ENGLISH
INSTRUCTION MANUAL
Rechargeable
Pro Thermal Imager
49,152 (256 × 192)
PIXELS TO
TROUBLESHOOT
HOT AND COLD
SPOTS
ADJUSTABLE
EMISSIVITY
FROM 0.01
TO 0.99
TRANSFER PHOTOS
WIRELESSLY
USING INTEGRATED
WI-FI HOTSPOT
RECHARGEABLE
LITHIUM ION
BATTERY
T
I
I
I
II
290
-4° – 752°F
-20° –
400°C
2m
EP 5016393
5001748
SCAN TO
DOWNLOAD
THE APP
2
GENERAL SPECIFICATIONS
The Klein Tools TI290 is a high resolution, USB rechargeable professional
Thermal Imager; power on to view unseen hot and cold spots for instant
troubleshooting. The meter provides high and low temperature points, crosshairs
to pinpoint specific temperatures, and options for temperature alarms. Wi-Fi
setting allows the meter to transfer and share images for reporting.
Environment: Indoor: DO NOT expose to moisture rain or snow.
Operating Altitude: 6562 ft. (2000 m)
Relative Humidity: <85% non-condensing
Operating Temp: ° ° ° °32 to 113 F (0 to 45 C)
Storage Temp: -4° to 140°F (-20° to 60°C )
Sensor: VOx Microbolometer
Sensor Resolution: 49152 pixels (256 × 192)
Field of View (FOV): 55.6 +/- 2.8 degrees
Frame Rate: <9 Hz
Sensitivity: ≤50 mK
Temperature Range: ° °-4 to 752°F (-20 to 400°C)
Temperature Resolution: 0.1°F/0.1°C
Temperature Accuracy: ±2°C 3.F) or 2%, whichever is greater
NOTE: Not calibrated below -10°C (1F)
Temperature Display: High, Low, and Center point
Temperature Settings: °F / °C
Emissivity: 0.01 to 0.99 adjustable (0.95 default)
Display Type: 3.5" (89 mm) TFT LCD
Color Palettes: Ironbow, Rainbow, Grayscale
Image Format: JPG
Image Storage: Up to 10000 thermal images
Image Transfer: USB, or Wi-Fi using the Klein Tools App
Dimensions: 4.48" × 3.10" × 1.06" (113.7 × 78.7 × 26.9 mm)
Weight: 7.5 oz. (213 g)
Power: Lithium polymer battery (USB rechargeable)
3.7V / 2000mAh (7.4 Wh)
Required Charger Voltage / Current : 5V DC, 2A
Charging Current / Time: 1A / 3 hours
Auto Power Off: User-selectable for 5, 10, or 30 minutes
Pollution degree: 2
Drop Protection: 6.6' (2 m)
Standards: Conforms to UL STD. 61010-1
Certi ed to CSA STD. C22.2 No. 61010-1
Specifications subject to change.
ENGLISH
5001748
3
WARNINGS
Read, understand, and follow these instructions to ensure safe
operation. Failure to observe these warnings can result in risk of
re or electric shock. Keep these instructions for future reference.
• DO NOT use the product if it is damaged or modified. Damaged or
modified batteries may exhibit unpredictable behavior resulting in fire,
explosion, or injury.
Risk of fire and burns. DO NOT open, crush, heat above specified
maximum temperature or incinerate. Prolonged exposure to
direct sunlight can result in elevated temperatures
.
If the battery’s internal temperature gets too high, the unit will shut
down until the internal temperature is lowered.
• DO NOT expose to moisture, rain, or snow.
• DO NOT subject to impacts or drops greater than 6.6 ft. (2 m). Drops
larger than this may not show signs of damage, but internal components
may have been compromised. It is advisable to replace the unit if any
such severe events occur.
There are no user-serviceable parts inside. DO NOT open or attempt to repair.
WARNING SYMBOLS ON TESTER
Warning or caution
Risk of Electrical Shock
Read instructions before using
OTHER SYMBOLS ON TESTER
Conformi Européenne: Conforms with European
Economic Area directives
UKCA: UK Conformity Assessment
This product has been independently tested by Intertek
and meets applicable published standards.
WEEE: Electronics disposal
USB rechargeable
USB-C Port Cover (bottom of unit)
CAUTION
BURN HAZARD. Reflective materials may have a higher actual
temperature than the measured temperature. Set emissivity to
match the object being measured (see Emissivity section).
• Do not point the camera at the sun or any other strong energy source.
This can affect the accuracy of the camera or cause damage to the sensor.


Specyfikacje produktu

Marka: Klein Tools
Kategoria: Sprzęt pomiarowy
Model: TI290

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Klein Tools TI290, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Sprzęt pomiarowy Klein Tools

Klein Tools

Klein Tools VDV501-770 Instrukcja

9 Października 2024
Klein Tools

Klein Tools ET18 Instrukcja

9 Października 2024
Klein Tools

Klein Tools VDV211-048 Instrukcja

9 Października 2024
Klein Tools

Klein Tools ET500 Instrukcja

6 Października 2024
Klein Tools

Klein Tools NCVT-2 Instrukcja

6 Października 2024
Klein Tools

Klein Tools 45001 Instrukcja

5 Października 2024
Klein Tools

Klein Tools HVNCVT-1 Instrukcja

5 Października 2024
Klein Tools

Klein Tools TI220 Instrukcja

4 Października 2024
Klein Tools

Klein Tools TI222 Instrukcja

4 Października 2024
Klein Tools

Klein Tools TI290 Instrukcja

4 Października 2024

Instrukcje Sprzęt pomiarowy

Najnowsze instrukcje dla Sprzęt pomiarowy

Stamos

Stamos S-LS-28 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-86 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-61 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-81 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-84 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-74 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-76 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-42 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-75 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-35 Instrukcja

15 Października 2024