Instrukcja obsługi Lowell ACS-2012


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Lowell ACS-2012 (3 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/3
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1728
Model ACS-2012 Rev. 05-05-21 | pg. 1/3
INTERNAL USE ONLY: PN 24222
Power strip features a total of twelve 15A and 20A NEMA receptacles in a low
prole chassis. It includes surge suppression with LED status indicator.
FEATURES:
Power Rating: 120VAC, 60Hz, 20A
Chassis: 32" x 1.625" x 1.375" steel chassis with black powder epoxy
finish
Termination: 12-ft. attached (non-removable) power cord with NEMA 5-20P
molded plug
Receptacles: (12 total)
Eight (8) single NEMA 5-15R receptacles
Four (4) single NEMA 5-20R receptacles
Surge Suppession: Common mode transient voltage surge suppression
(UL 1449-3 Listed) with 20A circuit breaker:
LED indicator: Llit when protection is active
Maximum surge current: 6500A (L-G, L-N, N-G)
Maximum surge voltage: 6000V
Suppressed voltage rating: 400V
Energy dissipation: 450 Joules (8 x 20us waveform)
Lines protected: L-G, L-N, N-G
Response time: Less than one (1) nanosecond
Noise ltering: EMI / RFI
Mounting Hardware: Clips and screws are provided for vertical installation
in a rack that has adjustable or xed rails. Includes cable ties to secure
power supplies when the strip is mounted vertically.
Certication: UL Listed
Origin: China
A&E Specications: The UL Listed power strip shall be Lowell model ACS-
2012, whhich shall have a power rating of 120VAC, 60Hz, 20A and include a
circuit breaker. It shall feature twelve NEMA receptacles (eight 15A and four
20A). It shall include common mode transient voltage surge suppression
with an LED indicator that is lit when protection is active. The power strip
shall have a suppressed voltage rating of 400V with maximum surge voltage
of 6000V and maximum surge current of 6500A. It shall be terminated with
an attached 12-foot cord and molded plug. The power strip shall include a
mounting clip, screw, and cable ties.
AC Power Strip w/Surge Suppression: ACS-2012
Attached power cord
with plug
Receptacles
are spaced to
accept some
power supplies
20A circuit breaker
LED indicator
is lit when
protection is
active
Mounting hardware
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1728
Model ACS-2012 Rev. 05-05-21 | pg. 2/3
INTERNAL USE ONLY: PN 24222
1. Install mounting clip to
Z-bracket using hardware
provided.
2. Align power strip with
mounting clips and snap
into place.
Z-bracket in rear
1. Install mounting clip to rack
rail mounting channel using
hardware provided.
2. Align power strip with mounting
clips and snap into place.
Rack rail mounting channel
Rack with adjustable rails Rack with xed rails and Z-bracket
INSTALLATION: Use the mounting clip and hardware to mount to a rack.
RECEPTACLE LAYOUT: Receptacles are NEMA 5-15R (15A) except the four noted as NEMA 5-20R.
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1728
Model ACS-2012 Rev. 05-05-21 | pg. 3/3
INTERNAL USE ONLY: PN 24222
ACS Series Power Strips (overview)
Power NEMA Chassis Chassis On/Off Surge Remote Mounting Country
Model No. Rating Receptacles Circuits Length Profile Termination Switch Suppression Power Control Aids of Origin
ACS-1505-SW 15A 5 (15A) 1 12" Standard 6' Det. cord Yes --- --- Brackets U.S.
ACS-1505-SW-SD 15A 5 (15A) 1 12" Standard 6' Det. cord Yes 2-stage --- Brackets U.S.
ACS-1506 15A 6 (15A) 1 20" Low 6' Fixed cord --- 1-stage --- Clips China
ACS-1506-WW 15A 6 (15A) 1 12" Low 6' Fixed cord --- --- --- Screws U.S.
ACS-1507 15A 7 (15A) 1 12" Low 6' Det. cord --- --- --- Screws U.S.
ACS-1512 15A 12 (15A) 1 32" Low 12' Fixed cord --- 1-stage --- Clips China
ACS-1524 15A 24 (15A) 1 60" Low 12' Fixed cord --- 1-stage --- Clips China
ACS-1524-2C 15A 24 (15A) 2 70" Low Pigtail leads --- --- --- Clips China
ACS-2012 20A 8 (15A) + 4 (20A) 1 32" Low 12' Fixed cord --- 1-stage --- Clips China
ACS-2024 20A 16 (15A) + 8 (20A) 1 70" Low 12' Fixed cord --- 1-stage --- Clips China
ACS-2014-HW 20A 14 (20A) 1 30" Standard 6' Conduit --- --- --- Brackets U.S.
ACS-2014-2C-HW 20A 8 (15A) + 6 (20A) 2 30" Standard 6' Conduit --- --- --- Brackets U.S.
ACS-2020-6C-HW 20A 20 (20A) 6 60" Standard 6' Conduit --- --- --- Brackets U.S.
ACS-2020-IG-6C-HW 20A 20 (I.G. 20A) 6 60" Standard 6' Conduit --- --- --- Brackets U.S.
ACS-2020-IG-10C-HW 20A 20 (I.G. 20A) 10 60" Standard 6' Conduit --- --- --- Brackets U.S.
ACS-2024-2C 20A 24 (20A) 2 70" Low Pigtail leads --- --- --- Clips China
ACS-1510-RPC 15A 10 (15A) 1 30" Standard 6' Det. cord --- --- Yes Brackets U.S.
ACS-2010-RPC-HW 20A 10 (20A) 1 30" Standard 6' Conduit --- --- Yes Brackets U.S.
ACS-2018-5C-RPC-HW 20A 18 (20A) 5 60" Standard 6' Conduit --- --- Yes Brackets U.S.
ACS-2018-5C-RPCP-HW 20A 18 (20A) 5 60" Standard 6' Conduit --- 1-stage Yes (P) Brackets U.S.
Chassis Profile = Standard profile (2" x 2"), Low profile (1.625" x 1.375")
Termination = Det. cord (detachable cord), Fixed cord (cord is attached–cannot be removed), Conduit (non-metallic flexible whip w/pigtail leads), Pigtail leads (leads at ends of chassis—no whip)
Switch = Yes (On/off rocker switch)
Surge Suppression = 1-stage (basic surge protection), 2-stage (surge protection with backup)
Remote Power Control = Some receptacles are controlled by a remote switch or sequencer (ordered separately); (P) indicates compatibility with Lowell P-Series pass-through sequencers.
Mounting Aids = Brackets (multi-hole brackets with hardware), Clips (clips and screws with wire tires), or Screws (power strips can mount to rear of US or USV Series shelves).
This
spec


Specyfikacje produktu

Marka: Lowell
Kategoria: Niesklasyfikowane
Model: ACS-2012