Instrukcja obsługi MGL Avionics INFO-1


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla MGL Avionics INFO-1 (24 stron) w kategorii multimetr. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/24
G-force meter
UTC and local time display
Slip indicator
Battery Voltage, *Current and Charge display
OAT display
Flight Timer & Flight log
Stopwatch
Countdown Timer
Alarm
* Requires the MGL Avionics magnetic field or active current shunt (sold separately)
Vega INFO-1
Information Display
Operating Manual – English 1.01
Vega INFO-1 Operating Manual Page 2
Introduction
The INFO-1 is a 2 1/4” sunlight readable multifunction color display instrument. The INFO-1 has the following features:
G-force meter
The INFO-1 is capable of measuring g-forces exerted in an aircraft up to +-16g. The INFO-1 also has the facility to record
the maximum positive and negative g-forces encountered (typically during a flight) in permanent memory, with a
password protected reset facility. It also features two independent cycle counters to capture the amount of times a preset
force has been exceeded. The INFO-1 is able to measure g-forces even if the instrument is not mounted exactly on the
vertical axis of the aircraft.
UTC and Local Time display
The INFO-1 is capable of displaying both UTC (as known as Zulu time) and local time to facilitate ordinary ATC time
reporting. Time is maintained by an internal lithium battery which can be replaced by the user.
Slip indicator
The INFO-1 can display a slip indicator. The slip indicator can be disabled in the menu system.
Battery Voltage, *Current and Charge display
The INFO-1 can be used to monitor your aircraft’s battery power supply. The INFO-1 is very useful in determining your
battery’s health, charging status, as well as the current load consumption of your aircraft. The INFO-1 can be used in both
12V and 24V aircraft and can measure voltages up to 30V DC.
The INFO-1 uses the MGL Avionics magnetic field or active current shunt to measure the aircrafts current load. The
INFO-1 contains a programmable low/high voltage alarm to automatically detect bad batteries and alternator failures. The
maximum and minimum voltage reached is also recorded in permanent memory.
OAT display
OAT can be shown in either degrees Celsius or degrees Fahrenheit. The INFO-1 also contains a programmable low/high
OAT alarm. The maximum and minimum OAT reached is also recorded in permanent memory.
Flight Timer & Flight log
The INFO-1 provides a 50 entry flight log that stores the start time and duration of each of the last 50 flights. The flight
timer can either be started using a front push button or from a remote input.
Stopwatch, Countdown Timer & Alarm
Stopwatch and timers can be operated simultaneously to a programmable alarm, making the INFO-1 particularly suitable
for sport flying competitions.
1 Features
1.8” high resolution 160x128, sunlight readable, wide viewing angle, 1000 cd/m2 TFT LCD display
G-force range of +-16g
Records the maximum positive and negative g-forces encountered (typically during a flight) in permanent
memory, with a password protected reset facility
Two independent cycle counters capture the amount of times a preset force has been exceeded
Able to measure G-forces even if the instrument is not mounted exactly on the vertical axis of the aircraft
Capable of displaying both UTC (Zulu time) and local time
Time is maintained by an internal lithium battery which can be replaced by the user
Can measure voltages up to 30V (compatible with both 12V and 24V aircraft supplies)
Contains a programmable low/high voltage alarm to automatically detect alternator failures and bad
batteries
Uses the MGL Avionics magnetic field or active current shunt to measure the aircrafts current load.
*Contains a charge status indicator
OAT can be shown in degrees Celsius or degrees Fahrenheit
Contains a programmable low/high OAT alarm
Provides a 50 entry flight log that stores the start time and duration of each of the last 50 flights
Vega INFO-1 Operating Manual Page 3
The flight timer can either be started using a front push button or from a remote input
Stopwatch and timers can operate simultaneously to a programmable alarm
Standard 2 1/4” aircraft enclosure (can be front or rear mounted)
Rotary control plus 2 independent buttons for easy menu navigation and user input
An external output activates when an alarm condition has been reached
Wide input supply voltage range of 8 to 30V DC with built in voltage reversal and over voltage protection
for harsh electrical environments
1 year limited warranty
* Requires the MGL Avionics magnetic field or active current shunt (sold separately)
2 Layout
F2 / Down Button:
Menu System: Softkey button
Normal Display: Mode dependent,
See section 3
Sunlight readable color
graphic display:
Backlight can be adjusted in the
menu system
Rotary Control (Up/Down) & Enter Button:
Press the rotary control during the normal display screens to access the menu system.
Rotate anti/clockwise for up/down menu scrolling. Rotate the rotary control during the
normal display mode to switch between the main display screens.
F1 / Up Button:
Menu System: Softkey button
Normal Display: Mode dependent,
See section 3
2 1/4” enclosure.
Can be front or rear mounted


Specyfikacje produktu

Marka: MGL Avionics
Kategoria: multimetr
Model: INFO-1

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z MGL Avionics INFO-1, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje multimetr MGL Avionics

MGL Avionics

MGL Avionics INFO-1 Instrukcja

20 Września 2024

Instrukcje multimetr

Najnowsze instrukcje dla multimetr

Voltcraft

Voltcraft PMM 3005-20 Instrukcja

9 Października 2024
Bearware

Bearware 306998 Instrukcja

9 Października 2024
Bearware

Bearware 307001 Instrukcja

9 Października 2024
Fluke

Fluke 283 FC Instrukcja

9 Października 2024
Noyafa

Noyafa NF-5330C Instrukcja