AC Wire-in Single and/or Multiple Station (up to 24 Devices)
Photoelectric Smoke Alarm with 9 Volt Battery Back Up and
“HUSH” Control to temporarily silence nuisance alarms.
Thank you for purchasing this smoke alarm. It is an important
part of your family’s home safety plan. You can trust this product
to provide the highest quality safety protection. We know you
expect nothing less when the lives of your family are at stake.
Kidde alarms and accessories CAN ONLY BE interconnected with
other Kidde alarms and accessories as well as specified brands and
models of interconnect compatible alarms. Connection of Kidde
products to a non-specified manufacturer’s interconnect system,
or connection with non-specified equipment from another manu-
facturer into an existing Kidde system could result in nuisance
alarming, failure to alarm, or damage to one or all of the devices
in the interconnect system. Refer to the User’s Guide supplied with
each Kidde product for interconnect compatible models, brands,
and devices. Refer to the wiring instructions in section 3 for NFPA
initiating device limits.
Smoke Alarm User’s Guide
21008164-EN Rev A
1375-7213-00
P12040
For model: P12040
SIGNALING
LISTED
UL
WARNING! BATTERY DOOR WILL NOT CLOSE UNLESS A
BATTERY IS PRESENT. REMOVAL OF THE SMOKE ALARM
BATTERY AND DISCONNECTING OR LOSS OF AC POWER
WILL RENDER THE SMOKE ALARM INOPERATIVE.
ELECTRICAL RATING: 120 VAC, 60HZ, 80mA maximum per alarm
(maximum 80mA for originating unit with 24 devices interconnected).
CONTENTS OF THIS MANUAL
1 -- RECOMMENDED LOCATIONS FOR SMOKE ALARMS
2 -- LOCATIONS TO AVOID
3 -- INSTALLATION INSTRUCTIONS
4 -- OPERATION AND TESTING
5 -- NUISANCE ALARMS
6 -- MAINTENANCE
7 -- LIMITATIONS OF SMOKE ALARMS
8 -- GOOD SAFETY HABITS
9 -- NFPA PROTECTION STANDARD 72
10 --
CALIFORNIA STATE FIRE MARSHAL REQUIRED INFORMATION
11 -- SERVICE AND WARRANTY
1. RECOMMENDED LOCATIONS FOR ALARMS
Locate the first alarm in the immediate area of the bedrooms.
Try to monitor the exit path as the bedrooms are usually farthest
from the exit. If more than one sleeping area exists, locate addi-
tional alarms in each sleeping area.
Locate additional alarms to monitor any stairway as stairways act
like chimneys for smoke and heat.
Locate at least one alarm on every floor level.
Locate an alarm in every bedroom.
Locate an alarm in every room where electrical appliances are
operated (i.e. portable heaters or humidifiers).
Locate an alarm in every room where someone sleeps with the
door closed. The closed door may prevent an alarm not located
in that room from waking the sleeper.
Smoke, heat, and combustion products rise to the ceiling and
spread horizontally. Mounting the smoke alarm on the ceiling in
the center of the room places it closest to all points in the room.
Ceiling mounting is preferred in ordinary residential construction.
For mobile home installation, select locations carefully to avoid
thermal barriers that may form at the ceiling. For more details,
see MOBILE HOME INSTALLATION below.
When mounting an alarm on the ceiling, locate it at a minimum
of 4” (10cm) from the side wall (see figure 1).
When mounting the alarm on the wall, use an inside wall with
the top edge of the alarm at a minimum of 4” (10cm) and a
maximum of 12” (30.5cm) below the ceiling (see figure 1).
Put smoke alarms at both ends of a bedroom hallway or large
room if the hallway or room is more than 30 ft (9.1 m) long.
Install Smoke Alarms on sloped, peaked or cathedral ceilings
at or within 3 ft (0.9m) of the highest point (measured hori-
zontally). NFPA 72 states: “Smoke alarms in rooms with ceiling
slopes greater than 1 ft in 8 ft (.3m in 2.4m) horizontally shall
be located on the high side of the room.” NFPA 72 states: “A
row of alarms shall be spaced and located within 3 ft (0.9m) of
the peak of the ceiling measured horizontally” (see figure 3).
MOBILE HOME INSTALLATION
Modern mobile homes have been designed and built to be energy
efficient. Install smoke alarms as recommended above (refer to
RECOMMENDED LOCATIONS and figures 1 and 2).
FIGURE 2 FIGURE 3
FIGURE 1