Instrukcja obsługi LG N12AWR
LG
Klimatyzatory
N12AWR
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla LG N12AWR (21 stron) w kategorii Klimatyzatory. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/21
LG
Room
Air Conditioner
OWNER'S MANUAL
LG
Visit us at http://www.lgservice.com
IMPORTANT
• Please read this owner's manual carefully and thoroughly
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
Dear Owner
Thank you for installing LG air conditioner.
Your best choice guarantees you a great
performance and service to make your life
comfortable & pleasant.
ENGLISH DANSKSVENSKA SUOMINORSK
2 Room Air Conditioner
Room Air Conditioner Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
• Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by
authorized personnel only using only genuine
replacement parts.
A. Safety Precautions ..............................3
B. Electrical Safety...................................6
Temporary Use of an Adapter ...............6
Temporary Use of an Extension Cord ...6
Symbols used in this Manual.................6
C. Product Introduction...........................7
Indoor Units ...........................................7
Operation Indication Lamps ..................8
Outdoor Unit ..........................................8
D. Operating Instructions........................9
How to insert the Batteries ....................9
Wireless Remote Controller
Maintenance..........................................9
Operating Method..................................9
Wireless Remote Controller.................10
Operation Mode...................................11
Healthy Dehumidification Operation....12
Auto Operation
(Cooling Only Model)...........................12
Auto Changeover Operation
(Heat Pump Model) .............................12
Jet Cool/Heat Operation......................13
NEO PLASMA Purification Operation
(Optional).............................................13
Auto Clean (Optional)..........................13
Energy-Saving Cooling Mode
(Optional).............................................14
Forced operation .................................14
Sleep Mode .........................................15
Setting the Current Time .....................15
Timer Setting .......................................15
Vertical / Horizontal Airflow Direction
Control (Optional) ................................16
Air Circulation Mode ............................16
Auto Restart Function..........................16
E. Maintenance and Service..................17
Indoor Unit...........................................17
Outdoor Unit ........................................19
Operation Tips!....................................19
Self-Diagnosis Function ......................19
Troubleshooting Tips!
Save time and money!.........................20
Call the service immediately in the
following situations ..............................20
Owner's Manual 3
Safety Precautions
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by
the following indications.
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
Always use a power plug and socket with
a ground terminal.
• There is a risk of electric shock.
Do not use a defective or underrated
circuit breaker. Use the correctly rated
breaker and fuse.
• There is risk of fire or electric shock .
Do not use a multi consent. Always use
this appliance on a dedicated cicuit and
breaker.
• Otherwise it can cause electric shock or fire.
For electrical work, contact the dealer, seller,
a qualified electrician, or an Authorized
Service Center. Do not disassemble or repair
the product by yourself.
• There is risk of fire or electric shock.
Always ground the product as per the
wiring diagram. Do not connect the
ground wire to gas or water pipes
lightening rod or telephone ground wire.
• There is risk of fire or electric shock.
Install the panel and the cover of control
box securely.
• There is risk of fire or electric shock due to
dust , water etc.
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
Do not modify or extend the power cable.
If the power cable or cord has scrathes or
skin peeled off or deteriorated then it
must be replaced.
• There is risk of fire or electric shock.
For installation, removal or reinstall ,
always contact the dealer or an
Authorized Service Center.
• There is risk of fire, electric shock, explosion,
or injury.
Do not install the product on a defective
installation stand. Be sure that the
installation area does not deteriorate with
age.
• It may cause product to fall.
Never install the outdoor unit on a
moving base or a place from where it
can fall down.
• The falling outdoor unit can cause damage or
injury or even death of a person.
When the product is soaked (flooded or
submerged) in water , contact an
Authorized Service Center for repair
before using it again.
• There is risk of fire or eletric shock.
In outdoor unit the step-up capacitor
supplies high voltage electricity to the
electrical components. Be sure to
discharge the capacitor completely
before conducting the repair work.
