
< 4 SELECTABLE BEAM FREQUENCIES >
• 4 selectable beam frequencies
• LED indicator for fi ne beam alignment level
• D.Q. circuit (Environmental disqualifi cation)
• Alarm memory
< AX-100/200TF ONLY >
• High-performance waterproof structure
• Horizontal alignment dial for user-friendliness
• Adjustable beam interruption period
• Tamper function
• Optional Accessories : Heating unit (HU-3), Back cover (BC-3),
Pole side cover (PSC-3)
• UL Listed
< AX-70/130/200TN, AX-100/200TF >
Features
N219
Distances between the Receiver and the Transmitter
Wiring
Hole
View Finder
Vertical Alignment
Screw
Terminals
•Transmitting
Condition LED
(Transmitter)
•Alarm Indicator LED
(Receiver)
Monitor Jack
(Receiver)
Horizontal
Alignment Dial
Waterproof Plug
Selection Dip Switch
(See "4 WIRE
CONNECTION",
"5-2 BEAM
INTERRUPTION
TIME", and "7-2
ALARM MEMORY *
TF ONLY")
3.3ft.(1m)
Alarm Memory
(Receiver)
(See "7-2 ALARM
MEMORY * TF
ONLY")
Selection Switch
(See "5-3 4
SELECTABLE BEAM
FREQUENCIES * TF
ONLY")
1) Loosen the cover lock screw to detach the cover.
2) Turn the optical unit and open the waterproof plug.
3) Loosen the unit base lock screw and slide the mounting plate
downward to detach the unit base.
1. PRECAUTIONS
2. Do not install the unit where objects
moved by the wind such as plants and
laundry, which may block the beam.
1. Mount unit only on a solid surface.
4. A different type of beam
should not reach the receiver.
3.
Prevent direct sunlight
from entering into internal
receiver.
5. Avoid aerial wiring. 6. Do not install the unit
on unsteady surfaces.
receiver
transmitter
(other model)
transmitter
3
2. PARTS IDENTIFICATION
Optical Unit
Cover
Unit Base
Mounting Plate
Pole-mounting Bracket
3. INSTALLATION
・
Pole size should be 1 1/4”-1 7/8” ( φ32-48mm).
(Standard U.S. 1 1/4” or 1 1/2”pipe)
ex) AX-70TN : 70ft.(20m)
2.3ft.-3.3ft. (0.7-1m)
180(±90) 10(±5)
Horizontally Vertically
about 2.0ft.(60cm)
about 3.3ft.
(1m)
It is not recommendable to install the units in this way
(or direction). In case you do this installation, maximum
detection range shall be half of the original detection range.
(This is to prevent the attenuation of beam by the edge of
the cover.)
1. Detach the cover and the screw 2. Fix the mounting plate
When removing the cover, do not put your fi ngers
on the hood, whitch may cause damage.
Cover Lock Screw
Hood Optical Unit
Waterproof Plug
Unit Base lock Screw
Wall Mounting Screws
Mounting Plate
Wall mounting Pole mounting (1 plate) Pole mounting (2 plate)
Mounting Plate
Lock Screws
Pole Lock Screws
7. Mount the units more
than 1m away from the
wall or fence.
Note
3-2. INSTALLATION METHOD
3-1. NOTE
1. Detection range and installation 2. Alignment angle 3. Pole mounting
Wire size
Power supply voltage
12VDC 24VDC
AWG22
(0.33mm2)1600ft. (
500m)7800ft.(2400m)
AWG20
(0.52mm2)2200ft. (
700m)11400ft.(3500m)
AWG18
(0.83mm2)3600ft.(1100m
)18000ft.(5500m)
AWG16
(1.31mm2)5500ft.(1700m
)26200ft.(8000m)
Power input
10.5 to 28VDC
+ -
Tamper output : (BE) Model only
(it opens when cover is removed)
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
“For UL Listed applications, the units shall be connected to a UL
Listed control unit or Listed Burglar Power Supply capable of
providing a minimum of 4 hours standby power.”
Note: Non-Voltage contact output
Resistive load only
TAMPER
Power input
10.5 to 28VDC
+ -
Tamper output : (BE) Model only
(it opens when cover is removed)
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
TAMPER
3. Wiring
Use wires in compliance with the following conditions:
1) Wire diameter: φ4 - 7mm
2) When using any other wires than the above, seal the wiring port
with a waterproof agent (silicon, etc.) to prevent water from coming
in through the gap.
3) Number of wires: 3 (max.)
Wiring Hole 1
3 wires can be accommodated in a unit.
Lead-in wire should be as below.
*Wiring hole 2 needs to be punched with a screw driver, etc.
* To have the wiring hole 3, wiring port needs to be cut with a cutter knife,
etc. After inserting the wire, seal the wiring port with a waterproof material
like silicon for leakage prevention.
Wiring Hole 2
Figure 1 Figure 2
Wiring guide should be as below.
Knockout needs to be opened with a nipper, etc.
Knockout
Cutting
Figure 3
5. Alignment and walk test
4. Mount the unit base
Connect the terminals with reference to “4. WIRE
CONNECTION” and slide the unit base into the mounting
plate from above, then fasten the unit base mounting
screws to fi x the unit base. Then, push in the waterproof
plug up to the broken line shown in the fi gure above.
Waterproof Plug
Unit Base
Lock Screw
Align the optical axis to the maximum
receiving level according to “5-1.
OPTICAL ALIGNMENT”. Then, check
for the operation with reference to “6.
WALK TEST”.
