IMPORTANT:
Prior to installation, record Model, Serial Number, and
Code Number from pump nameplate for future reference.
MODEL ________________________
SERIAL ______________________
CODE ______________________
INSTALLATION
DATE _____________________ __
CSP-237 1/3HP 115V 60Hz
CSP- 7 1/3HP 115V 60Hz 25
CSP-457 1/2HP 115V 60Hz
7000 Apple Tree Avenue
Bergen, NY 14416
Phone: (800) 543-2550
Fax: (585) 494-1839
www.libertypumps.com
Contents
1.) General Information and Safety
Guidelines
2.) Installation
3.) Maintenance and Troubleshooting
Installation Manual 4353 0C00
Model CSP-237, CSP-257, and CSP-457 Crawl Space Pump
©Copyright 2011 Liberty Pumps Inc. All rights reserved -2-
Before installation, read the following instructions carefully. Each Liberty pump is individually factory tested to insure proper
performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.
Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
The electrical connections and wiring for a pump installation should only be made by qualified personnel.
This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
Do not bypass grounding wires or remove ground prong from attachment plugs.
Do not use an extension cord.
This pump requires separate, properly fused and grounded branch circuit. Make sure the power source is properly sized for the a
voltage and amperage requirements of the pump, as noted on the nameplate.
The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor level to minimize
possible hazards from flood conditions.
The installation must be in accordance with the National Electric Code and Plumbing Codes as well as all applicable local codes
and ordinances.
Fig. 1 – Typical Residential Installation
This is a recommended installation only.
1. General Information and Safety Guidelines
2. Installation
Figure 1
©Copyright 2011 Liberty Pumps Inc. All rights reserved -3-
Application: The CSP- , CSP-257, and CSP-457 crawl space pumps are designed for use a crawl space or where pooling water 237 in
is occurring. Allowing the water in the pump or discharge line to freeze may cause damage to the pump. In colder regions, the pump
should only be installed indoors or deep enough to be below the frost line.
A. For in ground installation a hole should excavated as small as possible, leaving at least 8” of diametrical clearance. BACKFILL:
Course gravel is recommended for backfill.
B. The CSP- , CSP-257, and CSP-457 include a perforated basin for gathering water. Additional inlets may be added with INLET: 237
a hole saw for allowing drain lines or weep tiles.
C. When attaching the discharge, place the pump in the basin being careful to keep float from any obstruction or from DISCHARGE:
hitting the tank wall. The CSP- , CSP-257, and CSP-457 include a DHK-24 discharge hose kit. A 1-1/2” X 1-1/4” hose adapter 237
will thread into the pump discharge. The 24’ flexible hose will fit over the barbed fitting of the adapter and should be tightened
down with a hose clamp. The hose will fit through the grommet in the basin cover and can be cut to the required length. Exit the
discharge of water in an area that will drain away from the building and foundation.
D. The CSP- , CSP- and CSP-457 include a threaded check valve for use with the discharge hose. If the CHECK VALVE: 237 257,
pump is short cycling, then a check valve may be required. This would prevent water from draining back through the discharge
hose into the basin. When using a check valve, the discharge line must be protected from freezing by running the discharge deep
enough below ground level to be beneath the frost line. See figure 1.
E. The pump power cord is equipped with a grounding conductor and grounding-type 3-prong plug. It should be POWER CORD:
connected to a separately fused, grounded, 3-wire grounding-type receptacle of 15-amp capacity with the proper . Make sure 115V
all electrical wiring and connections are in accordance with the National Electric Code and all applicable local codes.
Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
DO NOT remove the plug or ground prong.
DO NOT use an extension cord.

Specyfikacje produktu

Marka: Liberty Pumps
Kategoria: Pomp
Model: CSP-257

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Liberty Pumps CSP-257, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Pomp Liberty Pumps

Liberty Pumps

Liberty Pumps 250 Instrukcja

9 Października 2024
Liberty Pumps

Liberty Pumps 457 Instrukcja

9 Października 2024
Liberty Pumps

Liberty Pumps 230 Instrukcja

9 Października 2024
Liberty Pumps

Liberty Pumps CSP-257 Instrukcja

9 Października 2024
Liberty Pumps

Liberty Pumps LE51A Instrukcja

21 Września 2024

Instrukcje Pomp

Najnowsze instrukcje dla Pomp

T.I.P.

T.I.P. Maxima 250 SX Instrukcja

9 Października 2024
Danfoss

Danfoss GearMe Instrukcja

9 Października 2024
Comet

Comet BPV 500 Instrukcja

9 Października 2024
Comet

Comet P 40/20 Instrukcja

9 Października 2024
Comet

Comet C 610 H Instrukcja

9 Października 2024
Anova

Anova P101 Instrukcja

8 Października 2024
Comet

Comet Ocean 12V Instrukcja

8 Października 2024
Comet

Comet Geo Inline Plus Instrukcja

8 Października 2024
Comet

Comet VIP Plus Inline Instrukcja

8 Października 2024