A. Main Function:
1. Radio-controlled function in DCF format
2. Weather forcast for 4 states: sunny, semi-sunny, cloudy, rainy
3. Indoor trend indication of temperature/humidity
4. indication of the comfort index
5. Temperature detect range: -20°C ~ 50°C
6. Humidity detect range : 10% RH ~ 95% RH
7. Alarm, snooze (delay 5 minutes alarm)
8. Day of the week in 7 languages
9. LED backlight
10. DST-Daylight saving time
11. Moon phase
12. Word time zone set, -12/+12 hours
B. Power on & Reset
1. While Power-On or reset, the LCD is completely lit for 3 seconds, and after the beep, RCC
receiving mode is activated.
C. Instruction of operating the keys
1. Key functions: Eight functional keys: CLOCK; ALARM; UP; DOWN; 12/24; MAX/MIN;
SNZ/LIGHT; C/F.
Function
Operation
CLOCK ALARM UP DOWN SNZ/LIGHT 12/24 C/F MAX/MIN
Standard mode
Click -------- Alarm on/off -------- -------- Backlight on 12/24
switchable
°C /°F
switch
Display
MAX/MIN
Temperature
and humidity
Hold Enter time
setting
Enter Alarm
Setting
-------- Enter RCC state
forcefully
-------- -------- -------- Clear Max/min
Temperature
and humidity
Time set
Click Confi rm The
setting
-------- One step
forward
One step
backward
Backlight on -------- -------- --------
Hold -------- -------- 8steps/second
forward
8steps/second
backward
-------- -------- -------- --------
Alarm set
Click -------- Confi rm the
setting
One step
forward
One step
backward
Backlight on -------- -------- --------
Hold -------- -------- 8steps/second
forward
8steps/second
backward
-------- -------- -------- --------
2. Standard mode key operation:
a. Hold CLOCK 2 seconds, enter time setting.
b. Press ALARM, turn alarm on/off.
c. Hold ALARM 2 seconds, enter alarm setting.
d. Press 12/24 to switch 12/24HR under time set mode.
e. Press C/F to switch °C/°F.
f. Press SNZ/LIGHT to turn on backlight 5 seconds.
g. When the alarm activates, press SNZ/LIGHT key. Don‘t press any key, the Snooze function
will activate and repeat four times.
h. Press “down” key for 3 seconds to enter into RCC receiving mode.
i. Press “MAX/MIN” key to check maximal and minimum of temperature and humidity.
j. Hold “MAX/MIN” key 2 seconds to clear all record of temperature and humidity
3
k. Under the RCC receiving mode, press “DOWN” key 2 seconds to exit the RCC receiving
mode.
3. Time setting:
a. Hold CLOCK 2 seconds, enter time setting mode.
b. Setting sequence is: Year → Month → Date → Language → Hour → Minute → exit
c. Push CLOCK key to confi rm current setting and enter next setting
d. Click UP key, the setting will go ahead one step; Hold this key 2 seconds, the setting will run
forward by 8 steps/second.
e. Click DOWN key, the setting will backward for one step; Hold this key, the setting will run back
by 8 steps/second.
f. The system will exit automatically if no key is operated in 20 seconds.
4. Alarm setting:
a. Hold ALARM 2 seconds to enter alarm setting.
b. Setting sequence is : hour → minute → exit.
c. Click ALARM to confi rm setting and enter next setting state.
d. Click UP key, the setting will go ahead one step; Hold this key 2 seconds, the setting will run
forward by 8 steps/second.
e. Click DOWN key, the setting will backward for one step; Hold this key, the setting will run back
by 8 steps/second.
f. The system will save the setting and exit automatically if no key is operated in 20 seconds.
D. Function and effect
1. RCC receiving function:
a. How to enter RCC receiving status.
I. It will into RCC receiving state automatically when power on or resetting.
II. It enters RCC receiving automatically at 2:00, 3:00, 4:00, 5:00 everyday.
b. RCC receiving time is 7 minutes.
c. It will receive radio signal automatically at 1:00-3:00 am, if it doesn‘t receive radio signal it will
start receiving at 4:00 and 5:00, if the signal has been received then the next RCC receiving
time is 1:00 am next day.
d. If can’t receive radio signal during 1:00 to 5:00, then next RCC receiving time is 1:00 next
day.
e. If the alarm rings during RCC receiving, system will exit RCC receiving and enter alarm
function.
f. When the DST signal is received, the DST symbol on the LCD will light, and the setting is
changed into daylight saving time.
g. If you change the time setting when the RCC symbol is lit, all the RCC symbols on the display
will be switched off.
2. Alarm function:
a. the BUZZER will ring for 2 seconds as below:
0 – 10 sec.: one “beep” per second
10 – 20 sec.: two “beeps” per second
20 – 30 sec.: four “beeps” per second
after 30 sec.: “beeps” continuously
b. When ringing, click SNZ/LIGHT key once to enter states 5 minutes snooze states, exit if any
other key is pushed.
3. System will stop temperature detection when RCC receiving or alarm ringing.
4. The indoor temperature display range: 0°C -- +50°C (32F -- +122F)
5. The indoor temperature proposed operating range: 0°C -- +40°C (32F -- +104F)
6. The indoor humidity range: 20% --- 95%
Specyfikacje produktu
Marka: | Konig |
Kategoria: | Stacje pogodowe |
Model: | KN-WS200 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Konig KN-WS200, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Stacje pogodowe Konig
8 Sierpnia 2024
8 Sierpnia 2024
8 Sierpnia 2024
Instrukcje Stacje pogodowe
- Stacje pogodowe Livoo
- Stacje pogodowe Hyundai
- Stacje pogodowe Viking
- Stacje pogodowe TFA
- Stacje pogodowe Auriol
- Stacje pogodowe Techno Line
- Stacje pogodowe Emos
- Stacje pogodowe Hama
- Stacje pogodowe Denver
- Stacje pogodowe Trevi
- Stacje pogodowe Alecto
- Stacje pogodowe ADE
- Stacje pogodowe Cotech
- Stacje pogodowe Oregon
- Stacje pogodowe Cresta
- Stacje pogodowe AcuRite
- Stacje pogodowe Ventus
- Stacje pogodowe Technoline
- Stacje pogodowe Irox
- Stacje pogodowe UPM
- Stacje pogodowe Kemot
- Stacje pogodowe La Crosse
- Stacje pogodowe Meade
- Stacje pogodowe Prologue
Najnowsze instrukcje dla Stacje pogodowe
15 Stycznia 2025
12 Stycznia 2025
15 Października 2024
15 Października 2024
14 Października 2024
13 Października 2024
13 Października 2024
13 Października 2024
13 Października 2024
12 Października 2024