• An charged capacitor can cause electrical
shock.
When installing the unit, use the
installation kit provided with the product.
• Otherwise the unit may fall and cause severe
injury.
Be sure to use only those parts which
are listed in the svc parts list. Never
attempt to modify the equipment.
• The use of inappropriate parts can cause an
electrical shock, excessive heat generation or
fire.
Specyfikacje produktu
Marka: | LG |
Kategoria: | Klimatyzatory |
Model: | N12AWR |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z LG N12AWR, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Klimatyzatory LG
8 Października 2024
6 Października 2024
9 Sierpnia 2024
8 Sierpnia 2024
6 Lipca 2024
6 Lipca 2024
5 Lipca 2024
5 Lipca 2024
5 Lipca 2024
4 Lipca 2024
Instrukcje Klimatyzatory
- Klimatyzatory Bauknecht
- Klimatyzatory Samsung
- Klimatyzatory Electrolux
- Klimatyzatory Beko
- Klimatyzatory Gorenje
- Klimatyzatory Sharp
- Klimatyzatory Whirlpool
- Klimatyzatory Fujitsu
- Klimatyzatory Midea
- Klimatyzatory Hisense
- Klimatyzatory Infiniton
- Klimatyzatory Panasonic
- Klimatyzatory Nedis
- Klimatyzatory Adler
- Klimatyzatory Toshiba
- Klimatyzatory GE
- Klimatyzatory Siemens
- Klimatyzatory Danby
- Klimatyzatory Haier
- Klimatyzatory Master
- Klimatyzatory ECG
- Klimatyzatory Amana
- Klimatyzatory Daikin
- Klimatyzatory Alaska
- Klimatyzatory Trotec
- Klimatyzatory Klarstein
- Klimatyzatory Vaillant
- Klimatyzatory Camry
- Klimatyzatory Qlima
- Klimatyzatory TriStar
- Klimatyzatory Mitsubishi
- Klimatyzatory Gree
- Klimatyzatory Sanyo
- Klimatyzatory Telefunken
- Klimatyzatory Inventum
- Klimatyzatory SVAN
- Klimatyzatory Comfee
- Klimatyzatory Orima
- Klimatyzatory Hitachi
- Klimatyzatory SereneLife
- Klimatyzatory Frigidaire
- Klimatyzatory Whynter
- Klimatyzatory Kelvinator
- Klimatyzatory Fuave
- Klimatyzatory Suntec
- Klimatyzatory Daewoo
- Klimatyzatory Zibro
- Klimatyzatory Becken
- Klimatyzatory Eurom
- Klimatyzatory Coolix
- Klimatyzatory Haverland
- Klimatyzatory Rasonic
- Klimatyzatory Mabe
- Klimatyzatory Alhafidh
- Klimatyzatory Heinner
- Klimatyzatory Campomatic
- Klimatyzatory White Knight
- Klimatyzatory Inventor
- Klimatyzatory Admiral
- Klimatyzatory Elba
- Klimatyzatory Royal Sovereign
- Klimatyzatory AlpicAir
- Klimatyzatory Tatung
- Klimatyzatory Daitsu
- Klimatyzatory Olimpia Splendid
- Klimatyzatory Lloyd
- Klimatyzatory Saunier Duval
- Klimatyzatory National
- Klimatyzatory Godrej
- Klimatyzatory Maiko
- Klimatyzatory Diamant
- Klimatyzatory Western
- Klimatyzatory Equation
- Klimatyzatory Airmaster
- Klimatyzatory Taurus-Alpatec
- Klimatyzatory Maxicool
- Klimatyzatory Tarrington House
- Klimatyzatory Evapolar
- Klimatyzatory Commercial Cool
Najnowsze instrukcje dla Klimatyzatory
15 Października 2024
15 Października 2024
15 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
13 Października 2024
13 Października 2024
13 Października 2024