The Signature Series is designed for amateur installation. NOT Installation SHOULD be performed by an authorized technician.
Please read this manual carefully before installation and keep it for future reference.
The Signature Series is designed for amateur installation. NOT Installation SHOULD be performed by an authorized technician.
Please read this manual carefully before installation and keep it for future reference.
Installation Manual
Signature Series
MHP15*A HEAT PUMP SPLIT SYSTEM
Page 1 of 11506318-03C mrcool.com
Save these instructions for future reference
INSTALLATION INSTRUCTIONS
(R410A REFRIGERANT)
(P) 506318-03C
*P506318-03C*
Manufactured By
MRCOOL, LLC
Hickory, KY 42051
This manual must be left with the homeowner for future reference.
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in
manuals, be alert to the potential for personal injury or death.
result in hazards to you and others. Installation MUST
conform with local building codes and with the National
Electrical Code NFPA 70/ANSI C1-1993 or current
edition and Canadian Electrical Code Part 1 CSA C22.1.
WARNING
Improper installation, adjustment, alteration, service
installer or agency must use factory-authorized kits
or accessories when added to this products. Refer to
accessory kit.
CAUTION
These instructions are intended as a general guide and
do not supersede national, state or local codes in any
way.
NOTE
These instructions and warranty are to be given to the
owner or displayed near the indoor air handler unit.
NOTE TO INSTALLING DEALER
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position.
There may be more than 1 disconnect switch. Lock out
and tag switch with a suitable warning label. Electrical
shock can cause personal injury or death.
WARNING
Table of Contents
Safety Precautions ......................................................2
Installation ...................................................................2
Electrical Connections.................................................5
Start-Up Procedure......................................................6
Operation.....................................................................7
Homeowner’s Information .........................................10
MHP15*A HEAT PUMP SPLIT SYSTEM
506318-03CPage 2 of 11 mrcool.com
NOTE: Maximum liquid-line size is 3/8 in. O.D. for all
residential applications including long lines.
Outdoor Section
Zoning ordinances may govern the minimum distance the
condensing unit can be installed from the property line.
Install on a Solid, Level Mounting Pad
The outdoor section is to be installed on a solid foundation.
This foundation should extend a minimum of 2” (inches)
beyond the sides of the outdoor section. To reduce the
possibility of noise transmission, the foundation slab
should NOT be in contact with or be an integral part of the
building foundation.
Elevate Unit
Accumulation of water and ice in base pan may cause
equipment damage.
CAUTION
Elevate unit per local climate and code requirements to
provide clearance above estimated snowfall level and
ensure adequate drainage of unit. Use snow stand in areas
where prolonged freezing temperatures are encountered.
If conditions or local codes require the unit be attached to
pad or mounting frame, tie down bolts should be used and
fastened through knockouts provided in unit base pan.
Rooftop Installations
Mount on level platform or frame 6 inches above roof
surface. Place unit above a load-bearing wall and isolate
unit and tubing set from structure. Arrange supporting
members to adequately support unit and minimize
transmission of vibration to building. Ensure roof structure
and anchoring method is adequate for location. Consult
local codes governing rooftop applications.
Roof mounted units exposed to winds above 5 mph may
coil. The height should cover the face of the coil and the
length should be 6” from the access panel.
NOTE: Unit must be level to within ± 1/4 in./ft. per
Clearance Requirements
snow, or ice from roof or eaves cannot fall directly on unit.
These units are designed for use in residential and
light commercial type buildings. Heat Pumps may only
be installed with indoor combinations listed in the Air
Conditioning, Heating and Refrigeration Institute (AHRI)
Inspect the unit for any damage before installation. If
damage is found, notify the transportation company
Safety Precautions
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for brazing operations.
thoroughly and follow all warning or cautions attached to
the unit.
1. Always wear proper personal protection equipment.
2. Always disconnect electrical power before removing
panel or servicing equipment.
