Technical manual
Mounting instructions
EM2010 DX
CHARACTERISTICS
The DirectXion lock can be mounted in all four mounting directions. Also, by flipping the lock,
all blocking directions can be achieved. The mounting dimensions are standard. The lock is
delivered with metric (M6) mounting screws. The PCB board in this lock is intended as an
OEM solution for customers who would like to control the lock via their own electronics. Once
voltage is supplied the lock will open for a 5 seconds and the boltwork can be moved into
OPEN position by pushing the bolt inside the lock case. After 5 seconds the board will cut
power to blocking element regardless if voltage is still supplied from external system. When
moving the boltwork into LOCKED position the DirectXion automatically locks. To open the
lock again the voltage has to be dropped and re-applied.
BOLTWORK REQUIREMENTS and MOUNTING INSTRUCTIONS
The maximum allowed cable/spindle-hole diameter is 12mm (if located under the lock body)
If the DirectXion lock is used in conjunction with another lock, the boltwork must be
constructed in a way that the DirectXion secures first.
In the LOCKED position the distance between the
DirectXion bolt and the boltwork part that is
moving the lock bolt should be approximately 1
mm.
Only use supplied screws to mount the lock.
Tighten the screws securely so the lock body is
attached firmly to the mounting surface.
DirectXion
M-LOCKS BV Tel: +31 (0)314 376 876
Vlijtstraat 40 ver. 1.2 2010 10 28 Fax: +31 (0)314 376 878
NL-7005 BN Doetinchem 2 of 2 www.m-locks.com
Connection to lock is via a RJ45 (female) connector on lock case. Cable (Art.nr. 390) has to
be ordered separately. Min voltage: 9V, Maximum voltage: 12V.
DirectXion
M-LOCKS BV Tel: +31 (0)314 376 876
Vlijtstraat 40 ver. 1.2 2010 10 28 Fax: +31 (0)314 376 878
NL-7005 BN Doetinchem 1 of 2 www.m-locks.com
Technical manual
Mounting instructions
EM3510 DX
CHARACTERISTICS
The DirectXion lock can be mounted in all four mounting directions. Also, by flipping the lock,
all blocking directions can be achieved. The mounting dimensions are standard. The lock is
delivered with metric (M6) mounting screws. The PCB board in this lock is intended as an
OEM solution for customers who would like to control the lock via their own electronics. Once
voltage is supplied the lock will open for a 5 seconds. The lock can be opened. After 5
seconds the board will cut power to blocking element regardless if voltage is still supplied
from external system. To open the lock again after closure the voltage has to be dropped and
re-applied.
BOLTWORK REQUIREMENTS and MOUNTING INSTRUCTIONS
The maximum allowed cable/spindle-hole diameter is 12mm (if located under the lock body)
If the DirectXion lock is used in conjunction with another lock, the boltwork must be
constructed in a way that the DirectXion secures first.
Only use supplied screws to mount the lock. Tighten the screws securely so the lock body is
attached firmly to the mounting surface.

Specyfikacje produktu

Marka: M-Locks
Kategoria: Sklepienie
Model: EM2010 DX

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z M-Locks EM2010 DX, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Sklepienie M-Locks

Instrukcje Sklepienie

Najnowsze instrukcje dla Sklepienie

Stamony

Stamony ST-KS-100N Instrukcja

15 Października 2024
Stamony

Stamony ST-KB-200 Instrukcja

15 Października 2024
Stamony

Stamony ST-KB-80P Instrukcja

15 Października 2024
Stamony

Stamony ST-KS-200N Instrukcja

15 Października 2024
Phoenix

Phoenix FS1512 Instrukcja

14 Października 2024
Phoenix

Phoenix CB0102K Instrukcja

14 Października 2024
Phoenix

Phoenix FS1911 Instrukcja

14 Października 2024
Phoenix

Phoenix GS8017 Instrukcja

14 Października 2024
SentrySafe

SentrySafe FPW082HTC Instrukcja

9 Października 2024
SentrySafe

SentrySafe FPW082KSB Instrukcja

9 Października 2024