Instrukcja obsługi Levita T110-W
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Levita T110-W (8 stron) w kategorii termometr. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/8

1
TOPCOM TWINTALKER 3000
LEVITA T110-W - Digital Clinical Thermometer - User Guide
1 Introduction
Congratulations on the purchase of the Digital Thermometer T110-W. We hope you will
enjoy using the thermometer and the benefits it offers.
2 Safety notes
3 Description
1. Sensor
2. Flexible tip
3. LCD Display
4. ON - OFF button
5. Battery cover
4 Battery installation
If the battery low indication or is displayed, the battery needs to be replaced.
• Turn the themometer upside down.
• Remove the battery cover (5) from the thermometer.
• Pull gently the electronic part out of the unit until the battery is completely visible
(max 1cm from the unit).
• Use a pointed object to remove the old battery.
• Place a new 1,5V DC battery (SR41, LR41, 392 or 192) with the positive pole (+)
side up and the negative pole (-) facing down in battery compartment.
• Re-install the electronic part and put the battery cover back on the thermometer.
5 Measurement
5.1 Fever facts
Although the generally accepted "normal" temperature reading is 37.0°C, temperature
reading can vary from 36°C to 37.3°C and still may be considered as "normal".
Your body temperature can be influenced by your activities such as exercise, smoking,
eating and drinking.
Even time of day may influence your body temperature. For example, your temperature
is lower in the morning than in the afternoon.
Other variations may be due to the location of the temperature reading.
While the oral temperature follows the guidelines previously described, a rectal
temperature is generally 0.5°C higher. Conversely, an auxiliary (under the arm)
temperature will be 0.5°C lower.
A rectal temperature is considered as your real or "core" body temperature, while the
underarm method will often give an inaccurate reading and should not be used if a
precise measurement is required.
WARNING
- Read through the instruction manual before using the thermometer, as proper
technique is critical for taking accurate temperatures.
- Keep this user guide for further reference
- This thermometer is intended for household use only. The use of this thermometer
is not intended as a substitute for physician’s consultation.
- Do not allow the device to come in contact with hot water.
- The thermometer has a flexible tip. Do not bend it for more than 45°.
- Do not expose to direct sunlight, high temperature, moisture or dirt.
- Do not drop the thermometer. It is neither shock-proof nor impact-resistant.
- Do not open the device (except the battery compartment)
- Do not immerse the waterproof thermometer in liquid longer than 10 minutes
DANGER
- The thermometer contains small parts (battery, battery cover) which can be
swallowed by small children. For this reason, do not leave the thermometer
unattended in hands of children.
- When the temperature is higher than 38°, means that the patient may have
fever. Contact your doctor. Persistent fever, in particular children, has to be
treated by a doctor. Get in touch with a doctor immediately.
1 2 34 5
HL_T110-W_UK-ES.book Page 1 Wednesday, June 3, 2009 1:56 PM

2V 1.0 - MD8100290
ENGLISH
LEVITA T110-W - Digital Clinical Thermometer - User Guide
5.2 Oral use
• Place the probe tip under the tongue as near as possible to
the heat pocket. The diagram also shows the temperature
variables by not placing the tip in the heat pocket area.
• Close the mouth.
• Press the ON/OFF button (4) briefly. After all segments
have been displayed, ‘L°C’ flashes on the display.
• The thermometer starts measurement.
• When the temperature stabilizes at peak temperature, 4
beeps are audible and the result is displayed.
• Press the ON/OFF button (4) to turn the unit off or the unit will automatically shut
off after approximately ten minutes.
5.3 Axillary use (under arm)
• Wipe the underarm with a dry towel.
• Place the probe tip under the arm so the tip is touching the skin with the
thermometer perpendicular to the body.
• Position the arm across the chest so the probe tip is well covered by the arm. This
also insures the probe is not affected by the room's air.
• Press the ON/OFF button (4) briefly. After all segments have been displayed,
‘L°C’ flashes on the display.
• The thermometer starts measurement.
• When the temperature stabilizes at peak temperature, 4 beeps are audible and
the result is displayed.
• Press the ON/OFF button (4) to turn the unit off or the unit will automatically shut
off after approximately ten minutes.
IMPORTANT NOTE
- It is important to clean your Thermometer before the first time of use and after
each application, otherwise the result may be incorrect.
- After a shower or exercise, the body temperature will rise. Take a rest before
taking temperature.
- If the ambient temperature is more than 35°C, dip the thermometer tip in cold
water for approximately 5 to 10 seconds prior to measuring the temperature.
- Stay with your child during measurement to assure proper use.
Average measurement time 17 +/- 2 seconds
Average nomal temperature 37,0°C
IMPORTANT NOTE
- Drinking hot or cold fluids, exercising, smoking or performing other activities may
raise or lower your temperature. Therefore, it is important to relax for
approximately 5 minutes with your mouth closed prior to taking a reading.
- Place the probe under the tongue and close your mouth until the temperature
stabilizes.
- Keep the thermometer in one place without shifting it in the mouth.
Average measurement time 26 +/- 2 seconds
Average nomal temperature 36,5°C
HL_T110-W_UK-ES.book Page 2 Wednesday, June 3, 2009 1:56 PM

