Instrukcja obsługi Klein Tools 501-915

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Klein Tools 501-915 (36 stron) w kategorii Sprzęt pomiarowy. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/36
INSTRUCTION MANUAL
Cable Length Meter
ENGLISH
501-915
MEASURES AND
DISPLAYS CABLE
LENGTH IN FEET OR
METERS
USES TDR METHOD
TO MEASURE CABLE
LENGTH VIA ITS VOP
CONSTANT
MEASURES MOST
TYPES OF COPPER
CABLE INCLUDING
DATA, VOICE, VIDEO,
LAMP WIRE, SIAMESE,
AND NM CABLES
CAPABLE OF
MEASURING LENGTH
TO OPEN AND SHORT
FAULTS
EXTRA-LARGE FULL
COLOR BACK-LIT LCD
SCREEN
BUILT-IN TONE
GENERATOR WITH
SELECTABLE TONE
CADENCE TO EASILY
TRACE CABLES WITH AN
ANALOG TONE PROBE
(NOT INCLUDED)
CONSERVES POWER
ADJUSTABLE AUTO
POWER OFF (APO)
07:30 55%05/29/2020
Library
Type Home
CAT4UT VOP
68.3%
0.0 ft
0.0 ft
0.0 ft
0.0 ft
Pair 1-2
Pair 3-6
Pair 4-5
Pair 7-8
FRANÇAIS p. 25
ESPAÑOL pg. 13
2 m
2
GENERAL SPECIFICATIONS
The Klein Tools Cable Length Meter is a portable time domain
reflectometer (TDR) cable length meter. It measures cable length,
calibrates Velocity of Propagation (VoP) values, finds faults in cables,
and provides tone generation for cable tracing.
Environment: Indoors
Operating Altitude: 10000 ft. (3050 m)
Relative Humidity: <90% non-condensing
Operating Temperature: 32° to 122°F (0° to 50°C)
Storage Temperature: -4° to 140°F (-20° to 60°C)
Input Protection: 30V peak 50/60Hz AC or DC
Common Cable Length Ranges: Coax: 0 to 2000' (0 to 610 m)
Data: Electrical: 0 to 1500' (0 to 457 m) 0 to 1000' (0 to 305 m)
Measurement Method: Time Domain Reflectometry
Measurement Units: Feet, meters
VoP Range: 0 to 99.9%
Accuracy: ± (2% + 3 ft. or 1 m) with known VoP and consistent
cable parameters
Tone Generation: Constant: Alternating: 1200Hz, 1000/1500 Hz
Batteries: 2× AA alkaline
Battery Low Level: Approx. 2.2V
Standby:Battery Life: Active: Approx. 15 hours Approx. 3 years
Auto Power Off (APO)
:
Test Mode: 5 to 20 minutes (default = 10 min.)
Tone Mode: 60 minutes, not adjustable.
Dimensions: 6.2" × 2.6" × 1.2" (15.7 × 6.6 × 3.0 cm)
Weight: 12.0 oz. (340 grams) with batteries
Specifications subject to change.
WARNINGS
To ensure safe operation and service of the meter, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
The Cable Length Meter should NOT be used on energized cabling systems.
Internal components of the Cable Length Meter are protected up to 30V
peak AC or DC. Connecting the meter to voltages above this range may
pose a safety hazard to the user and the meter.
ENGLISH
SYMBOLS ON METER
Warning: Potential for personal injury.
Caution: Potential for damage or destruction to equipment.
Always wear approved
eye protection Do NOT use on
energized circuits Read
Instructions
Do not place equipment and its accessories in the trash. Items must
be properly disposed of in accordance with local regulations.
UKCA - United
Kingdom
Conformity
Assessment
Conformité Européenne.
Conforms with European
Economic Area directives.
Battery
type and
orientation
3
DEFINITIONS
Velocity of
Propogation
(VoP)
Velocity of Propagation (VOP) is the speed of
an electrical signal traveling through a cable,
measured as a percentage of the speed of light
BNC-Connector A BNC Connector is a common connector for a
coax cable, often associated with security systems
Time Domain
Re ectometry
(TDR)
TDR technology, is a technology that uses VoP
values to accurately measure cable lengths
FEATURE DETAILS
Front of Meter Back of MeterTop of Meter
6
9
4
5
10
711
8
12
1. LCD Screen
2. RJ45 Port
3. BNC Port
4. Battery Cover
5. Power Button
6."One Dot" Button:
Select, Library,
Right Arrow
7.
"Two Dot" Button:
More, Edit, Cancel,
No, On/Off
8.
"Three Dot" Button - Type, Return, Home, Left Arrow, Yes
9. Test Button
10. Save Button
11. Arrow Up Button
12. Arrow Down Button
13. Male Coax-BNC to Alligator Clips
14. Male Coax-BNC to Female Coax-F
15. Male Coax-BNC to Male Coax-F
16. CAT-6 RJ45 to CAT-6 RJ45
17. Female Coax-BNC to Male Coax-BNC
18. Female Coax-BNC to Male Coax-F
23
NOTE: No user-
serviceable parts
inside meter.
16
17 18
15
14
13
CABLE LENGTH METER
www.kleintools .com
HS
1

Specyfikacje produktu

Marka: Klein Tools
Kategoria: Sprzęt pomiarowy
Model: 501-915

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Klein Tools 501-915, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Sprzęt pomiarowy Klein Tools

Klein Tools

Klein Tools VDV501-770 Instrukcja

9 Października 2024
Klein Tools

Klein Tools ET18 Instrukcja

9 Października 2024
Klein Tools

Klein Tools VDV211-048 Instrukcja

9 Października 2024
Klein Tools

Klein Tools ET500 Instrukcja

6 Października 2024
Klein Tools

Klein Tools NCVT-2 Instrukcja

6 Października 2024
Klein Tools

Klein Tools 45001 Instrukcja

5 Października 2024
Klein Tools

Klein Tools HVNCVT-1 Instrukcja

5 Października 2024
Klein Tools

Klein Tools TI220 Instrukcja

4 Października 2024
Klein Tools

Klein Tools TI222 Instrukcja

4 Października 2024
Klein Tools

Klein Tools TI290 Instrukcja

4 Października 2024

Instrukcje Sprzęt pomiarowy

Najnowsze instrukcje dla Sprzęt pomiarowy

Stamos

Stamos S-LS-28 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-86 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-61 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-81 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-84 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-74 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-76 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-42 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-75 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-35 Instrukcja

15 Października 2024