Instrukcja obsługi La Crosse Technology TX55U-IT


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla La Crosse Technology TX55U-IT (4 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/4
Model: TX55U-IT
DC: 030817
Wind Speed
Features
• Wind speed
• Replaceable wind cups
Wind sensor is powered by the batteries in the
Thermo-hygro sensor (not included).
Wind sensor has a cord the inserts into
Thermo-hygro sensor.
Power
• This is a corded sensor that is powered from the Thermo-hygro sensor (TX31U-IT or TX22U-IT)
Replace Wind Cups
1. In the bottom center of the wind cups is a plastic lock pin. Gently pry the lock pin out
of the wind cups.
2. Firmly grasp the wind cups and pull straight off the transmitter.
3. Check that the metal magnet is in the wind cups.
4. Check to be sure there is a metal bearing in the wind cups or on the stem of the
transmitter where the cups attach.
5. Look at your new wind cups and be sure there is a bearing and magnet in place.
6. Install the cups onto the wind transmitter and press rmly.
7. Insert a new lock pin into the cups and push rmly until the lock pin is ush with the
bottom of the cups.
Wind Sensor
Lock Pin
Wind Cups
Bearing Magnet
Mast Holder
The Wind sensor should be within 30 feet of the Thermo-hygro sensor to allow a
secure cord connection. The batteries in the Thermo-hygro sensor power the Wind
sensor.
Mount in an open area clear for 50 feet in all directions.
Place the Wind sensor as high as you can install it. In most cases 6 ft above the peak
of the roof (or more) is required for accurate readings. (Avoid tall trees or other
obstructions that may block or reect the wind).
Cups should be below the wind mast.
Cord: Carefully thread the Wind Cord through the mast holder and be sure the cord ts
in the slot or hole at the end, designed to prevent the cord from being pinched.
Do not wrap sensor cord around mast. Secure cord in as straight a line as possible
down the mast and over to the thermo-hygro sensor.
Straight mast holder: Be sure the mast holder is positioned correctly before locking
into the Wind sensor. This is a secure lock that takes time and patience to undue.
Elbow mast holder: Double-check that the Wind sensor, elbow mast holder and
straight mast holder are positioned correctly before locking into each other and the Wind
sensor. This is a secure lock that takes time and patience to undue.
Note: Be sure not to over tighten U bolts around the mast, then attached to the mast
holder, as that can crack the mast holder.
Mounting Masts:
Best to use a non-conductive material (e.g. treated wood, electrical grade metal or
electrical grade pvc). The issue is the static electricity transmission capability of the
entire pipe, which can lead to erratic wind readings, or loss of signal.
Masts should not be more than 1 1/4 inches in diameter to avoid blocking wind.
Mounting
Vertical
mast
Wind - cups
Horizontal panel


Specyfikacje produktu

Marka: La Crosse Technology
Kategoria: Niesklasyfikowane
Model: TX55U-IT

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z La Crosse Technology TX55U-IT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane La Crosse Technology

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024