Weighing Setup: For more precision / shorter stability time
On
Off
Example
On
Off
G
H
B
C C C
D
XP Balance
I
XS Balance
Short Operating Instructions
For further information, please refer to the operators Manual
METTLER TOLEDO
XP / XS Analytical- and Precision Balances
Basic Functions:
Switching on
and off
Display
1. Switch on display:
Press the « » On/Off
key briefly. The display
performs a test and is
then ready to weigh.
2. Switch off Display;
Press and hold the
« » key until the On/Off
message “OFF” ap-
pears in the display.
The display then fades
and the balance is
switched off.
User Profile: *only XP
Choose
User Profile
This key can be used to
call up the desired user
profile. Different settings
can be stored in a user
profile.
Zero
Display
Zero ing: Pres s the
« » to set a new G
zero point.
Always use the « » G
before you start the
weighing procedure.
Tare
Display
Taring: If you work with
a Tare container, first
zero the balance. Then
put the Tare container
on the balance and
press « », to tare H
the balance.
Weighing-
Applications
Choose the applica-
tion: If you want to
change the application,
then press the applica-
tion menu button and
choose another ap-
plication.
Levelling, Internal
Adjustment
(Factory setting)
1. Level indicator is built-
in in the device.
2. Level indicator is not
centered.*
3. Release the clamps.*
4. Levelling. After this pro-
cess, lock the clamps
again.*
5. Internal Adjustment
Pressing this function
key triggers a balance
adjustment using the
bui lt-in cali bra tio n
weight. This can be
implemented at any
time.
*
depending on balance
Weighing filters:
Weighing mode
1. Choose System-Set-
up
2. Define Weighing pa-
rameters
3. Define the Weighing
mode
Advise:
Solids:
«Universal»
Powder, Liquid:
«Dosing»
Weighing filters:
Environment
1. Choose System-Set-
up
2. Define Weighing pa-
rameters
3. Define Environment
Advise:
Fume cupboard – un-
stable weighing table:
«
Unstable»,
«Very unstable»
Stable Weighing table,
no drafts
«Standard», «Stable»
Weighing filters:
Value Release
1. Choose System-Set-
up
2. Define Weighing pa-
rameters
3. Define Value Release
Advise:
Highest Precision:
«Very reliable»
Fast Value Release:
«Very fast»,
but less precision
Test:Additional Functions:

EXCELLENCE PLUS
One touch
- change the time
On touch
- e.g. start the internal adjustment
On touch
- e.g. start the internal adjustment
METTLER TOLEDO Excellence Plus and Excellence Balances
Overview of the Terminal XP Analytical- and Precision balances:
XP Display Ter-
minal
1. Button SmartSens:
Each of these two
contact-free sensors
can be assigned a key
or menu function.
2. Button Home:
This key can be used
to return to the “Home”
user profile from any
menu level in any
application.
3. Button User profile:
This key can be used
to call up the desired
user profile. Different
settings can be stored
in a user profile.
1
4
6
7
8
4. Status bar:
If the left or right
SmartSens is as-
signed a key func-
tion, then the cor-
responding symbol
is highlighted.
5. System-Setup:
Define the basic
settings.
6. Select the applica-
tion.
7. Button Applications-
Setup:
Each application
can be optimized
to the current task
using a number of
settings.
8. Printer:
Pressing this key
transmits data via
the interface.
XS Display Ter-
minal
1. Button Home:
This key can be used
to return to the “Home”
user profile from any
menu level in any
application.
2. Weighing application:
By pressing this symbol
you can choose the
desired application.
3. Button Applications-
Setup:
Each application can
be ideally adapted to
the current task using
a number of settings.
3
4
4. Printer:
Pressing this key
transmits data via
the interface.
Overview of the Terminal XS Analytical- and Precision balances:
© Mettler-Toledo AG 2008 11781027 Printed in Switzerland 0807/7.12
Mettler-Toledo AG, Laboratory & Weighing Technologies, CH-8606 Greifensee, Switzerland
Phone +41-44-944 22 11, Fax +41-44-944 30 60, Internet: http://www.mt.com
*11781027*
1
2
3
4
5
1
2
Specyfikacje produktu
Marka: | Mettler-Toledo |
Kategoria: | waga |
Model: | XS |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Mettler-Toledo XS, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje waga Mettler-Toledo

23 Września 2024

20 Września 2024

20 Września 2024

17 Września 2024

14 Września 2024

6 Września 2024

30 Sierpnia 2024

30 Sierpnia 2024

18 Sierpnia 2024

16 Sierpnia 2024
Instrukcje waga
- waga AEG
- waga Beurer
- waga Sanitas
- waga Caso
- waga Xiaomi
- waga Gorenje
- waga LERAN
- waga Tefal
- waga Voltcraft
- waga SilverCrest
- waga Nokia
- waga Withings
- waga Nedis
- waga Medion
- waga Black & Decker
- waga Adler
- waga Marquant
- waga Toshiba
- waga Tesla
- waga Domo
- waga Conair
- waga Ardes
- waga Orbegozo
- waga Blaupunkt
- waga Grundig
- waga Hyundai
- waga Rowenta
- waga Mesko
- waga Concept
- waga ECG
- waga TFA
- waga Zelmer
- waga Medisana
- waga Emerio
- waga Create
- waga Tanita
- waga Melissa
- waga Beper
- waga Eufy
- waga Perel
- waga Izzy
- waga Velleman
- waga Witt
- waga Manta
- waga Pyle
- waga Eta
- waga Camry
- waga Scarlett
- waga Zeegma
- waga Nevir
- waga TriStar
- waga Digi
- waga Clatronic
- waga Tronic
- waga Inventum
- waga Innoliving
- waga Hama
- waga Taylor
- waga Duronic
- waga Terraillon
- waga VOX
- waga Gemini
- waga Lanaform
- waga Sencor
- waga ADE
- waga Etekcity
- waga Grunkel
- waga Becken
- waga Haeger
- waga Kern
- waga Vitek
- waga Maestro
- waga Ecomed
- waga Salter
- waga Renpho
- waga OBH Nordica
- waga Bestron
- waga Optimum
- waga ACME
- waga Korona
- waga Saturn
- waga Jata
- waga Logik
- waga Profilo
- waga Termozeta
- waga Eldom
- waga Maxxmee
- waga GOTIE
- waga Soehnle
- waga Escali
- waga Under Armour
- waga Exacta
- waga Ufesa
- waga Imetec
- waga Gerlach
- waga AWS
- waga Active Era
- waga Xavax
- waga Balance
- waga Dexford
- waga Barazzoni
- waga Waves
- waga Guardo
- waga Mybeo
- waga Satex
- waga W8 Brunner Gasflesweegschaal
- waga ATP
Najnowsze instrukcje dla waga

13 Stycznia 2025

13 Stycznia 2025

13 Stycznia 2025

13 Stycznia 2025

13 Stycznia 2025

12 Stycznia 2025

12 Stycznia 2025

24 Października 2024

15 Października 2024

15 Października 2024