Instrukcja obsługi Mastervolt Digital AC 1x6A

Mastervolt Ładowarka baterii Digital AC 1x6A

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Mastervolt Digital AC 1x6A (24 stron) w kategorii Ładowarka baterii. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/24
USERS MANUAL / GEBRUIKERSHANDLEIDING
BETRIEBSANLEITUNG / MANUEL D’UTILISATION
MANUAL DE UTILIZACION / INSTRUZIONI PER L’USO
Digital AC 1x6A
AC relay for digital switching
MASTERVOLT
Snijdersbergweg 93,
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
Fax.: +31-20-6971006
mastervolt.com
ENGLISH: PAGE 1
NEDERLANDS: PAGINA 5
DEUTSCH: SEITE 9
FRANÇAIS: PAGINA 13
CASTELLANO: PÁGINA 17
ITALIANO: PÁGINA 21
MAS_TL_001_0211
Copyright © 2011 Mastervolt v 2.1 January 2011
2
1 GENERAL INFORMATION
1.1 Use of this manual
Copyright © 2011 Mastervolt. All rights reserved.
Reproduction, transfer, distribution or storage of part or
all of the contents in this document in any form without
the prior written permission of Mastervolt is prohibited.
This manual serves as a guideline for the safe and
effective operation of the Digital AC 1x6A.
Keep this manual at a secure place!
1.2 Guarantee specications
Mastervolt guarantees that this product was built
according to the legally applicable standards and
stipulations. If you fail to act in accordance with the
regulations, instructions and stipulations in this user’s
manual, damage can occur and/or the product will
not full the specications. This may mean that the
guarantee will become null and void.
IMPORTANT: The standard guarantee period is two
years after date of purchase.
1.3 Liability
Mastervolt can accept no liability for:
Consequential damage due to use of the Digital AC
1x6A;
Possible errors in the manuals and their results;
Use that is inconsistent with the purpose of the
product.
CAUTION!
Never remove the identication label.
2 OPERATION
2.1 MasterBus functions
The Digital AC 1x6A operation is entirely MasterBus
based. See www.mastervolt.com for information about
MasterBus and the MasterBus event structure. The
table below shows the relay functions.
Monitoring Description Default Range
State Relay can be switched On (active) or Standby Standby Standby / Active
Control Change the state of the relay Standby Active / Standby
Conguration
General
Language Set the MasterBus Digital AC menu language English See specications
Device name Any name you wish with 12 characters max AC Relay 12 characters max
Event locked Check box for installers to lock event conguration.
Only operable by installers.
Unchecked Unchecked / Checked
Conguration Timing
Min. runtime Check box to enable the function Minimum runtime
for switching the relay.
Unchecked Unchecked / Checked
Min. runtime Minimum runtime setting 15 minutes 1-65535 minutes
Max. runtime Check box to enable the function Maximum runtime
for relay switching the relay.
Unchecked Unchecked / Checked
Max. runtime Maximum runtime setting 480 minutes 1-65535 minutes
Event commands
Activate The Digital AC 1x6A can be switched On (activate)
or Standby.
— —
MPC stop MPC (Maximum Power Control) prevents a power
source from being overloaded. At MPC stop the AC
1x6A disconnects the load.
— —
MPC reduce At the end of MPC reduce the AC 1x6A reconnects
the load.
— —
January 2011 / Digital AC 1x6A / EN
3
3 INSTALLATION
3.1 Overview
Insert the MasterBus cables, then connect the relay
cables to the screw terminal input and output, see below.
Functional scheme of the Digital AC 1x6A
3.2 Installation schemes
The Digital AC 1x6A is suitable for switching AC currents
up to 6A. For currents above 6A you need an external
relay which is controlled by the AC 1x6A.
You also need to add a fuse like shown for
load protection.
1. Input
2. Output (normally open)
3. Communication LED, illuminating when the
state is “activate” MasterBus connector
Function:
Standby: Relay is open,
Activate: 1 is connected to 2,
Maximum relay current: 6A
External relay
Installation schemes for currents up to 6A and above
EN / Digital AC 1x6A / January 2011

Specyfikacje produktu

Marka: Mastervolt
Kategoria: Ładowarka baterii
Model: Digital AC 1x6A

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Mastervolt Digital AC 1x6A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Ładowarka baterii Mastervolt

Instrukcje Ładowarka baterii

Najnowsze instrukcje dla Ładowarka baterii

MSW

MSW S-CHARGER-20A.2 Instrukcja

15 Października 2024
MSW

MSW S-CHARGER-10A.2 Instrukcja

15 Października 2024
Intenso

Intenso Powerbank 10400 Instrukcja

14 Października 2024
Gembird

Gembird CHM-03 Instrukcja

10 Października 2024
Kostal

Kostal IQ 8.5 Instrukcja

9 Października 2024
Venom

Venom VS5007 Instrukcja

9 Października 2024
Venom

Venom VS5010 Instrukcja

9 Października 2024
Venom

Venom VS2891 Instrukcja

9 Października 2024
Venom

Venom VS2881 Instrukcja

9 Października 2024
Venom

Venom VS2883 Instrukcja

9 Października 2024