Installation and Operating Instructions
Master copy of the Instructions
Heat Pump
HPMI2 - 8
HPMI2 - 12
HPMI2 - 16
HPMO2 - 8 HPMO2 - 12 HPMO2 - 16/23
2
This device may be used by children aged 8 years and over and
by persons with reduced physical, sensory or mental abilities
or lack of experience and knowledge, if they are supervised
or have been instructed concerning the safe use of the device
and have understood the resulting hazards. Children must not
play with the device. Cleaning and maintenance of the device
may not be carried out by children without supervision.
The HPM2.Z heat pump is a hermetically
sealed unit and it contains uorinated
greenhouse gases.
WARNING
Do not use any agents to speed up the defrosting or cleaning
process other than those recommended by the Manufacturer.
Store the device in a room without any constantly operating
sources of ignition (for example: an open ame, an operating
gas device or an operating electric heater). Do not puncture
or burn the device. Note that refrigerants may be odourless.
The device is to be installed, operated and stored in a room with
adequate space and cubic area (see the table).
NOTE: The Manufacturer may provide relevant examples or additional information on refrigerant’s odour.
This equipment is intended for use by qualied or trained users
in shops, light industry and on farms, or for use at home by
those who have no specialist knowledge.
3
EN-115B_f.1420
1. Familiarisation with the contents of this manual will enable the device to be installed and operated correctly, ensuring its
long-lasting and reliable operation.
2. The device must be installed in compliance with national installation regulations.
3. An electrical installation that is operational and carried out in accordance with PN-IEC 60364.
4. Considering its intended use, the device may only be installed and operated in closed heating systems in accordance with
EN 12828, taking into account the relevant installation, service and operating instructions.
Work on the refrigeration circuit must only be carried out by authorised specialists.
Initial commissioning is to be carried out by an Authorised Installer or a designated authorised person.
5. Unsuitable ambient conditions may cause damage to the installation and jeopardise operational safety (avoid air pollution
by halogenated alkanes contained e.g. in paints, solvents and cleaning agents, avoid constant high air humidity e.g. due to
frequent drying of laundry).
6. The installation of the device and the electrical and plumbing work must be carried out by a specialised service company
and the instructions for the assembly and use of the product must be strictly observed.
7. All installation work must be carried out with the electricity and water supply being cut off.
8. Sparks may occur due to an electrostatic discharge, which can ignite the leaking refrigerant (R32). Touch earthed objects,
e.g. heating or water pipes, to dissipate static charges before carrying out work.
9. Hot surfaces may cause burns.
10. Direct contact with the liquid and gaseous refrigerant may cause serious damage to health.
11. The electrical installation must be tted with residual current protective devices and means to ensure that the equipment
is disconnected from the power source, where the distance between the contacts of all the poles is not less than 3mm.
12. The heat pump is a surge-sensitive device and the electrical installation must therefore include surge protection devices.
13. There is a hazard of scalding in the event of an open ame.
14. R32 is the refrigerant used; this is an air displacing, colourless, odourless gas that forms a ammable mixture with air.
Conditions for safe and reliable operation
Description of the device
The HPM2.Z heat pump is an device designed for heating/cooling a building and heating tap water.
The unit consists of two modules:
- The outdoor HPMO2 module: a compressor heat pump.
The working principle of the unit is to capture heat from the environment and to transfer it to the heating circuit in the
building. The low-temperature heat of the air is transferred through an evaporator to the heat pump system lled with
a refrigerant, which turns into a gas as it evaporates. From the evaporator, the gas is drawn in by the compressor, which
raises its temperature during its compression and directs it to the condenser. In the condenser, heat is transferred to the
refrigerant, which lls the central heating system, and the cooled liquid ows through the expansion valve and returns to the
evaporator, after which the whole process starts again. In the case of cooling, this cycle is reversed and the heat is extracted
from the building and discharged outside.
- The indoor HPMI2 module: a hydraulic module equipped with a controller for the entire system.
The working principle of the unit is based on the demand-dependent capacity control of the heat pump compressor with an
activation of the electrical auxiliary heater via the controller of the indoor module. The indoor module controller regulates
the heating output according to a pre-set heating curve. If the heat pump is not able to cover the building’s heating demand
on its own, the controller automatically activates the electrical auxiliary heater which, together with the heat pump produces
the desired heating medium temperature.


Specyfikacje produktu

Marka: Kospel
Kategoria: pompa ciepła
Model: HPM2.Z-12

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Kospel HPM2.Z-12, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje pompa ciepła Kospel

Kospel

Kospel HPM2.Z-8 Instrukcja

29 Września 2024
Kospel

Kospel HPM2.C-12 Instrukcja

29 Września 2024
Kospel

Kospel HPM2.C-8 Instrukcja

29 Września 2024
Kospel

Kospel HPM2.Z-12 Instrukcja

29 Września 2024
Kospel

Kospel HPM2.Z-16 Instrukcja

29 Września 2024
Kospel

Kospel HPM2.C-16 Instrukcja

29 Września 2024

Instrukcje pompa ciepła

Najnowsze instrukcje dla pompa ciepła

Balay

Balay 3SB288BE Instrukcja

9 Października 2024
Arçelik

Arçelik AHPH-MM08 Instrukcja

9 Października 2024
Arçelik

Arçelik AHPH-MM12 Instrukcja

9 Października 2024
Arçelik

Arçelik AHPH-MM16 Instrukcja

9 Października 2024
Balay

Balay 3SB3091BR Instrukcja

8 Października 2024
Remeha

Remeha Elga Ace 4 kW Instrukcja

7 Października 2024
Miele

Miele TWV780WPS Instrukcja

4 Października 2024
Samsung

Samsung AE260RNWMEG Instrukcja

4 Października 2024
AEG

AEG T858M6OBC Instrukcja

4 Października 2024
AEG

AEG T859M6OBC Instrukcja

4 Października 2024