INSTRUCTION MANUAL
ENGLISH
FRANÇAIS pg. 29
ESPAÑOL pg. 15
400A AC Auto
Digital Clamp
NON-CONTACT
VOLTAGE TESTIN
AUTO-RANGING
DATA HOLD
RANGE HOLD
TEMPERATURE
AUDIBLE CONTI
600V
400A
20M
Ω
5001748
CL220
-4
1832°F
-4
1000°C
2m
True RM
Measuremen
Technology
CAT III
600V
2
GENERAL SPECIFICATIONS
Klein Tools CL220 is an automatically ranging, true root-mean-
square (TRMS) digital clamp-meter that measures AC current via the
clamp, AC/DC voltage, resistance and continuity via test-leads, and
temperature via a thermocouple probe.
Operating Altitude: 6562 ft. (2000m)
Relative Humidity: <95% non-condensing
Operating Temp: ° ° ° °32 to 122 F (0 to 50 C)
Storage Temp: ° ° ° °14 to 122 F (-10 to 50 C)
Accuracy: Values stated at 65° to 83°F (18° to 28°C)
Temp Coefcient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
Dimensions: 8.46" x 3.54" x 1.50" (215 x 90 x 38 mm)
Weight: 11.04 oz. (313 g) including batteries
Calibration: Accurate for one year
Auto Power-Off (APO): After approx. 10 minutes of inactivity
Standards: IEC EN 61010-1, 61010-2-032, 61010-2-033.
IEC EN 61326-1, 61326-2-2.
Conforms to UL STD.61010-1,
61010-2-032,61010-2-033;
Certified to CSA STD.C22.2 NO. 61010-1,
61010-2-032,61010-2-033.
Pollution degree: 2
Accuracy: ± (% of reading + # of least significant digits)
Drop Protection: 6.6 ft. (2m)
Safety Rating: CATIII 600V, Class 2, Double insulation
Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
AC Voltage
(V AC)
200.0mV 0.1mV ±(2.5% + 10 digits)
2.000V 1mV
±(2.0% + 5 digits)
20.00V 10mV
200.0V 100mV
600V 1V
DC Voltage
(V DC)
200.0mV 0.1mV ±(1.0% + 8 digits)
2.000V 1mV
±(1.0% + 3 digits)
20.00V 10mV
200.0V 100mV
600V 1V
Input Impedance: 10MΩ
Frequency Range: 45 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
AC Current
(A AC)
2.000A 1mA ±(2.5% + 30 digits)
20.00A 10mA
±(2.0% + 10 digits)200.0A 100mA
400A 1A
Frequency Range: 50 to 60Hz
Resistance
200. 0.1Ω ±(1.2% + 5 digits)
2.000KΩ 1Ω
±(1.2% + 3 digits)
20.00kΩ 10Ω
200.0kΩ 10
2.000MΩ 1kΩ
20.00MΩ 10kΩ ±(2.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
Temperature
°F
-4to 10°F
1
°F
±(1.2% + 7 digits)
11° to 1832°F
±(1.2% + 6 digits)
Temperature
°C
-4to -12°C
1
°C ±(1.2% + 4 digits)
-1to -1000°C
±(1.2% + 3 digits)
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
Audible signal <10Ω, max current 1.5mAContinuity Check:
3 samples per secondSampling Frequency:
"OL" indicated on displayOverload:
"-" on display indicates negative polarityPolarity:
3 ½ digit, 2000 Count LCDDisplay:

Specyfikacje produktu

Marka: Klein Tools
Kategoria: Meetapparatuur
Model: CL220

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Klein Tools CL220, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Meetapparatuur Klein Tools

Klein Tools

Klein Tools CL220 Instrukcja

28 Września 2024
Klein Tools

Klein Tools CL800 Instrukcja

28 Września 2024
Klein Tools

Klein Tools CL700 Instrukcja

28 Września 2024
Klein Tools

Klein Tools CL150 Instrukcja

28 Września 2024
Klein Tools

Klein Tools ET140 Instrukcja

19 Września 2024

Instrukcje Meetapparatuur

Najnowsze instrukcje dla Meetapparatuur

Bosch

Bosch PTD 1 Instrukcja

28 Września 2024
Monacor

Monacor CT-3 Instrukcja

28 Września 2024
Qubino

Qubino ZMNHXD2 Instrukcja

28 Września 2024
Qubino

Qubino ZMNHXD8 Instrukcja

28 Września 2024
Qubino

Qubino ZMNHXD3 Instrukcja

28 Września 2024
Qubino

Qubino ZMNHXD4 Instrukcja

28 Września 2024
Qubino

Qubino ZMNHXD5 Instrukcja

28 Września 2024
BENNING

BENNING EV 3-2 Instrukcja

26 Września 2024
BENNING

BENNING CM 12 Instrukcja

26 Września 2024