Installation
Instructions
30", 36" and 48"
Professional
Restaurant Style
Vent Hoods
Models:
ZV48R
ZV36R
ZV30R
2
Installation Instructions
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at
the service panel and lock service panel to prevent
power from being switched on accidentally. If the
service panel cannot be locked, fasten a tag or
prominent warning label to the panel.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE
CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT
OBSERVER LES REGLES SUIVANTES:
A. Utiliser cet appareil uniquement de la maniére
prévue par le fabricant. En cas de question, consulter
le fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et
verrouiller le panneau du disjoncteur pour éviter la
mise sous tension accidentelle. S’il n’est pas possible
de verrouiller le panneau du disconcteur, attacher
un placard ou une étiquette trés visible au panneau.
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials or vapors.
Structural framing, installation work and electrical
wiring must be done by qualified person(s). In
accordance with all applicable codes and standards
including fire-rated construction.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such as those
published by the National Fire Protection Association
(NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
Local codes vary. Installation electrical connections
and grounding must comply with applicable codes.
In the absence of local codes, the vent should be
installed in accordance with National Electrical
Code ANSI/NFPA 70-1990 or latest edition.
CAUTION: To reduce risk of fire and to
properly exhaust air, be sure to duct air outside – Do
not vent exhaust air into spaces within walls or ceilings
or into attics, crawl spaces, or garages.
PRUDENCEIl faut prendre soin
d’installer un conduit vers l’extérieur pour réduire le
risque d’incendie et pouvoir évacuer l’air correctement.
Il ne faut pas évacuer l’air correctement. Il ne faut pas
évacuer l’air dans l’espace entre les parois d’un mur,
un plafond ou un grenier, un espace sanitaire ou un
garage.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT – Save these instructions for
local inspectors use.
• IMPORTANT – Observe all governing codes
and ordinances.
Note to Installer – Be sure to leave these instructions
with the Consumer.
Note to Consumer – Keep these instructions for
future reference.
Skill Level – Installation of this vent hood requires
basic mechanical and electrical skills.
Completion time – 1 to 3 hours.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
CAUTION:
Due to the weight and size of these vent hoods and to
reduce the risk of personal injury or damage to the
product, TWO PEOPLE ARE REQUIRED FOR
PROPER INSTALLATION.
PRUDENCE
À cause du poids et de la taille de ces hottes et pour
reduire le risque de blessures et de dommages, IL FAUT
DEUX PERSONNES POUR FAIRE L’INSTALLATION
CORRECTEMENT.
WARNING:
To reduce the risk of fire or electrical shock, do not
use this range hood with any external solid-state speed
control device. Any such alteration from original
factory wiring could result in damage to the unit
and/or create an electrical safety hazard.
AVERTISSEMENT
Pour réduire le risque d’incendie ou de choc électrique,
il ne faut pas utiliser cette hotte avec un régulateur de
vitesse électronique externe. Toute modification de ce
type du branchement d’usine peute endommager
l’appareil ou créer un risque de choc électrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
3
12"
22-1/2"
35-15/16"
35-15/16"
25"
10"
Installation Instructions
PRODUCT DIMENSIONS
Model ZV36R
Model ZV48R
Model ZV30R
CONTENTS
Product Dimensions ......................................................... 3
Installation Clearances ..................................................... 4
Optional Duct Cover Accessories .................................... 4
Installation Height, Duct Cover Accessories ................... 5
Advance Planning ............................................................. 6
Power Supply .................................................................... 6
Duct Fittings ...................................................................... 7
Tools and Materials Required .......................................... 8
Remove the Packaging ..................................................... 8
Parts Provided ................................................................... 9
Step 1, Determine Ductwork and Wiring Locations .... 10
Step 2A, Install Hood Onto Wall ................................... 11
Step 2B, Install Hood Beneath Soffit ............................ 12
Step 3, Connect Ductwork ............................................. 13
Step 4, Connect Electrical .............................................. 13
Step 5, Install Duct Covers ............................................. 13
Step 6, Install Motor ....................................................... 13
Step 7, Install Filters ....................................................... 14
Step 8, Install Backguard and Shelf............................... 14
