Instrukcja obsługi JUNG NRSLC0834USV

JUNG UPS NRSLC0834USV

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla JUNG NRSLC0834USV (24 stron) w kategorii UPS. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/24
1
Manual
Emergency system set
NRS .. 0834 ..
Emergency system set with UPS
NRS .. 0834 2 ..-
2
Short description
In accordance with DIN VDE 0834, the emergency system set is meant to be used in
bathrooms for people with disabilities. The DIN VDE 0834 must be considered during
install tiona and operation the emergency system. of
The set is comprised of:
Emergency signal NRS .. 0834 RM ..
-Pull cord push button NRS .. 0834 ZT ..
Reset button NRS .. 0834 AT ..
Power supply NRS .. 0834 NT ..
Only included in the emergency system set with UPS (NRS .. 0834- 2 ..):
UPS module NRS .. 0834 USV ..
Available separately:
Service unit NRS .. 0834 DZE ..
Call button . 0834 RT .. NRS .
Service terminal NRS DZT 20 WW
-Surface mounted housing for service terminal NRS DZT AP WW
Deflexion pulley set NRS ULR 0834
Spare parts:
Accumulator for UPS module NRS AKKU 130
-Pull cord ZS 34 KO5S
Functional description
When an emergency call is triggered with the pull cord, the red light on the push-button
confirms the successful call. The emergency call is indicated visually and acoustically by
the emergency signal. In stand-by mode, a light makes it easier to find the pull cord push-
button.
For other use cases, the visual and acoustic call can be transformed into a continuous
signal, for example, using a jumper. It is also possible to disable the acoustic call.
The unmonitored call can be sent from the emergency signal via a floating contact.
Pressing the reset button stops the emergency call.
If there is no superordinate emergency power supply, the UPS module must be used. The
UPS module ensures that the emergency call is triggered even in the event of power
failure. The accumulator included is easy to replace and available as a spare part. This
emergency power supply is monitored, every disruption is reported.
In battery mode, a short acoustic signal is sent to the emergency signal every 12 seconds.
Two short acoustic signals every 12 seconds are sent to the emergency signal to indicate
an accumulator disturbance.
3
The optional service unit serves to monitor call forwarding. The service unit would not only
indicate the emergency call acoustically but also visually. The call can be muted for
20 seconds or the additional call in the office disabled in absence.
The optional call button also includes lights to be found more easily and to confirm a
successful emergency call.
The service terminal shows unmonitored calls of several emergency calls centrally. It
reports the emergency calls acoustically and visually as plain text. Just as for the service
unit, call forwarding can de disabled on the service terminal in absence or interrupted for
20 seconds. Surface-mounted housing is optionally available.
In accordance with the Dutch standard NEN 1814, the length of the pull cord of the push-
button can be extended to 20 m using the deflexion pulley set. In Germany, this extension
is not obligatory but could be deemed necessary in certain cases. When the pull cord is
installed using the deflexion pulley set, even a person lying in the floor can send an
emergency call pulling at any point of the cord.
The emergency call system is ready for operation as soon as power is supplied. The UPS
module is only able to fully switch to emergency power supply if it was connected to supply
voltage for several hours. It could be up to 6 hours, depending on how long the
accumulator has been charged.


Specyfikacje produktu

Marka: JUNG
Kategoria: UPS
Model: NRSLC0834USV

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z JUNG NRSLC0834USV, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą