Instrukcja obsługi Milwaukee 2155-AC
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Milwaukee 2155-AC (12 stron) w kategorii Flesz. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/12
Cat. No. / No de cat.
2155-AC
ADIUS™
LED 70W TEMPORARY SITE LIGHT
LAMPE À DEL TEMPORELLE À 70 W
LÁMPARA DE TRABAJO TEMPORAL DE LED DE 70 W
OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
WARNING To reduce the risk of injury, user must read and understand operator's manual.
AVERTISSEMENT An de réduire le risque de blessures, l'utilisateur doit lire et bien
comprendre le manuel.
ADVERTENCIA Para reducir el riesgo de lesiones, el usuario debe leer y entender el manual.
2
IMPORTANT SAFETY
INSTRUCTIONS
WARNING
Read all safety warn-
ings and all instruc-
tions. Failure to follow
the warnings and instructions may result in electric
shock, re and/or serious injury. Save all warnings
and instructions for future reference.
WORK AREA SAFETY
• To reduce the risk of injury, close supervision is
necessary when an appliance is used near children.
• Store idle light out of reach of children. Warm
lights can become hazcardous in the hands of chil-
dren.
ELECTRICAL SAFETY
• Power cord plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. This product has a polarized plug (one
blade is wider than the other). This plug will t
in a polarized outlet only one way. If the plug
does not t fully, reverse the plug. If it still does
not t, contact a qualied electrician. Unmodied
plugs and matching outlets will reduce risk of electric
shock.
• Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
• Suitable for damp locations. Store indoors.
• To reduce the risk of electric shock, do not put
light in water or other liquid. Do not place or store
appliance where it can fall or be pulled into a tub or
sink.
• Secure wiring cover and hanging cable before use.
• Do not abuse the cord. Never use the cord for car-
rying, pulling or unplugging the power tool. Keep
cord away from heat, oil, sharp edges or moving
parts. Damaged or entangled cords increase the risk
of electric shock.
• Keep cords dry and o the ground. Arrange
cords carefully to avoid hazardous environ-
ments. Tripping or snagging on cords can cause
injury and product damage. Do not allow cords to
run through puddles or across wet ground.
• Do not unplug by pulling on the cord. To unplug,
grasp the plug, not the cord.
• Unplug the cord from outlet when not in use and
before servicing or cleaning.
• Always use a suitable extension cord to reduce
the risk of electric shock.
• Connect to a properly grounded outlet. If operat-
ing a light in a damp location is unavoidable, use
a ground fault circuit interrupter (GFCI) protected
supply. Use of an GFCI reduces the risk of electric
shock.
• A maximum of three 10 AWG through branch
circuit conductors suitable for 60°C permitted in
box. Suitable for Types NM and MC cable only.
•
Always install light in accordance with local and
national codes.
•
CAUTION
Do not use in hazardous locations
as required by the Canadian
Electrical Code Part 2.
PERSONAL SAFETY
• Do not overreach. Keep proper footing and bal-
ance at all times. This enables better control of the
light in unexpected situations.
• Do not use on a ladder or unstable support.
Stable footing on a solid surface enables better
control of the light in unexpected situations.
SERVICE
• Have your light serviced by a qualied repair per-
son using only identical replacement parts. This
will ensure that the safety of the light is maintained.
SPECIFIC SAFETY RULES
•Maintain labels and nameplates. These carry im-
portant information. If unreadable or missing, contact
a MILWAUKEE service facility for a free replacement.
EXTENSION CORDS
Grounded tools require a three wire extension cord.
Double insulated tools can use either a two or three wire
extension cord. As the distance from the supply outlet
increases, you must use a heavier gauge extension
cord. Using extension cords with inadequately sized
wire causes a serious drop in voltage, resulting in loss
of power and possible tool damage. Refer to the table
shown to determine the required minimum wire size.
The smaller the gauge number of the wire, the greater
the capacity of the cord. For example, a 14 gauge cord
can carry a higher current than a 16 gauge cord. When
using more than one extension cord to make up the
total length, be sure each cord contains at least the
minimum wire size required. If you are using one exten-
sion cord for more than one tool, add the nameplate
amperes and use the sum to determine the required
minimum wire size.
Guidelines for Using Extension Cords
• Be sure your extension cord is properly wired and in
good electrical condition. Always replace a damaged
extension cord or have it repaired by a qualied person
before using it.
• Protect your extension cords from sharp objects,
excessive heat and damp or wet areas.
• When stringing lights together, consider the total
Amperes draw when selecting the extension cords.
Recommended Minimum Wire Gauge
For Extension Cords*
Extension Cord Length
Nameplate
Amperes 25' 50' 75' 100' 150'
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 16.0
16.1 - 20.0
18
18
18
18
16
14
12
18
18
18
16
14
12
10
18
18
16
14
12
10
--
18
16
14
12
10
--
--
16
14
12
12
--
--
--
* Based on limiting the line voltage drop to ve volts at 150%
of the rated amperes.
READ AND SAVE ALL INSTRUCTIONS
FOR FUTURE USE.
3
GROUNDING
DANGER
Improperly connecting the ground-
ing wire can result in the risk of
electric shock. Check with a qualied electrician if
you are in doubt as to whether the outlet is prop-
erly grounded. Do not modify the plug provided
with the tool. Never remove the grounding prong
from the plug. Do not use the tool if the cord or
plug is damaged. If damaged, have it repaired by a
MILWAUKEE service facility before use. If the plug
will not t the outlet, have a proper outlet installed
by a qualied electrician.
Double Insulated Tools (Two-Prong Plugs)
Tools marked “Double Insulated” do not require ground-
ing. They have a special double insulation system which
satises OSHA requirements and complies with the
applicable standards of Underwriters
Fig. B Fig. C
Laboratories, Inc., the Canadian Stan-
dard Association and the National Elec-
trical Code. Double Insulated tools may
be used in either of the 120 volt outlets
shown in Figures B and C.
SPECIFICATIONS
Cat. No. 2155-AC ....................................................
AC Input Volts ............................................ 120-277
AC Input Watts 70 ....................................................
AC Output Volts ......................................... 120-277
Max Terminal Block Ampacity ..............................30
Wiring ....................... Romex and MC, 14-2 to 10-3
Consult with Local and National Electrical Codes
FUNCTIONAL DESCRIPTION
1. Wiring Cover
2. Cover screw
3. Cable
4. Wire clamps
5. AC input/output
6. Cable clamp
7. LED cover
123
4
5
7
6
SYMBOLOGY
Volts
Alternating Current
Electrical Shock Hazard
Read Operator's Manual
CAUTION
Bright Light -
Do Not Stare Into Light
Double Insulated
C US
UL Listing for Canada and U.S.
ASSEMBLY
WARNING
To reduce the risk of injury, always
unplug tool before changing or
removing accessories. Only use accessories
specically recommended for this tool. Others
may be hazardous.
Conversion to Permanent Wiring
WARNING! Always install light in accordance with
local codes.
To add lights in a chain, or replace the wiring:
1. Unplug the light.
2. Open the wiring cover by turning the cover screw
1/4 turn counterclockwise.
3. Remove and discard old wiring.
4. To add wiring, expose 3 to 4 inches of the wires
from the outer jacket/armor.
5. Feed the wire through the AC input/output holes, and
butt the outer jacket/armor up against the wire clamps.
6. Tighten the wire clamps using the clamping screws.
Hand tighten wire clamp screws securely to 8 lb-in.
7. Wire the lamp according to the diagrams below.
Use one side for wiring to the AC plug, and the
other for wiring to another lamp in a chain. Hand
tighten terminal block screws securely to 10 lb-in.
8. Close the wiring cover and secure by turning the
cover screw 1/4 turn clockwise.
Strain
Relief
AC Input/
Output Holes
Wire
clamps
Clamping
screws
Specyfikacje produktu
Marka: | Milwaukee |
Kategoria: | Flesz |
Model: | 2155-AC |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Milwaukee 2155-AC, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Flesz Milwaukee
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
16 Września 2024
Instrukcje Flesz
- Flesz Beko
- Flesz Gorenje
- Flesz Philips
- Flesz SilverCrest
- Flesz Toolcraft
- Flesz Nedis
- Flesz Black & Decker
- Flesz Fenix
- Flesz Garmin
- Flesz DeWalt
- Flesz Einhell
- Flesz Silverline
- Flesz Makita
- Flesz ArmyTek
- Flesz Petzl
- Flesz Knog
- Flesz Cateye
- Flesz Ledlenser
- Flesz Emos
- Flesz NightStick
- Flesz Ansmann
- Flesz Little Tikes
- Flesz Velleman
- Flesz VDO
- Flesz IVT
- Flesz Rocktrail
- Flesz Maglite
- Flesz Aluratek
- Flesz Abus
- Flesz Olympia
- Flesz Hama
- Flesz Alpen Optics
- Flesz Princeton Tec
- Flesz Duronic
- Flesz Goobay
- Flesz Trelock
- Flesz Nitecore
- Flesz Craftsman
- Flesz Olight
- Flesz Klein Tools
- Flesz Black Diamond
- Flesz PowerPlus
- Flesz Powerfix
- Flesz HiKOKI
- Flesz Dörr
- Flesz SureFire
- Flesz AccuLux
- Flesz Varta
- Flesz Spanninga
- Flesz Brennenstuhl
- Flesz Streamlight
- Flesz Nordride
- Flesz Silva
- Flesz Trebs
- Flesz Maktec
- Flesz Steren
- Flesz Livarno
- Flesz Kayoba
- Flesz Barska
- Flesz LED Lenser
- Flesz Parat
- Flesz Coleman
- Flesz Energizer
- Flesz Silva Schneider
- Flesz Tecxus
- Flesz Goal Zero
- Flesz Beghelli
- Flesz 4K5
- Flesz GP
- Flesz CEL-TEC
- Flesz Nebo
- Flesz Underwater Kinetics
- Flesz MOON
- Flesz KSE-Lights
- Flesz SuperNova
- Flesz Coast
Najnowsze instrukcje dla Flesz
15 Października 2024
11 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024