Put the cover and tighten the
cover lock screw.
Make sure that the cover edge
has reached the line prepared
on the side of the unit base
(See the fi gure left)
Screwdriver Line
Push in up to
this position
Side view of the waterproof plug
WARNING
Do not exceed the voltage
or current rating specifi ed
for any of the terminals
during installation,
doing so might cause fi re
or damage to the devices.
<Receiver >
Power input
10.5 to 28VDC
Alarm output (N.C.)
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
+−ALARM TAMPER
Tamper output
(It opens when cover is removed)
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
1. Terminal
<Transmitter >
Connect respective wires to the terminals shown in the following fi gure.
・
Ensure that the wiring distance from the
power supply is within the range shown in
the table on the right.
・
When using two or more units on one wire,
the maximum length is obtained by dividing
the wire length listed below by the number
of units used.
2. Wiring distance between power
supply and detector
4. WIRE CONNECTION
[AX-70/130/200TN]
+COM.N.O. TAMPER
[AX-100/200TF]
Alarm output: (N.C./N.O.) switch (In case of using N.O., contact is not reversed when power supply is off.)
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
Use the COM. terminal for both alarm
output and D.Q. circuit.
Knockout
N.C.
Power input
10.5 to 28VDC
Tamper output
(It opens when cover is removed)
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
Environmental Disqualifi cation (N.C.)
Non-Voltage contact output
Contact capacity : 28VDC and 0.2A (max.)
N.C. / N.O. selection Swich
N.C. ⇔
N.O.
3
OFF ON
<Receiver >
<Transmitter >
N.C./
Specyfikacje produktu
Marka: | Optex |
Kategoria: | detektor ruchu |
Model: | AX-70TN |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Optex AX-70TN, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje detektor ruchu Optex
17 Grudnia 2024
17 Grudnia 2024
17 Grudnia 2024
17 Grudnia 2024
17 Grudnia 2024
17 Grudnia 2024
6 Grudnia 2024
6 Grudnia 2024
6 Grudnia 2024
13 Września 2024
Instrukcje detektor ruchu
- detektor ruchu Joy-It
- detektor ruchu Philips
- detektor ruchu Gigaset
- detektor ruchu Hikvision
- detektor ruchu Theben
- detektor ruchu Crestron
- detektor ruchu Nedis
- detektor ruchu Nexa
- detektor ruchu D-Link
- detektor ruchu Blaupunkt
- detektor ruchu Honeywell
- detektor ruchu Steinel
- detektor ruchu Swann
- detektor ruchu ORNO
- detektor ruchu Chamberlain
- detektor ruchu DSC
- detektor ruchu Trust
- detektor ruchu IFM
- detektor ruchu Vimar
- detektor ruchu V-TAC
- detektor ruchu Dahua Technology
- detektor ruchu Schneider
- detektor ruchu Renkforce
- detektor ruchu Perel
- detektor ruchu Somfy
- detektor ruchu Velleman
- detektor ruchu Homematic IP
- detektor ruchu Intertechno
- detektor ruchu Devolo
- detektor ruchu EtiamPro
- detektor ruchu Grothe
- detektor ruchu Axis
- detektor ruchu Suevia
- detektor ruchu Abus
- detektor ruchu Olympia
- detektor ruchu Marmitek
- detektor ruchu Goobay
- detektor ruchu Schwaiger
- detektor ruchu Hager
- detektor ruchu Yale
- detektor ruchu InLine
- detektor ruchu Vemer
- detektor ruchu Busch-Jaeger
- detektor ruchu Fibaro
- detektor ruchu EQ-3
- detektor ruchu Powerfix
- detektor ruchu Alecto
- detektor ruchu JUNG
- detektor ruchu Eaton
- detektor ruchu Smartwares
- detektor ruchu Elgato
- detektor ruchu Cotech
- detektor ruchu Kopp
- detektor ruchu Inovonics
- detektor ruchu ACME
- detektor ruchu Lucide
- detektor ruchu Eminent
- detektor ruchu KlikaanKlikuit
- detektor ruchu Techly
- detektor ruchu Steren
- detektor ruchu ESYLUX
- detektor ruchu Arlo
- detektor ruchu Merten
- detektor ruchu Chacon
- detektor ruchu Massive
- detektor ruchu Aqua Joe
- detektor ruchu Konig
- detektor ruchu DESQ
- detektor ruchu Xavax
- detektor ruchu Orbis
- detektor ruchu Niko
- detektor ruchu Gira
- detektor ruchu Interlogix
- detektor ruchu HQ
- detektor ruchu Iget
- detektor ruchu Satel
- detektor ruchu Wentronic
- detektor ruchu EQ3
- detektor ruchu Vernier
- detektor ruchu Chuango
- detektor ruchu Berker
- detektor ruchu Extron
- detektor ruchu Maxsa
- detektor ruchu Kogan
- detektor ruchu Brinno
- detektor ruchu Legrand
- detektor ruchu Bitron
- detektor ruchu Pentatech
- detektor ruchu RAB
- detektor ruchu BEA
- detektor ruchu Tellur
- detektor ruchu Megatron
- detektor ruchu Ledvance
- detektor ruchu Gewiss
- detektor ruchu ALC
- detektor ruchu Avigilon
- detektor ruchu GEV
- detektor ruchu Pepperl+Fuchs
Najnowsze instrukcje dla detektor ruchu
9 Stycznia 2025
29 Grudnia 2024
29 Grudnia 2024
26 Grudnia 2024
26 Grudnia 2024
25 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024