3
TOPCOM TWINTALKER 3000
LEVITA T110-W - Digital Clinical Thermometer - User Guide
5.4 Rectal use
• Apply a water-soluble lubricant to the tip.
• Gently insert the tip of the probe maximum 1 cm into the rectum.
• Press the ON/OFF button (4) briefly. After all segments have been displayed,
‘L°C’ flashes on the display.
• The thermometer starts measurement.
• When the temperature stabilizes at peak temperature, 4 beeps are audible and
the result is displayed.
• Press the ON/OFF button (4) to turn the unit off or the unit will automatically shut
off after approximately ten minutes.
6 Memory function
The thermometer stores the last result.
• Press and hold the ON/OFF button (4). The last result will be displayed until the
button is released.
7 Specifications
8 Cleaning and storing
• Clean your Digital Thermometer by wiping it with soap and water or 70%
isopropyl Alcohol.
• This waterproof thermometers can be immersed in liquid or lukewarm water
(maximum 40°C) for through cleaning and disinfection.
• Store the unit in the supplied protection case in a dry place.
Average measurement time 17 +/- 2 seconds
Average nomal temperature 37°C
IMPORTANT NOTE
- It is suggested that a rectal used thermometer is separated from a axillary or oral
used thermometer because of hygienic reason.
- Rectal temperatures are an appropriate and reliable method for infants and small
children. Otherwise, it is advised to be used when it is impossible or impractical to
take an oral or auxiliary temperature.
- It is suggested that a rectal used thermometer is separated from a axillary or oral
used thermometer because of hygienic reason.
WARNING
- Do not use petroleum jelly like Vaseline for easier insertion, as this may cause
irritation.
Measuring range
Accuracy
Resolution
Working conditions
Storage conditions
Battery
Battery Life
Power consumption
Dimension
Weight
Classification
32,0 ~ 42°C
+/- 0,1°C (35,5 °C ~ 42°C)
0,1°C
Temp 10 ~ 35°C
Hum 60 +/-20% RH
Temp -25 ~ 55°C
Hum 60 +/-10% RH
1,5V DC Alkaline manganese
replacement types : SR41, LR41, 392 or 192
Approx, 100 hours for continuous operation
0,15mW
132 x 21,5 x 14 mm
Approx. 14 grams with battery inside
Type B equipment
IMPORTANT NOTE
- Do not immerse the waterproof thermometers in liquid for longer than 30 minutes.
- Do not clean with thinner, petrol or benzene. Only clean with water or disinfectant.
- The thermometer is calibrated and does not need re-calibration if used according
to the instructions.
HL_T110-W_UK-ES.book Page 3 Wednesday, June 3, 2009 1:56 PM
Specyfikacje produktu
Marka: | Levita |
Kategoria: | termometr |
Model: | T110-W |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Levita T110-W, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje termometr Levita

