Instrukcja obsługi Konig 2 x 200W
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Konig 2 x 200W (30 stron) w kategorii Błysk. Ta instrukcja była pomocna dla 8 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/30
KN-STUDIO70
MANUAL (p. 2)
Studio Flash
ANLEITUNG (S. 4)
Studioblitz
MODE D’EMPLOI (p. 6)
Flash d’atelier photographique GEBRUIKSAANWIJZING (p. 8)
Studioflitser
MANUALE (p. 10)
Studio Flash
MANUAL DE USO (p. 12)
Flash de Estudio
HASZNÁLATI ÚTMUTATÓ (o. 14.)
Stúdióvaku
KÄYTTÖOHJE (s. 16)
Salama studiokäyttöön
BRUKSANVISNING (s. 18)
Studioblixt NÁVOD K POUŽITÍ (s. 20)
Studiový blesk
MANUAL DE UTILIZARE (p. 22)
Bliţ de studio ΕΓΧΕΙΡΙΔΙΟ XPHΣ ΣH (σελ. 24)
Στούντιο Flash
BRUGERVEJLEDNING (s. 26)
Studie blitz
VEILEDNING (s. 28)
Studioblitz
2
ENGLISH
Studio Flash
Preparing Your Flash for Use
1. Carefully remove the flash unit from the box. The unit is supplied with a modeling lamp, power cord, flash
tube (installed) and synch cord.
2. Mount the flash unit on an appropriate light stand and adjust the angle to suit.
3. Install the modeling light by carefully screwing it into the receptacle. CAUTION: Do not touch the lamp with
your bare hands. Oil residue from your fingers can cause the surface of the lamp to heat unevenly and
explode.
4. Before plugging the power cord into the wall socket, be certain that the power switch is set to the off “O”
position.
5. Turn the power switch to the on “—” position. Check the settings on the following page.
Photo Cell
Ready Light
Power Output Knob
3.5 Synch cord input
Fuse Cover
Umbrella Socket
Tilt adjustment
Remote On/Off
Test Button
Modeling Lamp/ Beeper
Power On/Off
Power Cord
Mounting Knob
Setting the Flash Unit’s Controls
Photo Cell: This Photo Cell allows the flash to fire.
Ready Light: This light will glow red while the unit is charging. When the unit is ready to fire, the light will glow
green.
Power Output Knob: This controls the power ratio, adjustable from full power, down to 1/8 power. If the
modeling lamp is turned on, the modeling lamp will also adjust in brightness. NOTE: When adjusting the
power from full power to a lower setting, press the test button to release the power in the capacitor.
3.5mm Synch Cord Input: A synch cord is provided with your flash unit. The input is a 3.5mm mini plug.
Fuse Cover: Protective Fuse.
Umbrella Socket: Place the umbrella shaft in this socket.
Tilt Adjustment: Allows you to tilt the flash unit.
Remote On/Off: Push this button to turn the built-in photo cell on or off. When on, the photo cell will trigger
the flash when any other flash fires.
Test: To fire the flash without taking a picture, push the flash button.
Modeling Light/Beeper
Middle Position: “—” Modeling Light & Beeper ON
Up Position: “O” Modeling Light & Beeper OFF
Down Position: “=” Modeling Light On & Beeper OFF
Mounting Knob: Mount the light onto a light stand.
We recommend testing the mono light in advance to determine the results that produce the effect which you
find most appealing.
Technical Data
Maximum Output Power 200 Watt/Seconds
Maximum Guide Number 165 (ISO 100/ft)
100% Recycling Time 3-5 seconds
3
Power Adjustment 1/8th to Full Power
Adjustable
Modeling Lamp On/Off Switch
Tracking
Colour Temperature Daylight 5500 Kelvin
+/-100 Kelvin
Triggering Methods Synch Cord
Test Button
Internal Photo Cell
Triggering Voltage 5 V DC
Synch Distance Up to 36 ft
Voltage Range 220-240 V AC 50/60 Hz
Flash Tube User Replaceable
Weight 1.5 lbs
Caution
• Even unplugged, the unit maintains considerable internal voltage. There are no user serviceable parts
inside. Do not disassemble! Refer to an authorized service centre for any repairs.
• Do not exceed 75 Watts modeling lamp. The excess heat can damage the unit.
• Do not use a snoot with these units. The heat can damage the flash housing.
• Do not touch the bulb when it is hot!
• When not in use, disconnect from the power supply.
• Avoid sudden impacts as this can damage the flash tube and/or modeling lamp!
Safety precautions:
To reduce risk of electric shock, this product should ONLY be
opened by an authorized technician when service is required.
Disconnect the product from mains and other equipment if a
problem should occur. Do not expose the product to water or
moisture.
Maintenance:
Clean only with a dry cloth. Do not use cleaning solvents or abrasives.
Warranty:
No guarantee or liability can be accepted for any changes and modifications of the product or damage caused
due to incorrect use of this product.
General:
Designs and specifications are subject to change without notice.
All logos brands and product names are trademarks or registered trademarks of their respective holders and
are hereby recognized as such.
Keep this manual and packaging for future reference.
Attention:
This product is marked with this symbol. It means that used electrical and electronic products should
not be mixed with general household waste. There is a separate collections system for these products.
Specyfikacje produktu
Marka: | Konig |
Kategoria: | Błysk |
Model: | 2 x 200W |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Konig 2 x 200W, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Błysk Konig
15 Sierpnia 2024
Instrukcje Błysk
- Błysk Sony
- Błysk Canon
- Błysk Sigma
- Błysk Nikon
- Błysk Godox
- Błysk Minox
- Błysk LogiLink
- Błysk Ricoh
- Błysk Rollei
- Błysk Lastolite
- Błysk Olympus
- Błysk Pulsar
- Błysk COLBOR
- Błysk GVM
- Błysk Pentax
- Błysk Quantum
- Błysk Ikan
- Błysk Impact
- Błysk Aputure
- Błysk Dörr
- Błysk Metz
- Błysk Nissin
- Błysk Profoto
- Błysk Hähnel
- Błysk Vello
- Błysk Goodram
- Błysk Yongnuo
- Błysk Xit
- Błysk Genaray
- Błysk Sunpak
- Błysk SeaLife
- Błysk Neewer
- Błysk Xantech
- Błysk Kenko
- Błysk Elinchrom
- Błysk Cullmann
- Błysk Rotolight
- Błysk Cactus
- Błysk PolarPro
- Błysk ANDYCINE
- Błysk Westcott
- Błysk Ikelite
- Błysk Kaiser Fototechnik
- Błysk Triopo
Najnowsze instrukcje dla Błysk
9 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024