Instrukcja obsługi Morco GB24 Series II

Morco Bojler GB24 Series II

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Morco GB24 Series II (40 stron) w kategorii Bojler. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/40
User & Installation Instructions
GB24 & GB30
Series II
pre he at
pre he at
min mi n
max
mod e
re se t
of f st at us bur ne r
max
e
Morco House, Riverview Road, Beverley, East rkshire, HU17 0LDYo
Morco Produc Ltdts
Tel: 01482 325456 Fax: 01482 212869
Website: www.morcoproduc .co.ukts
To Domestic Hot Water:
GB24/30 Minimum 8.0 kW (27,296 Btu/h)
GB24 Maximum 24.2 kW (82,570 Btu/h)
GB30 Maximum 30.3 kW (103,384 Btu/h)
To Central Heating:
GB24/30 Minimum 8.0 kW (27,296 Btu/h)
GB24/30 Maximum 24.2 kW (82,570 Btu/h)
BOILER OUTPUT
Series IIGB24
UIN 212134 A08
July 2018
2
MODEL
SYMBOL UNITS 24 30
Condensing Boiler n/a n/a yes yes
Low Temperature Boiler n/a n/a no no
B1 Boiler n/a n/a no no
Cogeneration Space Heater n/a n/a no no
Equipped with a Supplementary Heater n/a n/a no no
Combination Heater n/a n/a yes yes
Nominal Heat Output for Space Heating
Full Load P4kW 24.3 24.3
Part Load P1kW 8.0 8.0
Auxiliary Electricity Consumption
Full Load elmax kW 0.042 0.031
Part Load elmin kW 0.012 0.013
Standby PSB kW 0.005 0.005
Seasonal Space Heating Energy Efciency
Full Load ƞ4% 90.0 90.0
Part Load ƞ1% 98.7 98.7
Standby Loss Pstby kW 0.050 0.050
Ignition Pign kW 0 0
Emissions NOxmg/kWh 26 26
Annual Energy Consumption Q HE GJ 75 75
Sound Power Level, Indoors LWA dB 45 46
Domestic Hot Water
AEC kWh 16 16
AFC GJ 6 6
ERP DATA
All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded in the
Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500.
3
MORCO COMBINATION BOILER
Morco Products Ltd
ERP DATA
SYMBOL UNITS MODEL
24 30
Condensing boiler Yes
Seasonal Space heating efciency class A
Rated heat output kW 24
Seasonal space heating energy efciency ƞs% 94*
Annual energy consumption QHE GJ 76
Sound power level, indoors LWA dB 45 46
Water heating energy efciency class A
Seasonal Space Heating Energy Efciency of the Boiler *%
Temperature control (from che of temperature control) %
Class I Class II Class III Class IV Class V Class VI Class VII Class VIII
1% 2% 1.5% 2% 3% 4% 3.5% 5%
PRODUCT FICHE
 
The energy efciency of the package of products provided for in this document may not correspond to its actual energy efciency once installed in a
building, as the efciency is inuenced by further factors such as heat loss in the products in relation to the building size and its characteristics
Collector Size
(in m2)
Tank Volume
(in m3)
Collector
Efciency
(in %)
Tank rating
A* = 0.95
A = 0.91
B = 0.86
C = 0.83
D-G = 0.81
Solar Contribution (from che of solar device)
Seasonal Space Heating Energy Efciency of Package
TOTAL: A+B+C=
Seasonal Space Heating Energy Efciency Class of Package
= (‘ ’x + ‘ ) x 0.9 x ( / 100 x =III IV x %
%
G F E D C B A A+ A++ A+++
< 30% ≥ 30% ≥ 34% ≥ 36% ≥ 75% ≥ 82% ≥ 90% ≥ 98% ≥ 125% ≥ 150%
A
B
C


Specyfikacje produktu

Marka: Morco
Kategoria: Bojler
Model: GB24 Series II

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Morco GB24 Series II, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą