Instrukcja obsługi Maytag WVU17UC0JB

Maytag Okap wyciągowy WVU17UC0JB

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Maytag WVU17UC0JB (24 stron) w kategorii Okap wyciągowy. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/24
RANGE HOOD SAFETY
30" (76.2 CM) RANGE HOOD
Installation Instructions and Use & Care Guide
For s ons out fe re eratio erforma e, part acce ories or rvice, ca que ti ab atu s, op n/p nc s, ss se ll: 1-800-253-1301
or v it our website at is www.wh l o comir po l.
In da bs at Cana , call or v it our we1-800-807-6777 is ite www.wh poo cairl l.
HOTTE DASPIRATION DE
30" (76,2 CM)
Instructions dinstallation et Guide dutilisation et dentretien
Au Ca po a i an in a a on servic co oser nada, ur ss st ce, st ll ti ou e, mp
le ou visiter notre site Web à1-800-807-6777
www.wh poo airl l.c
Table Tof Contents/ abl tiè .. .. .. .. ..e des ma res . . . ... ... .. .. .. .. .. .. ... . ... . . . ... ... .. .. .. .. .. ... . ... . . . ... . ..2.. ..
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
LIB0159236A/W11367653B
Y can be ed or seriousl i u oou kill y ured inj f yo d n't imme te dia ly
You can be killed or seriously injured if you don't follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
Models/Modèles:
WVU17UC0JS ,
WVU17UC0JB,
WVU17UC0JW
2
TABLE OF CONTENTS
RA ODNGE HO SAFETY ..................................................... ...... .... . .1
INSTALL ...... ...... ...... ......A S ..TION REQUIREMENT . . . ....... ...... .... . .3
INSTALL ... ...... ...... ...... ...... ...... ...... ...A STION INSTRUCTION . . . . . . . .6
RA ODNGE HO USE......................................................................10
RA ODNGE HO CARE.................................... ...... ...... ...... ....... . . . ...10
WIRING DIAGRA ..... ...... ...... ...... ...... ...... M . . . . . ....... ...... ...... ....... . . ...11
ASSISTANCE ..... ...... ...... ...... ...... ...... ...... ...... EOR SERVIC . . . . . . . ...12
WARRANT .. ...... ...... ...... ...... ...... ......Y . . . . . . ....... ...... ...... ...... ....... . . . ...13
TABLE DES MATIÈRES
CURI DE LA HOTTE DE CUISINIÈR E................................14
EXIGENCES D’INSTALLATION............... ...... ...... ...... ...... ....... . . . . .16
INSTRUCTIONS D’INSTALLATION................ ...... ...... ...... ....... . . . .20
UTILISATION DE LA HOTTE .......................................................24
ENTRETIEN DE LA HOTTE..........................................................24
SCMA DE CÂBLAGE...............................................................25
ASSISTANCE OU SERVICE................................................. ....... .26
GARANTI ...... ...... ...... ...... ...... ...... ...... ...... ...... ......E. . . . . . . . . . ....... ....... .27
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNIN G: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
Do not operate any fan with a damaged cord or plug.
Discard fan or return to an authorized service facility for
examination and/or repair.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling; do not damage
electrical wiring and other utilities.
Ducted fans must always be vented outdoors.
CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into
spaces within walls or ceilings, attics or into crawl spaces,
or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:a
SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may be burned.
DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
Use an extinguisher ONLY if:
– You know you have a class ABC extinguisher, and you
already know how to operate it.
– The fire is small and contained in the area where it
started.
– The fire department is being called.
– You can fight the fire with your back to an exit.
aBased on "Kitchen Fire Safety Tips" published by NFPA.
WARNING: To reduce the risk of fire or electrical shock,
do not use this fan with any solid-state speed control
device.
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Re ll e ct pr wi any list ad and fo ow th instru ions ovided th tools ed
here.
Tools needed
For 3¹⁄₄" x 10" 3 x 25.4 r ngular vented installations(8. cm) ecta
Optional accessories
* i i orde ist For nformat on on ring, see the Ass ance or Service”
section.
Location Requirements
IMPORTANT: serve l verning s and or nances.Ob al go code di
It is ins al the t ler’s re nsi ty th spo bili to comply wi installation
clearanc ecif e model/serial rating plate. The es sp ied on th
model/serial rating plate is located inside the range hood on
the le wa ft ll.
Range hood location should be aw fray om strong draft areas,
such as windows, doors and strong heating vents.
Cabi t n nsio t t are wn mu be used. ne ope ing dime ns ha sho st
Given dimensions provide minimum ear nc Co ult th cl a e. ns e
cooktop/range manufacturer installation instructions before
making any cutouts.
This range hood is recommended for use with cooktops with
a maximum total rating of 40,000 Bt us or ssle .
Gr ed elec al l re ir . See l trical ound tric out et is qu ed “E ec
Re r n ct n.qui eme ts” se io
Al ope ings in ceil ng and wall range hood ll bel n i where wi
installed must be sealed.
These range hoods are factory set for vented installations.
Models that are capable of being i talled as non-vented ns
(recirc a require c rcoal f ers e t nce ul ting) ha ilt . Se he “Assista or
Serv ce” se tion for in rm tio on ng ch co fi tersi c fo a n orderi ar al l .
For bMo ile Ho me Install tiona s
The installation of this range hood st conform to the mu
Ma fac red e ns t fe n rd t 24 nu tu Hom Co truc ion Sa ty Sta da s, Ti le
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Constr on and Safetucti y, ti 24, t 2 n su tle HUD, Par 80) or whe ch
sta da is not applicable, then rd st ard for u ctured e and Man fa Hom
Inst ll tion 19 (Ma uf ct ed Home Sit s, Communi iesa a 82 n a ur e t and
Se ps) ANSI A22 /NFtu 5.1 PA 5 latest ed01A, or ition, or with local
codes.
Caulking gun and weatherproof
caulking compound
Jigsaw or yhole sawke
Flat-blade
screwdriver
Drill with " ¹⁄₈
(3 mm), ¹⁄₂"
(13 mm)
and 1¹⁄₄"
(3 cm) bits
Wire stripper
#2 Phillips
screwdriver
Metal snips
Pencil
Parts supplied
Remove parts from package. Check that all parts are included.
Parts needed
#8-18 x "
(4.2 x 16 mm)
truss-head screws
#8-18 x 1"
(4.2 x 25 mm)
flat-head screws
Drywall
anchors
Mounting
brackets
7" (17.8 cm) round vent
mounting plate
Part Number W10388168*
UL Listed/CSA
Approved
wire connectors
120V, 9W
maximum,
type E26
lamp
3¹⁄₄" x 10"
(8.3 x 25.4 cm) rectangular
metal vent system with
wall or roof cap
Duct tape
Power
cord kit
Part Number
W10355452*
Stainless steel
cleaner and
polish
Part Number
31462A*
For 7" (17.8 cm) round vented installations
7" (17.8 cm) round
metal vent system with
wall or roof cap
7" (17.8 cm)
round damper
Part Number
W10355451*
Vent clamps as
required
Recirculating
kit (Charcoal
filter)"
Part Number
W11371717


