Instrukcja obsługi Master 140TMHD-KFA

Master Podgrzewacz 140TMHD-KFA

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Master 140TMHD-KFA (14 stron) w kategorii Podgrzewacz. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/14
MODEL NUMBERS:
140TMHD-KFA / 190TMHD-KFA / 215TMHD-KFA
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure
to comply with the instructions and warnings provided with this heater. Failure to comply
can result in fire or explosion that can cause property loss, bodily injury, or loss of life. Only
persons who can follow and understand these instructions should operate or service this
heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle
Climate Technologies at 800-641-6996.
DANGER
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED
SPACES WITHOUT ADEQUATE VENTILATION. THIS HEATER
IS SUITABLE FOR OUTDOOR USE, AND INDOOR USE ONLY
IN WELLVENTILATED AREAS. INDOOR USE PERMITTED ONLY FOR: THE TEMPORARY
HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER
CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented portable heater that uses air
(Oxygen) from within the area in which it is used. Failure to provide adequate combustion and
ventilation air will result in asphyxiation, carbon monoxide poisoning, bodily injury or death.
Refer to “Ventilation” on Page 6.
FACTORY ID: 500
DANGER
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
© 2023 Pinnacle Climate Technologies, Inc. MAKB-440Master is a registered trademark of Pinnacle Climate Technologies, Inc.
User’s Manual &
Operating Instructions
KEROSENE FORCED
AIR HEATER
IN
IN
IN
INDUSTR
DUSTR
DUSTR
DUSTRIA
IA
IA
IAL
L
L
L
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Example:
150812779. Have your Serial Number ready before calling customer service at 800-641-6996.
WARNING: PERSONS WHO ARE IMPAIRED OR UNDER THE INFLUENCE
OF ALCOHOL OR DRUGS SHOULD NOT OPERATE HEATER.
2
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2023 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
MASSACHUSETTS RESIDENTS: Massachusetts state law prohibits the use of this heater in
any building which is used in whole or in part for human habitation. Use of this heating device
in Massachusetts requires local fire department permit (M.G.L.C. 148, Section 10A).
NEW YORK CITY RESIDENTS: The New York City Fire Code prohibits the storage, handling
and use of kerosene fueled heaters for space heating. Any person violating that provision may
be punished by a fine up to $10,000 and a term of imprisonment of up to 6 months.
Look for this icon throughout the manual for helpful tips on how to assemble, use and
clean your KFA Heater.
THE INSTALLATION OF THE EQUIPMENT SHALL BE IN ACCORDANCE WITH THE
REGULATION OF AUTHORITIES HAVING JURISDICTION AND CSA STANDARD B139.
WARNING: This product can expose you to chemicals, including leadand lead
compounds, whichareknown to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED.
DO NOT START THE HEATER WHEN THE CHAMBER IS HOT.
WARNING
WARNING
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep com-
bustibles such as; building materials, paper or cardboard a safe dis-
tance away from the heater as recommended by these instructions.
Never use the heater in spaces which contain products such as; gasoline, solvents, paint
thinners, dust particles, volatile or airborne combustibles or any unknown chemicals. This is
an unvented portable heater. It uses air (Oxygen) from the area in which it is used. Adequate
combustion and ventilation air must be provided. Refer to “Ventilation” on page 6. Bulk fuel
storage should be a minimum of 25 feet (7.6 m) from heater.
WARNING
DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND
THOROUGHLY UNDERSTAND THESE SAFETY AND OPERATING
INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with
this heater can result in death, serious bodily injury, property loss or damage from the hazards of
fire, soot production, explosions, burns, asphyxiation or carbon monoxide poisoning. Only per-
sons who can read and understand these instructions should use or service this heater.
WARNING
SAFETY INFORMATION
Safety Information.......................................................2-3
What’s in the Box.............................................................4
Specifications...................................................................5
Features..
.........................................................................
5
Assembly Instructions....................................................5
Operation......................................................................6-7
Maintenance.................................................................8-9
Wiring Diagrams............................................................10
Troubleshooting Guide.................................................11
Exploded View
.........................................................
...
.
.12
Parts List...........................................................................13
Limited Warranty.............................................................14
TABLE OF CONTENTS
3
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2023 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
SAFETY INFORMATION CONT.
ALWAYS use only the electrical power (voltage and
frequency) specied on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and
extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
NEVER use fuels such as gasoline, benzine, paint
thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the heater
is operating or still hot. This heater is EXTREMELY
HOT while in operation.
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
140T-190TMHD-KFA 215TMHD-KFA
Top 4 ft. (122 cm) 4 ft. (122 cm)
Sides 4 ft. (122 cm) 4 ft. (122 cm)
Front 8 ft. (244 cm) 10 ft. (305 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it
is plugged in, it can start at anytime in accordance
with the thermostat setting.
RISK OF BURNS,
FIRE AND
EXPLOSION!
RISK OF ELECTRIC
SHOCK!
WARNING
WARNING
CAUTION! HOT
WHILE IN OP-
ERATION. DO
NOT TOUCH. KEEP CHILDREN, ANIMALS,
CLOTHING AND COMBUSTIBLES AWAY
FROM HEATER.
WARNING
The products described in this manual are
kerosene direct-fired, forced air heaters. Kerosene
forced air heaters are primarily intended for use for
temporary heating of buildings under construction,
alteration or repair. Direct-fired means that all
of the combustion products of the heater enter
the heated space. This appliance is rated at 98%
combustion eciency, but does produce small
amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation
in accordance with the instructions in this
manual can result in death.People with breathing
problems should consult a physician before
using this heater. Early signs of carbon monoxide
poisoning resemble the flu. Symptoms of improper
ventilation/carbon monoxide poisoning are:
Headache Dizziness Nausea Dry Mouth Sore
Throat Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater
serviced and check for proper ventilation. Some
people are more aected by carbon monoxide
than others. These include: pregnant women, those
with heart or lung problems, anemia or those under
the influence of alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED
ONLY FOR: The temporary heating of adequately
ventilated buildings or structures under
construction, alteration or repair. Provide at
least a three square foot (2,800 sq cm) opening
of outside air for every 100,000 Btu/Hr (29 kW)
heater rating. Refer toVentilation” on page 6 for
further instructions.
RISK OF INDOOR
AIR POLLUTION!
WARNING
CARBON
MONOXIDE
POISONING MAY
LEAD TO DEATH!
DANGER


