Instrukcja obsługi Neutrik NE8FDP-R-B


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Neutrik NE8FDP-R-B (34 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/34
87
Data Connectors
setting standards
88
C o n t e n t P a g e
Fiber Optic:
opticalCON ADVANCED .............................................. 90
opticalCON DUO - Cable Connector Assembly ............. 92
opticalCON DUO - Chassis Connector ......................... 92
opticalCON QUAD - Cable Connector Assembly ........... 93
opticalCON QUAD - Chassis Connector ....................... 93
opticalCON MTP® - Cable Connector Assembly ............. 94
opticalCON MTP® - Chassis Connector ......................... 94
opticalCON Breakout Boxes & Coupler ......................... 95
opticalCON D-shape Z-panels ..................................... 95
opticalCON powerMONITOR ...................................... 96
opticalCON Acceccories & opticamSWITCH ................. 97
opticalCON LITE .......................................................... 98
opticalCON DUO LITE - Cable Connector Assembly ...... 100
opticalCON QUAD LITE - Cable Connector Assembly .... 100
opticalCON MTP® LITE - Cable Connector Assembly ..... 101
Network Interconnections:
etherCON - CAT6 Cable Carrier ................................ 103A
etherCON - CAT6 Receptacles .................................. 103A
etherCON - CAT6 - Technical Data ............................ 104A
etherCON - CAT6 - Ordering Information .................. 104A
etherCON - CAT5e A / B / D type Receptacle .............. 105
etherCON - Receptacles .............................................. 106
etherCON - Receptacle Shield & Lighted ..................... 107
etherCON - Feedthrough ........................................... 107
etherCON - Cable Carrier .......................................... 108
etherCON - Technical Data ........................................ 109
etherCON - Ordering Information .............................. 110
etherCON - Accessories ............................................. 111
etherCON - CAT6 Patch Cable .................................... 112
etherCON - CAT6 Receptacles .................................... 112
etherCON - CAT6 - Technical Data ............................. 113
etherCON - CAT6 - Ordering Information ................... 113
Digital Interfaces (USB / IEEE / HDMI / D-SUB):
USB Patch Cable ...................................................... 114
USB 2.0 Receptacle ................................................... 115
USB 3.0 Receptacle ................................................... 115
Technical Data USB Receptacle and Patch Cable ......... 116
Ordering Information USB Receptacle and Patch Cable ... 116
HDMI Patch Cable ..................................................... 117
HDMI Receptacle ...................................................... 117
Firewire Receptacle ................................................... 118
D-SUB Receptacle ...................................................... 118
HDMI, Firewire, D-SUB - Technical Data .................... 119
HDMI, Firewire, D-SUB - Ordering Information .......... 119
Accessories .............................................................. 120
Neutriks continuously growing range of data
connectors copes with the increasing and versatile
demand of digital connections in the professional
audio, broadcast and entertainment industry.
Networking and computerized controls have to be
equipped with reliable and rugged interconnection
systems, since conventional data connectors can not
meet the demanding requirements of live / rental or
broadcast applications.
Neutrik early understood this trend and realized
a range of ruggedized connection systems based
on standard digital interconnection products like
fiber optic and network interconnections as well as
Digital Interfaces HDMI, USB, D-SUB and Firewire to
suit the high demands of professional users in the
entertainment industry.
I n t ro d u c t i o n
D a t a C o n n e c t o r s
NEUTRIK®, crystalCON®, etherCON®, maxCON®, miniCON®,
nanoCON®, neutriCON
®, opticalCON®, powerCON®, Profi®,
rearTWIST®, silentPLUG®, speakON®, DIWA® ,XIRIUM®,
are registered trademarks of Neutrik AG.
www.neutrik.com 89
fiberopticsystems
F i b er O pti c
A few years ago, fiber optic cables were used for specific
applications only. With the transition to HD-signals and the
upcoming 4K / 8K technology the need for fiber optics has
increased significantly. Today, fiber optic cables are widely-
used for various applications in the fields of professional
broadcast, pro audio and touring/rental industries.
Digital HD video transmissions > 15m (e.g. DVI, HDMI or
KVM projection) using fiber optic media converters
Increased bandwidth, especially for professional broadcast
applications
Efficient handling due to smaller and lighter cables
Minimized cabling by embedding multiple data signals in
single cables
Future-proof installations designed to eliminate distance
limitations, noise and EMI protection on audio or video
(LED walls) applications
With the increased use of fiber optics for pro audio
and broadcast new connections had to be developed.
Conventional data-communication connectors (ST, SC, LC,
etc.) are optimized for permanent, one-time connections and
cannot cope with the harsh and demanding environment
occurring in the entertainment business.
Neutrik solved the various problems associated with mobile
fiber optic connectivity by launching the opticalCON series
in 2005.
The simple and rugged design of opticalCON provides low
fiber maintenance, high mating cycles and easy handling.
Well known professional equipment manufacturers as well
as key users in the pro broadcast and touring industry trust
in the opticalCON system for years. It’s Neutrik´s goal to turn
opticalCON into an industry standard comparable to the
widely used etherCON series.
De si g n C ri te ri a
Neutrik solved the various problems associated with mobile
fiber optic connectivity with the launch of the opticalCON
DUO fiber optic connection system in 2005.
opticalCON’s reliable and simple concept, with ruggedness
and low maintenance at its core, has gained wide acceptance
in the pro audio and broadcast industries. Well-known
professional equipment manufacturers as well as key users in
broadcast and rental/ touring trust in opticalCON for years. It
is Neutrik goal to turn opticalCON into an industry standard
comparable to the widely used etherCON series.
opticalCON DUO is most typically used for equipment
connections, including various audio, lighting, and video
applications. Typical uses include audio and DMX networks
(ring switch), video projection based on fiber optic DVI,
HDMI, or KVM signal converters, mobile LED panels, and
various broadcast applications.
Following on the success of opticalCON DUO, the newer
opticalCON QUAD series doubles the fiber count to four
per cable and is designed with point-to-point connections in
mind. opticalCON QUAD has been successfully deployed in
such applications as data routing for big and, especially, OB
outdoor broadcast applications.
The CONoptical MTP® increases the numbers of fibers in
one connector to 12 and is the ideal solution for multi-fiber
point-to-point applications as often required for broadcast
applications.
Alternatively SPLIT cables, assembled with opticalCON DUO
or QUAD, support a connector standardization and offers
advantages with regard to field assembly and repair costs.
With the brand new , a cost effective opticalCON LITE
lightweight connector based on LC based ferules. Neutrik
offers a high performance fiber connection system for
permanent and temporary installations like server rooms,
patch fields and indoor cabling.
o p t i c a l C O N


