Instrukcja obsługi Makita HP1631K
Makita
Wiertarki udarowe
HP1631K
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Makita HP1631K (11 stron) w kategorii Wiertarki udarowe. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/11
1
ENGLISH (Original instructions)
INSTRUCTION MANUAL
DOUBLE INSULATION
IMPORTANT: Read Before Using.
Hammer Drill
HP1630
HP1631
008892
2
ENGLISH (Original instructions)
SPECIFICATIONS
Model HP1630 HP1631
Concrete 16 mm 16 mm
Steel 13 mm 13 mm Capacities
Wood 30 mm 30 mm
No load speed (min
-1) 0 - 3,200 0 - 3,200
Blows per minute 0 - 48,000 0 - 48,000
Overall length 296 mm 295 mm
Net weight 2.1 kg 2.0 kg
Safety class /II /II
• Due to our continuing program of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
END201-5
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
・ Read instruction manual.
・ DOUBLE INSULATION
・ Only for EU countries
Do not dispose of electric equipment
together with household waste material!
In observance of European Directive
2002/96/EC on waste electric and
electronic equipment and its
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an environmentally compatible recycling
facility.
ENE039-1
Intended use
The tool is intended for impact drilling in brick, concrete
and stone as well as for drilling without impact in wood,
metal, ceramic and plastic.
ENF002-1
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and can
only be operated on single-phase AC supply. They are
double-insulated in accordance with European Standard
and can, therefore, also be used from sockets without
earth wire.
ENG905-1
Noise
The typical A-weighted noise level determined according
to EN60745:
Sound pressure level (L
pA) : 97 dB (A)
Sound power level (L
WA) : 108 dB (A)
Uncertainty (K) : 3 dB (A)
Wear ear protection
ENG900-1
Vibration
The vibration total value (tri-axial vector sum) determined
according to EN60745:
Work mode: impact drilling into concrete
Vibration emission (ah,ID
) : 17.0 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: drilling into metal
Vibration emission (ah,D) : 2.5 m/s
2
Uncertainty (K) : 1.5 m/s2
ENG901-1
• The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.
• The declared vibration emission value may also be
used in a preliminary assessment of exposure.
WARNING:
• The vibration emission during actual use of the
power tool can differ from the declared emission
value depending on the ways in which the tool is
used.
• Be sure to identify safety measures to protect the
operator that are based on an estimation of
exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it
is running idle in addition to the trigger time).
3
ENH101-14
For European countries only
EC Declaration of Conformity
We Makita Corporation as the responsible
manufacturer declare that the following Makita
machine(s):
Designation of Machine:
Hammer Drill
Model No./ Type: HP1630,HP1631
are of series production and
Conforms to the following European Directives:
2006/42/EC
And are manufactured in accordance with the following
standards or standardised documents:
EN60745
The technical documentation is kept by our authorised
representative in Europe who is:
Makita International Europe Ltd.
Michigan Drive, Tongwell,
Milton Keynes, MK15 8JD, England
30.1.2009
000230
Tomoyasu Kato
Director
Makita Corporation
3-11-8, Sumiyoshi-cho,
Anjo, Aichi, JAPAN
GEA005-3
General Power Tool Safety
Warnings
WARNING Read all safety warnings and all
instructions.
Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and
instructions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Work area safety
1. Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
2. Do not operate power tools in explosive
atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools
create sparks which may ignite the dust or fumes.
3. Keep children and bystanders away while
operating a power tool. Distractions can cause
you to lose control.
Electrical safety
4. Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodified plugs and matching outlets will
reduce risk of electric shock.
5. Avoid body contact with earthed or grounded
surfaces such as pipes, radiators, ranges and
refrigerators. There is an increased risk of
electric shock if your body is earthed or grounded.
6. Do not expose power tools to rain or wet
conditions. Water entering a power tool will
increase the risk of electric shock.
7. Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or
moving parts. Damaged or entangled cords
increase the risk of electric shock.
8. When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of
a cord suitable for outdoor use reduces the risk of
electric shock.
9. If operating a power tool in a damp location is
unavoidable, use a residual current device
(RCD) protected supply. Use of an RCD reduces
the risk of electric shock.
10. Use of power supply via a RCD with a rated
residual current of 30mA or less is always
recommended.
Personal safety
11. Stay alert, watch what you are doing and use
common sense when operating a power tool.
Do not use a power tool while you are tired or
under the influence of drugs, alcohol or
medication. A moment of inattention while
operating power tools may result in serious
personal injury.
12. Use personal protective equipment. Always
wear eye protection. Protective equipment such
as dust mask, non-skid safety shoes, hard hat, or
hearing protection used for appropriate conditions
will reduce personal injuries.
13. Prevent unintentional starting. Ensure the
switch is in the off-position before connecting
to power source and/or battery pack, picking
up or carrying the tool. Carrying power tools with
your finger on the switch or energising power tools
that have the switch on invites accidents.
14. Remove any adjusting key or wrench before
turning the power tool on. A wrench or a key left
attached to a rotating part of the power tool may
result in personal injury.
15. Do not overreach. Keep proper footing and
balance at all times. This enables better control
of the power tool in unexpected situations.
Specyfikacje produktu
Marka: | Makita |
Kategoria: | Wiertarki udarowe |
Model: | HP1631K |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Makita HP1631K, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Wiertarki udarowe Makita
11 Października 2024
10 Października 2024
9 Sierpnia 2024
8 Sierpnia 2024
5 Lipca 2024
5 Lipca 2024
5 Lipca 2024
5 Lipca 2024
4 Lipca 2024
4 Lipca 2024
Instrukcje Wiertarki udarowe
- Wiertarki udarowe AEG
- Wiertarki udarowe Worx
- Wiertarki udarowe Milwaukee
- Wiertarki udarowe Bosch
- Wiertarki udarowe Parkside
- Wiertarki udarowe Black & Decker
- Wiertarki udarowe DeWalt
- Wiertarki udarowe RYOBI
- Wiertarki udarowe Meec Tools
- Wiertarki udarowe Ferm
- Wiertarki udarowe Hitachi
- Wiertarki udarowe HiKOKI
- Wiertarki udarowe Skil
- Wiertarki udarowe Stayer
- Wiertarki udarowe Tryton
- Wiertarki udarowe Ronix
- Wiertarki udarowe Luxor
- Wiertarki udarowe Bort
- Wiertarki udarowe Joka
- Wiertarki udarowe Valex
- Wiertarki udarowe Kress
- Wiertarki udarowe Pattfield
- Wiertarki udarowe Batavia
Najnowsze instrukcje dla Wiertarki udarowe
15 Października 2024
12 Października 2024
11 Października 2024
10 Października 2024
9 Października 2024
9 Sierpnia 2024
9 Sierpnia 2024
9 Sierpnia 2024
9 Sierpnia 2024
9 Sierpnia 2024