Instrukcja obsługi Mean Well TS-1500-248B


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Mean Well TS-1500-248B (20 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/20
TN/TS-1500
Inverter Instruction Manual
Index
TN/TS-1500 Instruction ManualInverter
1. Safety Guidelines 1
1
2
2
3
3
5
9
12
14
12
13
4
3
4
5
6
8
9
9
10
12
2. Introduction
3. User Interface
4. Explanation of Operating Logic
5. Initial Setup of TN/TS-1500
6. Protection
7. Installation & Wiring
8. Failure Correction Notes
9. Warranty
2.1 Features
3.2 LED Indicator on Front Panel
3.1 Front Panel
2.2 Main Specification
2.3 System Block Diagram
3.3 Functional Indication and Alarm
3.4 Rear Panel
4.1 Explanation of UPS Mode Control Logic
4.2 Explanation of Energy Saving Mode Control Logic
5.1 Initial State
5.2 Initial Set Point for Transition Voltages
5.3 Procedure of Setting Operating Mode, Output Voltage,
5.4 Remote Monitoring Software
Frequency, and Saving Mode
6.1 Input Protection
6.2 Output Protection
...............................................................................
........................................................................................
........................................................................................
........................................................................
..................................................................
......................................................................................
....................................................................................
......................................................
................................................
....................................................................................
..................................................................................
...............................................................
......................................................
.......................................................
...........................................................................................
...........................................................................
........................................................................
..........................................................................
...................................................................
.............................................................................................
.....................................
........................................................
....................................
...................
17
17
Jun. 2019 Version 21
1
1.Safety Guidelines (Please read through this manual before assembling
TN/TS-1500)
Risk of electrical shock and energy hazard. All failures should be examined by
the qualified technician. Please do not remove the case of the inverter by
After connecting the AC input of the inverter to the utility, the AC outlet of the
It is highly recommended to mount the unit horizontally.
Please do not install the inverter in places with high moisture or near water.
Please do not install the inverter in places with high ambient temperature or
Please only connect batteries with the same brand and model number in one
Never allow a spark or flame in the vicinity of the batteries because they may
Make sure the air flow from the fan is not obstructed at both sides (front and
Please do not stack any object on the inverter.
yourself!
inverter will have AC output even if the power switch on the front panel is in the
OFF position.
under direct sunlight.
battery bank. Using batteries from different manufacturers or different capacity
generate explosive gases during normal operation.
back) of the inverter. (Please allow at least 15cm of space)
is strictly prohibited!
Inverter Inverter
Inverter
Inverter
Don't
disassemble
Away from
moisture
Away from fire or
high temperature
Don't stack on
the inverter
Keep good
ventilation
Please do not turn on the inverter before start the engine if inverter connect to
vehicle’s battery directly.
Fully digital controlled by an advanced CPU, TN-1500 is a true sine wave
TS-1500 series only possess the inverter function. It uses batteries as the input
inverter equipped with an AC charger and solar charger. It can also operate
source and converts the energy into AC output.
under UPS and Energy saving modes. (Descriptions which are high lighted
represents functions only for the TN-1500 series)
2.Introduction
WARNING:
It is suggested to execute regular battery maintenance
Batteries will have aging problem after years of operation.
(e.g. every year). Once aged, the batteries should be changed
by professional technician, or the failed batteries may cause
fire or other hazards.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(a) This device may not cause harmful interference, and
(b) this device must accept any interference received, including interference that
may cause undesired operation.


Specyfikacje produktu

Marka: Mean Well
Kategoria: Niesklasyfikowane
Model: TS-1500-248B

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Mean Well TS-1500-248B, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Mean Well

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024