3 Lutego 2025

27 Września 2024
Instrukcje termometr
- termometr PeakTech
- termometr AEG
- termometr Motorola
- termometr Beurer
- termometr Sanitas
- termometr Joy-It
- termometr Braun
- termometr Tefal
- termometr Voltcraft
- termometr Milwaukee
- termometr Philips
- termometr SilverCrest
- termometr Nokia
- termometr Withings
- termometr Nedis
- termometr Stanley
- termometr Rossmax
- termometr Marquant
- termometr Quigg
- termometr Orbegozo
- termometr Citizen
- termometr Homedics
- termometr Silverline
- termometr Testo
- termometr TFA
- termometr Chauvin Arnoux
- termometr Scala
- termometr Uni-T
- termometr Medisana
- termometr Cuisinart
- termometr Auriol
- termometr IFM
- termometr Emerio
- termometr Owon
- termometr Melissa
- termometr Beper
- termometr Techno Line
- termometr TrueLife
- termometr Emos
- termometr Perel
- termometr Trotec
- termometr Omron
- termometr Thomson
- termometr La Crosse Technology
- termometr Velleman
- termometr Aponorm
- termometr Safety 1st
- termometr Arendo
- termometr Pyle
- termometr Waeco
- termometr Speco Technologies
- termometr Weber
- termometr Microlife
- termometr Fluke
- termometr Greisinger
- termometr TriStar
- termometr Miniland
- termometr Bartscher
- termometr BeSafe
- termometr Kerbl
- termometr Westfalia
- termometr Clatronic
- termometr Telefunken
- termometr Oregon Scientific
- termometr Inventum
- termometr TurboTronic
- termometr Innoliving
- termometr Bresser
- termometr Elro
- termometr Olympia
- termometr Hama
- termometr Taylor
- termometr Duronic
- termometr Omega
- termometr Medel
- termometr Optex
- termometr Boso
- termometr Terraillon
- termometr Esperanza
- termometr ZKTeco
- termometr Extech
- termometr Elta
- termometr Denver
- termometr Testboy
- termometr Geratherm
- termometr Respekta
- termometr SereneLife
- termometr Kyoritsu
- termometr Vemer
- termometr Klein Tools
- termometr Lanaform
- termometr Inkbird
- termometr Leifheit
- termometr Eurochron
- termometr Topcom
- termometr Sencor
- termometr Powerfix
- termometr Alecto
- termometr ADE
- termometr Etekcity
- termometr ProfiCare
- termometr Reer
- termometr Comelec
- termometr Cotech
- termometr Beha-Amprobe
- termometr Clas Ohlson
- termometr Laserliner
- termometr Ecomed
- termometr Salter
- termometr TensCare
- termometr Zeiss
- termometr Veroval
- termometr Fysic
- termometr AnD
- termometr Amprobe
- termometr ATN
- termometr Kruidvat
- termometr Easypix
- termometr Cresta
- termometr GlobalTronics
- termometr Flir
- termometr AcuRite
- termometr Summer
- termometr Technoline
- termometr Vicks
- termometr Welch Allyn
- termometr BabyOno
- termometr Laica
- termometr Mabis
- termometr Turbotech
- termometr Luvion
- termometr Irox
- termometr Konig
- termometr CaterChef
- termometr Save Demp
- termometr Comark
- termometr Fora
- termometr AGM
- termometr Beaba
- termometr Grado
- termometr La Crosse
- termometr Hartig And Helling
- termometr Pacom
- termometr Bearware
- termometr Bioland
- termometr Global Tronics
- termometr Blue Circle Medical
- termometr Okoia
- termometr Silvergear
- termometr Uebe
- termometr Dittmann
- termometr Sensitec
- termometr TFA Dostmann
- termometr CDN
- termometr Emga
- termometr Hartmann
- termometr Premiumful
- termometr MostEssential
- termometr VDH
- termometr Telesystem
- termometr Pancontrol
- termometr General
- termometr Ebro
- termometr Arya
- termometr RK Technology
- termometr Mobi
- termometr TQC
- termometr Bintoi
- termometr Jumper
- termometr Elem6
- termometr Thermoval
- termometr FlinQ
- termometr Pasha
- termometr Innovo
- termometr Delta Ohm
- termometr Guide
- termometr InfiRay
- termometr Neno
- termometr PCE Instruments
- termometr Knikker
- termometr AvaTemp
- termometr EasyLife
- termometr Alter
- termometr Unknown
- termometr Yummly
- termometr Eks
- termometr Gima
- termometr Aspen
- termometr Salva Tec
- termometr Radiant
- termometr Kuchenprofi
- termometr WBTT
- termometr Welby
- termometr Prologue
- termometr A&D
- termometr ClimeMET
- termometr Senseca
- termometr A&D Medical
- termometr Alphamed
- termometr Mediblink
- termometr Cofoe
- termometr Cresta Care
- termometr Nurcraft Care
Najnowsze instrukcje dla termometr

8 Kwietnia 2025

7 Kwietnia 2025

6 Kwietnia 2025

3 Kwietnia 2025

3 Kwietnia 2025

3 Kwietnia 2025

2 Kwietnia 2025

2 Kwietnia 2025

2 Kwietnia 2025

1 Kwietnia 2025