Instrukcja obsługi Littelfuse SE-105


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Littelfuse SE-105 (20 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/20
3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/relayscontrols
SE-105 MANUAL
GROUND-FAULT GROUND-CHECK MONITOR
REVISION 13-D-050315
F 1
F 2
R E S E T
R E S E T
R E S E T
R E S E TR E S E TG R O U N D
F A U L T
G R O U N D
G R O U N D
G R O U N D
G R O U N D
F A U L T
F A U L T
F A U L T
F A U L T
G F T R I P
T I M E ( s )
G F
G F
G F
G F T R I P
T R I P
T R I P
T R I P
T I M E
T I M E
T I M E
T I M E ( s )
( s )
( s )
( s )
P O W E R
P O W E R
P O W E R
P O W E RP O W E R
G R O U N D
C H E C K
G R O U N D
G R O U N D
G R O U N D
G R O U N D
C H E C K
C H E C K
C H E C K
C H E C K
C T 1
C T 1
C T 1
C T 1C T 1
C T 2
C T 2
C T 2
C T 2C T 2
A
A
A
AA B
B
B
BB
G I
G I
G I
G IG I
C I
C I
C I
C IC I
S W
S W
S W
S WS W
L 1
L 1
L 1
L 1L 1
G C
G C
G C
G CG C
L 2
L 2
L 2
L 2L 2
G
G
G
GG
M O D E
M O D E
M O D E
M O D EM O D E
G F
G F
G F
G FG F
0 . 1
0 . 1
0 . 1
0 . 10 . 1 2 . 0
2 . 0
2 . 0
2 . 02 . 0
1 . 0
1 . 0
1 . 0
1 . 01 . 0
4 . 0
4 . 0
4 . 0
4 . 04 . 0 A
A
A
AA
2 . 0
2 . 0
2 . 0
2 . 02 . 0 A
A
A
AA
0 . 5
0 . 5
0 . 5
0 . 50 . 5 A
A
A
AA
S H
S H
S H
S HS H
U V
U V
U V
U VU V
G F - G C M O N ITOR
G F - G C
G F - G C
G F - G C
G F - G C M O N I T O R
M O N I T O R
M O N I T O R
M O N I T O R
S E - 1 0 5
S E - 1 0 5
S E - 1 0 5
S E - 1 0 5S E - 1 0 5
E N H A N C E D
F I L T E R I N G
E N H A N C E D
E N H A N C E D
E N H A N C E D
E N H A N C E D
F I L T E R I N G
F I L T E R I N G
F I L T E R I N G
F I L T E R I N G
Copyright 2015 by Littelfuse Startco
All rights reserved.
Document Number: PM-1300-EN
Printed in Canada.
Page i
SE-105 Ground-Fault Ground-Check Monitor Rev. 13-D-050315
This page intentionally left blank.
Page ii
SE-105 Ground-Fault Ground-Check Monitor Rev. 13-D-050315
T ABLE OF CONTENTS
S PECTION AGE
1 General ................................................................. 1
2 Operation ............................................................. 1
2.1 Settings .................................................................. 1
2.1.1 GF Trip Time ............................................. 1
2.1.2 GF .............................................................. 1
2.1.3 Mode .......................................................... 1
2.2 Indication and Reset .............................................. 1
2.3 Fusing .................................................................... 1
3 Installation ........................................................... 2
3.1 SE-105 .................................................................. 2
3.2 Ground-Fault CT ................................................... 4
3.3 Ground-Check Termination .................................. 5
3.4 Remote Operation ................................................. 6
3.5 Parallel-Path Isolation ........................................... 6
3.6 Ground-Fault Testing ............................................ 6
4 Compatibility ....................................................... 6
5 Technical Specifications ................................... 12
5.1 SE-105 ................................................................ 12
5.2 Current Sensors ................................................... 13
5.3 Termination Assemblies ..................................... 13
6 Ordering Information ....................................... 13
7 Warranty ........................................................... 14
8 Ground-Fault Performance Test ..................... 15
Appendix A SE-105 Revision History ......................... 16
L IST OF FIGURES
F PIGURE AGE
1 Typical Application .............................................. 3
2 SE-105 Outline and Mounting Details .................. 4
3 CT200 and CT200L Current Transformers .......... 5
4 Zener-Diode Termination Devices ........................ 6
5 SE-TA6 Termination Assembly ............................ 7
6 SE-TA6ASF-WL Small-Format Termination
Assembly with Wire Leads ................................... 7
7 RK-102 Remote Indication and Reset Kit ............ 8
8 RK-105 Remote Indication-and-Reset Assembly . 8
9 RK-105I Remote Indication Assembly ................. 9
10 RK-13 Relay Interface Module ............................. 9
11 PPI-600V Parallel-Path Isolator .......................... 10
12 PPI-600V Typical Installation ............................ 11
13 Ground-Fault-Test Circuits ................................. 15
L IST OF TABLES
TABLE PAGE
1 Terminal Designations .......................................... 6
2 Ground-Fault-Test Record .................................. 15
D ISCLAIMER
Specifications are subject to change without notice.
Littelfuse Startco is not liable for contingent or
consequential damages, or for expenses sustained as a
result of incorrect application, incorrect adjustment, or a
malfunction.


Specyfikacje produktu

Marka: Littelfuse
Kategoria: Niesklasyfikowane
Model: SE-105

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Littelfuse SE-105, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Littelfuse

Littelfuse

Littelfuse SE-105 Instrukcja

25 Września 2024
Littelfuse

Littelfuse SE-701 Instrukcja

25 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024