Specyfikacje produktu

Marka: Maytag
Kategoria: Okap wyciągowy
Model: WVU17UC0JB

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Maytag WVU17UC0JB, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Okap wyciągowy Maytag

Maytag

Maytag UVL6048JSS Instrukcja

15 Października 2024
Maytag

Maytag WVW57UC0FS Instrukcja

25 Września 2024
Maytag

Maytag UXT4136ADS Instrukcja

25 Września 2024
Maytag

Maytag UXT4230ADB Instrukcja

25 Września 2024
Maytag

Maytag UXT4030ADS Instrukcja

25 Września 2024
Maytag

Maytag UXD8630DYS Instrukcja

25 Września 2024
Maytag

Maytag WVI75UC6DS Instrukcja

25 Września 2024
Maytag

Maytag UXT5530AAS Instrukcja

25 Września 2024
Maytag

Maytag UXT4136ADB Instrukcja

25 Września 2024
Maytag

Maytag UXT4236ADB Instrukcja

25 Września 2024

Instrukcje Okap wyciągowy

Najnowsze instrukcje dla Okap wyciągowy

Pelgrim

Pelgrim ISW990 Instrukcja

15 Października 2024
PKM

PKM 6080X Instrukcja

15 Października 2024
M-System

M-System MSPK 761 IX Instrukcja

15 Października 2024
Pelgrim

Pelgrim ISWA991RVS Instrukcja

15 Października 2024
Pelgrim

Pelgrim ISW751RVS Instrukcja

15 Października 2024
Pelgrim

Pelgrim ISW771RVS Instrukcja

15 Października 2024
Amana

Amana WVW53UC6HV Instrukcja

15 Października 2024
Haier

Haier HPH60IMB2 Instrukcja

15 Października 2024
Haier

Haier HC60BMB2 Instrukcja

15 Października 2024
Haier

Haier HPH90IMB2 Instrukcja

15 Października 2024