Specyfikacje produktu

Marka: Master
Kategoria: Podgrzewacz
Model: 140TMHD-KFA

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Master 140TMHD-KFA, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Podgrzewacz Master

Master

Master MH-400T-KFA Instrukcja

9 Października 2024
Master

Master MH-05-240-GH Instrukcja

9 Października 2024
Master

Master MH-80TBOA-OFR Instrukcja

9 Października 2024
Master

Master MH-53-240 Instrukcja

9 Października 2024
Master

Master 190TMHD-KFA Instrukcja

9 Października 2024
Master

Master MH-80TBOA-KFA Instrukcja

9 Października 2024
Master

Master 140TMHD-KFA Instrukcja

9 Października 2024
Master

Master 150VMHD-GFA Instrukcja

8 Października 2024
Master

Master BLP 53ET Instrukcja

29 Września 2024
Master

Master BV 400 Instrukcja

24 Września 2024

Instrukcje Podgrzewacz

Najnowsze instrukcje dla Podgrzewacz

Jotul

Jotul F 361 Instrukcja

15 Października 2024
Adler

Adler AD 7752 Instrukcja

15 Października 2024
MSW

MSW -TTEH-3000 Instrukcja

15 Października 2024
MSW

MSW IR-DRYER2000.2 Instrukcja

15 Października 2024
MSW

MSW IR-DRYER3000.1 Instrukcja

15 Października 2024
MSW

MSW IR-DRYER2000.1 Instrukcja

15 Października 2024
MSW

MSW IR-DRYER3000.2 Instrukcja

15 Października 2024
MSW

MSW -CHEH-3300 Instrukcja

15 Października 2024
MSW

MSW -CTEH-15000 Instrukcja

15 Października 2024