Installaon Manual
Type
DRA DIN rail power supply Series DRA-40, DRA-
60
DRA- - INPUT: -240VAC 0.8A 50/60Hz OUTPUT: V 3.34A 40 12 100 12
DRA- - INPUT: -240VAC 0.8A 50/60Hz OUTPUT: V 1.7A 40 24 100 24
DRA- - INPUT: -240VAC 1.3A 50/60Hz OUTPUT: V 5A 60 12 100 12
DRA- - INPUT: -240V 1.3A 50/60Hz OUTPUT: V 2.5A 60 24 100 AC 24
Introducon
DRA is a DIN rail power supply series featuring adjustable output current. Users are able to set its output current to
a range of 10% - 100% of rated current via 1-10Vdc, PWM signal or resistance. Like other Mean Well s DIN series,
they can be mounted on a TS35 Standard DIN rail.
Installaon
( )1 Always allow good venlaon clearances, 5mm le and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheang. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
( )2 The appropriate mounng orientaon for the unit is vercal, the input terminals the bottom and output on at
the top. Mounng orientaons other than that, such as upside down, horizontal, or table-top mounng, is not
allowed.
( )3 Use copper wire only, and recommended wires are shown as below.
AWG
18
16
14
12
Rated Current of
Equipment (Amp)
7
10
15
20
Cross-secon of
Lead(mm2 )
0.8
1.3
2.1
3.3
Note Current each wire carries should be de-rated to 80% of the current suggested
above when using 4-6 wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connecon and the screw terminals are
securely xed to prevent poor contact. If the power supply possesses mul-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
( )4 Use wires that can withstand temperatures of at least 80°C, such as UL1007.
( )5 Recommended wire strapping length m (0.197 . is 5m ”)
( )6 Recommended screwdriver is 3 , sloed type.mm
( )7 The recommended torque seng for terminals(TB1) is 5 kgf‐cm (4.4 Lb‐in),
terminals(TB2) is 5 5 .8 kgf‐cm ( Lb‐in).
( )8 Each unit requires 0.15mA when dimming funcon is used. Please make sure your controller is capable of
driving the units.
Installaon Manual
3
1
2
( )9 Suggested fuse and maximum number of the DRA that can be connected to a circuit breaker at 230V are shown
as below.
Model
Fuse
Circuit breaker
C16
D 16
DRA- 40
T2.5A/L250V
11
21
DRA- 60
T2.5A/L250V
8
16
( )10 Mounng Instrucon
Mount as shown in gure only, with input terminals down, or else sucient cooling will not be possible.
Admissible DIN railTS35/7.5 or TS35/15
For rail fastening
( )a Tilt the unit slightly rearwards.
( )b Fit the unit over top hat rail.
( )c Slide it downward unl it hits the stop.
( )d Press against the bottom for locking.
( )e Shake the unit slightly to check the locking acon.
( )11 For other informaon about the products, please refer to www.meanwell.com for details.
Warning / Cauon !!
( )1Risk of electrical shock and energy hazard. All failure should be examined by a qualied technician. Please do
not remove the case of the power supply by yourself!
( )2Risk of electric arcs and electric shock (danger to life). Connecng both t primary and the secondary sides he
together is not allowed.
( )3Risk of burn hazard. Do not touch the unit in operaon and shortly aer disconnecon!
( )4 Risk of re and short circuit. The openings should be protected from foreign objects or dripping liquids.
( )5 Only install the unit in a polluon degree 2 environment (Note.1).
( )6 Please do not install the unit in places with high moisture or near the water.
( )7The maximum operang temperature is 45 for the DRA- - , for the DRA- -24, DRC-60A and °C 60 12 50°C 60
DRC-60B, for the DRA- -12/24, DRC-40A and DRC-40B, please do not install the unit in places with high 55°C 40
ambient temperature or near re source.
( )8 The FG ( ) must be connected to (Protecve Earth). PE
( )9 Output current and output waage must not exceed the rated value on its specicaon.
"Click"
Installaon Manual
( )10 Disconnect system from supply voltage:
Before commencing any installaon, maintenance or modicaon work: Disconnect your system from
supply voltage. Make sure that inadvertent connecon in circuit will be impossible!
Note.1: Polluon Degree 2 applies where there is only non-conducve polluon that might temporarily become
conducve due to occasional condensaon. Generally refer to dry, well-venlated locaons, such as
control cabinets.
Manufacturer
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Oce
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: + - -758-6000 31 20
Web: www.meanwell.eu


Specyfikacje produktu

Marka: Mean Well
Kategoria: Niesklasyfikowane
Model: DRA-40-12

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Mean Well DRA-40-12, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Mean Well

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024