Instrukcja obsługi Lowell SEQ-8

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Lowell SEQ-8 (4 stron) w kategorii Niet gecategoriseerd. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/4
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1603
Model SEQ-8 Rev. 08-12-21 | pg. 1/4
INTERNAL USE ONLY: PN 24369
Compact low voltage eight step sequencer model SEQ-8 is
designed to work with single or multiple external switches and
low voltage remote power controls (RPCs) to provide time-
delayed activation and deactivation of AC powered equipment
on site or at remote locations.
Note: This sequencer is for use with compatible components that feature classic
connections. It is not for use with devices that feature pass-through connections.
FEATURES:
Power Requirement: 100-240VAC 12W
Activation Trigger: Sequencing is initiated by a remote
external SPST switch or switches (order separately). Slide the
bar to select single or multiple switch mode.
For Single Switch Applications: Use an SPST switch with
MAINTAINED contact closure.
For Multiple Switch Applications: Use SPST switches with
MOMENTARY contact closure.
Eight (8) Step Delay:
Eight time-delayed closure circuits activate in sequential
order (1, 2, 3, 4, 5, 6, 7, 8) and deactivate in reverse order.
The delay between steps can be adjusted via an externally
accessible trimpot (0.5-10 seconds).
LEDs provide visual status of the sequence.
Includes auxiliary 24VDC output (300mA max.) for use with
remote indicators.
Compact Chassis: 10" x 3.28" x 1.69" steel chassis with
black powder epoxy finish and mounting holes.
Unit can be installed in a remote location or rack panel (2U).
Operational diagram printed on top of chassis aids system
set-up.
Country of Origin: Made in U.S.A. with global components
Power Supply: UL Listed power supply (100-240VAC input,
24VDC 500mA output) with 6 ft. cord and NEMA 1-15P plug.
Includes three adaptors for international use (Schuko CEE
7/16, BS1362, AS3112).
Installation: The sequencer is typically installed in a
convenient location, while remote power controls are placed
near equipment to be controlled—in another rack, room or
building.
Maximum distance between sequencer and remote power
controls: 22 gauge wire = 6,600 ft.; 18 gauge wire =
17,160 ft.
Maximum distance between sequencer and switch:
22 gauge wire = 100 ft.; 18 gauge wire = 200 ft.
System Capacity: Accepts up to 10 RPCs per step.
Connections: Order compatible remote power controls and
switches separately. (See last page.)
A&E Specications: The power sequencer shall be Lowell
model SEQ-8, which shall feature barrier strip terminals for
connection to a single external SPST switch with maintained
contact closure or multiple external SPST switches with
momentary closure. The sequencer shall connect to remote
power controls (RPCs) to activate equipment in up to eight
steps with an adjustable time delay between each step. It shall
activate the RPCs in sequential order and deactivate them in
reverse order. The sequencer shall feature a steel chassis
with mounting holes, black powder epoxy finish, and overall
dimensions of 10" x 3.28" x 1.69". shall be made in the It
USA with global components, and include a UL Listed power
supply with NEMA 1-15P plug and three adaptors (Schuko
CEE 7/16, BS1362, AS3112). External switch(es) and remote
power controls are required for sequencer use and shall be
ordered separately.
Low Voltage Sequencer (8 step): SEQ-8
Made in USA
INPUT for activation trigger (select single or multiple switches)
Chart for connections
Screwdriver-adjustable delay setting
Includes power supply
with NEMA 1-15P plug
and three adaptors
OUTPUT to connections
(up to 10 RPCs per circuit)
LEDs show sequencing status
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1603
Model SEQ-8 Rev. 08-12-21 | pg. 2/4
INTERNAL USE ONLY: PN 24369
Connect one Lowell RPS Series switch that features MAINTAINED closure
(remains on until turned off). The switch will feature one LED and use
three conductors.
Max. distance between SEQ-8 and switch: 22-gauge wire = 100 ft.; 18-gauge wire = 200 ft.
Select
SINGLE SWITCH.
Three (3)
conductors.
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Set sequencer to Single Switch. Connect equipment to Lowell RPC Series
remote power controls that feature classic connections (not pass-through),
and connect the RPC (switch and common terminals) to one of the steps
on the sequencer. Up to 10 RPCs can be connected in parallel on each
of the eight circuits.
Max. distance between SEQ-8 and RPCs: 22-gauge wire = 6,600 ft.; 18-gauge wire = 17,160 ft.
RPC connections
(step 8)
RPC connections
(step 7)
RPC connections
(step 6)
RPC connections
(step 5)
RPC connections
(step 4)
RPC connections
(step 3)
RPC connections
(step 2)
RPC connections
(step 1)
TYPICAL WIRING (one switch):
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1603
Model SEQ-8 Rev. 08-12-21 | pg. 3/4
INTERNAL USE ONLY: PN 24369
Connect multiple Lowell RPS Series switches
that feature MOMENTARY closure (release after
being pushed) and have one LED (which use
three conductors).
Max. distance between SEQ-8 and switch:
22-gauge wire = 100 ft.; 18-gauge wire = 200 ft.
Select
MULTIPLE SWITCHES
Three (3)
conductors.
Set sequencer to Multiple Switches. Connect equipment to Lowell RPC Series
remote power controls that feature classic connections (not pass-through),
and connect the RPC (switch and common terminals) to one of the steps
on the sequencer. Up to 10 RPCs can be connected in parallel on each
of the eight circuits.
Max. distance between SEQ-8 and RPCs:
22-gauge wire = 6,600 ft.; 18-gauge wire = 17,160 ft.
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
To additional RPCs
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
Switch
Com.
+24VDC Out
RPC connections
(step 8)
RPC connections
(step 7)
RPC connections
(step 6)
RPC connections
(step 5)
RPC connections
(step 4)
RPC connections
(step 3)
RPC connections
(step 2)
RPC connections
(step 1)
TYPICAL WIRING (multiple switches):

Specyfikacje produktu

Marka: Lowell
Kategoria: Niet gecategoriseerd
Model: SEQ-8

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Lowell SEQ-8, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niet gecategoriseerd Lowell

Lowell

Lowell ACS-2010-RPC-HW Instrukcja

7 Października 2024
Lowell

Lowell ACS-2020-6C-HW Instrukcja

7 Października 2024
Lowell

Lowell RPC-15-S Instrukcja

7 Października 2024
Lowell

Lowell RPC-3N1 Instrukcja

7 Października 2024
Lowell

Lowell SEQ-8 Instrukcja

7 Października 2024
Lowell

Lowell ACSP-1502-VTE Instrukcja

7 Października 2024
Lowell

Lowell RPC-20-SCD Instrukcja

7 Października 2024
Lowell

Lowell ACS-1512 Instrukcja

7 Października 2024
Lowell

Lowell ACS-1506 Instrukcja

7 Października 2024

Instrukcje Niet gecategoriseerd

Najnowsze instrukcje dla Niet gecategoriseerd

V-TAC

V-TAC VT-7808 Instrukcja

7 Października 2024
V-TAC

V-TAC VT-7804 Instrukcja

7 Października 2024
V-TAC

V-TAC VT-15545 Instrukcja

7 Października 2024
D-Jix

D-Jix M-Usik Instrukcja

7 Października 2024
Black Hydra

Black Hydra GAMMA-625C Instrukcja

7 Października 2024
Palmer

Palmer PB 10 Instrukcja

7 Października 2024
Palmer

Palmer ABO Instrukcja

7 Października 2024
CRUX

CRUX SOOGM-16K Instrukcja

7 Października 2024
Sitecom

Sitecom CA-1001 Instrukcja

7 Października 2024