3. Keep hands and clothing away from moving parts.
4. Handle refrigerant with caution, refer to proper MSDS
from refrigerant supplier.
5. Use care when lifting, avoid contact with sharp edges.
Installation
NOTE: In some cases noise in the living area has been
traced to gas pulsations from improper installation of
equipment.
1. Locate unit away form windows, patios, decks, etc.
where unit operation sounds may disturb customer.
2. Ensure that vapor and liquid tube diameters are
appropriate to capacity of unit.
3. Run refrigerant tubes as directly as possible by
avoiding unnecessary turns and bends.
4. Leave some slack between structure and unit to
absorb vibration.
5. When passing refrigerant tubes through the wall, seal
opening with RTV or other silicon-based caulk.
6. Avoid direct tubing contact with water pipes, duct work,
7. Do not suspend refrigerant tubing from joists and
studs with a rigid wire or strap which comes in direct
contact with tubing.
8. Ensure that tubing insulation is pliable and completely
surrounds vapor tube.
When outdoor unit is connected to factory-approved indoor
unit, outdoor unit contains system refrigerant charge for
operation with indoor unit of the same size when connected
check refrigerant charge using charging information
located on control box cover.
Specyfikacje produktu
Marka: | MRCOOL |
Kategoria: | pompa ciepła |
Model: | MHP15042A |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z MRCOOL MHP15042A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje pompa ciepła MRCOOL
21 Września 2024
20 Września 2024
19 Września 2024
18 Września 2024
Instrukcje pompa ciepła
- pompa ciepła Samsung
- pompa ciepła Tesy
- pompa ciepła AEG
- pompa ciepła Balay
- pompa ciepła LG
- pompa ciepła Bosch
- pompa ciepła Fujitsu
- pompa ciepła Ferroli
- pompa ciepła Miele
- pompa ciepła Waterco
- pompa ciepła Midea
- pompa ciepła Hisense
- pompa ciepła Hydro-Pro
- pompa ciepła Westinghouse
- pompa ciepła Blaupunkt
- pompa ciepła Vivax
- pompa ciepła Siemens
- pompa ciepła Grundig
- pompa ciepła Fisher & Paykel
- pompa ciepła Remeha
- pompa ciepła Hotpoint
- pompa ciepła Wilfa
- pompa ciepła Daikin
- pompa ciepła Kospel
- pompa ciepła Viessmann
- pompa ciepła Danfoss
- pompa ciepła Vaillant
- pompa ciepła JANDY
- pompa ciepła Grundfos
- pompa ciepła Qlima
- pompa ciepła Mitsubishi
- pompa ciepła Dimplex
- pompa ciepła Baxi
- pompa ciepła Arçelik
- pompa ciepła Remko
- pompa ciepła Orima
- pompa ciepła Junkers
- pompa ciepła Carrier
- pompa ciepła AstralPool
- pompa ciepła De Dietrich
- pompa ciepła Nefit
- pompa ciepła Alpha Innotec
- pompa ciepła Stiebel Eltron
- pompa ciepła Elco
- pompa ciepła Nibe
- pompa ciepła Itho-Daalderop
- pompa ciepła Zodiac
- pompa ciepła Atlantic
- pompa ciepła AWB
- pompa ciepła Maxicool
- pompa ciepła Azuro
- pompa ciepła Wita
- pompa ciepła Calorex
- pompa ciepła Fairland
- pompa ciepła Techneco
- pompa ciepła Thermor
- pompa ciepła Armstrong
- pompa ciepła Flojet
- pompa ciepła Harmopool
- pompa ciepła Wilo
Najnowsze instrukcje dla pompa ciepła
14 Stycznia 2025
12 Stycznia 2025
12 Stycznia 2025
12 Stycznia 2025
12 Stycznia 2025
12 Stycznia 2025
11 Stycznia 2025
11 Stycznia 2025
9 Stycznia 2025
3 Stycznia 2025