Step 9, Install Shelf Only................................................ 15
Step 10, Install Implement Rods ................................... 15
Each hood is
shipped with a
stainless steel
backguard and a
warming shelf.
Hoods may be
installed with the
shelf or backguard
alone, or with both
as shown.
Warming
Shelf
Backguard
47-15/16"
47-15/16"
25"
10"
12"
22-1/2"
12"
22-1/2"
29-15/16"
29-15/16"
25"
10"
5
Advance Planning
DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES
Restaurant-Style Hoods Restaurant-Style Hoods
without Warming Shelf Installed with Shelf Installed1
*Possible *Possible
Actual Hood Hood
Ceiling Installation 6" Duct 12" Duct Installation 6" Duct 12" Duct
Height Height Covers Covers Height Covers Covers
7' 11" 31" 1 1 37" 1
8' 0" 32" 1 1 32" 1 1
8' 0" 38" 1
8' 1" 33" 1 1 33" 1 1
8' 2" 34" 1 1 34" 1 1
8' 3" 35" 1 1 35" 1 1
8' 4" 30" 2
8' 4" 36" 1 1 36" 1 1
8' 5" 31" 2 37" 1 1
8' 6" 32" 2 32" 2
8' 6" 38" 1 1
8' 7" 33" 2 33" 2
8' 8" 34" 2 34" 2
8' 9" 35" 2 35" 2
8' 10" 30" 1 2
8' 10" 36" 2 36" 2
8' 11" 31" 1 2 37" 2
9' 0" 32" 1 2 32" 1 2
9' 0" 38" 2
9' 1" 33" 1 2 33" 1 2
9' 2" 34" 1 2 34" 1 2
9' 3" 35" 1 2 35" 1 2
9' 4" 30" 3
9' 4" 36" 1 2 36" 1 2
9' 5" 31" 3 37" 1 2
9' 6" 32" 3 32" 3
9' 6" 38" 1 2
9' 7" 33" 3 33" 3
9' 8" 34" 3 34" 3
9' 9" 35" 3 35" 3
9' 10" 30" 1 3
9' 10" 36" 3 36" 3
9' 11" 31" 1 3 37" 3
10' 0" 32" 1 3 32" 1 3
10' 0" 38" 3
These vent hoods must be installed 30" min. to
36" max. above the standard 36" high cooking
surface. When installed with the warming shelf,
allow 32" min. to 38" max. clearance. The exact
hood installation height is determined by the
ceiling height.
1. Measure the exact ceiling height.
2. Review the chart at right to determine the
range of possible hood installation heights that
can be accomplished with one or more duct
covers.
3. Increase or decrease hood installation height to
accommodate the fixed 6" or 12" duct covers.
4. Duct covers may be stacked, in various
combinations, to reach ceiling heights.
32" Min.
38" Max.
30" Min.
36" Max.
10"
Ceiling
Height
to Floor
Duct Cover(s) Duct Cover(s)
10"
Ceiling
Height
to Floor
Note: When determining the installation height, consideration
must be given to the use of the warming shelf.
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
7
Advance Planning
DUCT FITTINGS Equivalent Quantity Total
Duct Piece Length* Used Length
10" round
to 8" round 10 ft.
Round, 1 ft.
straight (per foot
length)
1 ft.
3-1/4" x 24" (per foot
straight length)
90° elbow 15 ft.
45° elbow 9 ft.
3-14" x 12" or
3-1/4" x 24"
90° elbow 15 ft.
3-1/4" x 24"
45° elbow 9 ft.
3-1/4" x 24"
90° flat elbow 20 ft.
10" round to
3-1/4" x 24" transition 1 ft.
3-1/4" x 24" to 10"
round transition 5 ft.
10" round
to 3-1/4" x 24"
transition 90° elbow 5 ft.
3-1/4" x 24" to 10"
round transition 90° elbow 15 ft.
Round
wall cap
with damper 30 ft.
3-1/4" x 24" wall cap
with damper 30 ft.
Round
roof cap 26 ft.
Round
roof vent 24 ft.
Use this chart to compute maximum
permissable lengths for duct runs to
outdoors.
Note:
Do not exceed maximum permissable
equivalent lengths!
Maximum recommended duct
length for these hoods: 150 feet
Flexible ducting:
If flexible metal ducting is used, all
the equivalent feet values in the table
should be doubled. The flexible
metal duct should be straight and
smooth and extended as much as
possible.
Do NOT use flexible plastic ducting.
Total Duct Run
Note:
Any home ventilation system, such as a
ventilation hood, may interrupt the proper flow of
combustion air and exhaust required by fireplaces,
gas furnaces, gas water heaters and other naturally
vented systems. To minimize the chance of interruption
of such naturally vented systems, follow the heating
equipment manufacturer’s guidelines and safety
standards such as those published by NFPA and ASHRAE.
* Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces
are based on actual tests conducted by GE
Evaluation Engineering and reflect require-
ments for good venting performance with
any ventilation hood.
Hoods Are Equipped
For 10" Round Duct
*Hoods are supplied with a 10"
round transition. A locally
supplied transition is required
for other sizes.
Note:
Outlet on top of hood is
8-1/8" x 8".


Specyfikacje produktu

Marka: Monogram
Kategoria: Okap wyciągowy
Model: ZV36RSFSS

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Monogram ZV36RSFSS, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Okap wyciągowy Monogram

Monogram

Monogram ZVW8301SWSS Instrukcja

8 Października 2024
Monogram

Monogram ZVC48STSS Instrukcja

8 Października 2024
Monogram

Monogram UVC7300SLSS Instrukcja

8 Października 2024
Monogram

Monogram UVD6301DPBB Instrukcja

8 Października 2024
Monogram

Monogram UVC9300SLSS Instrukcja

8 Października 2024
Monogram

Monogram ZVC48DTB1 Instrukcja

8 Października 2024
Monogram

Monogram UVC9480SLSS Instrukcja

8 Października 2024
Monogram

Monogram UVD6301SPSS Instrukcja

8 Października 2024
Monogram

Monogram UVW7361SWSS Instrukcja

8 Października 2024
Monogram

Monogram UVD6361SPSS Instrukcja

8 Października 2024

Instrukcje Okap wyciągowy

Najnowsze instrukcje dla Okap wyciągowy