Specyfikacje produktu

Marka: Neutrik
Kategoria: Niesklasyfikowane
Model: NE8FDP-R-B
Kolor produktu: Black, Green, Silver
Wysokość produktu: 31 mm
Szerokość produktu: 26 mm
Prąd: 1.5 A
Certyfikaty: TIA/EIA 586B, IEC11801, UL 94 V-0
Zakres temperatur (eksploatacja): -30 - 80 °C
Napięcie: 50 V
Materiały: Bronze, Metal, Nickel, Zinc
Ilość gniazd: 1
Typ gniazda: RJ-45
Rezystancja izolacji: 500 MΩ

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Neutrik NE8FDP-R-B, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Neutrik

Neutrik

Neutrik NC3MX Instrukcja

22 Września 2024
Neutrik

Neutrik NPPA-TT-S Instrukcja

22 Września 2024
Neutrik

Neutrik NO12MBB3Q-A Instrukcja

21 Września 2024
Neutrik

Neutrik NE8MC6-MO Instrukcja

21 Września 2024
Neutrik

Neutrik FOCD-CF Instrukcja

21 Września 2024
Neutrik

Neutrik NPPA-TT-PT Instrukcja

21 Września 2024
Neutrik

Neutrik NC3MXX Instrukcja

21 Września 2024
Neutrik

Neutrik NO4MBB2D-A Instrukcja

21 Września 2024
Neutrik

Neutrik NO4SABB4D-A Instrukcja

20 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024