1. Function
The Time Switch display is a system component and is installed in a box
as per DIN 49073 (deep box recommended) in conjunction with the Time
Switch insert. The unit facilitates the programmed, time-controlled
switching of various lamps (refer to Specifications) up to a maximum of
1000 W.
Product features:
Simple operation through a four-key field.
Two independent program memories for a total of up to 18 switching
time events (e. g. nine ON and nine OFF time events).
Factory-programmed switching times in two program memories A B.,
Timer function C ( automatic shut-off after a preset time).
Random function.
Astro function.
Summer/winter time change-over by key operation.
Individual astro function by astro time shift.
Actuation via extensions (insert) possible.
Reset to facilitate to select factory default setting.
Power reserve: Programs permanently saved. Current data (time,
month, date, day) stored up to 24 hours (maintenance-free and
without backup batteries).
Stand: Aug-07 325 048 03
Licht Management Universal timer switch display
Ref.-no.: ..5201 DTU..
2. Programming
Note: If no operation is made for longer than 2 minutes during
programming, the Time Switch will automaticliy return to displaying the
current data. Programming can be cancelled any time by pressing the key
SET for about 3 seconds.
2.1. Setting Current Data
Prior to entering your data please make a reset to bring back the device to
factory default setting:
Depress the MODE and SET keys at the same time until all display
segments light up for a short time (approx. 7 sec.). This completes the
reset.
To put the Time Switch into operation, please enter the current data:
Hold the SET key depressed until the display reads prog.
2
Licht Management Universal timer switch display
Ref.-no.: ..5201 DTU..
Use key ON or OFF to select the following settings (please refer to the
diagramm):
Time, Date : Set current data
A : Programming memory A
B : Programming memory B
Astro :Shift astro times
Accept the Time, Date symbol by shortly depressing the SET key. The
Time Switch is now in the current data setting mode.
c
c
c
cc Setting summer/ winter time
The currently selected function is blinking. Use key ON or OFF to set
summer time S or winter time W.
Accept by shortly depressing the SET key.
d
d
d
dd Setting the current month
The month display is blinking. Use key ON or OFF to set the month
(01..12).
Accept by shortly depressing the SET key.
e
e
e
ee Setting the current date
The day display is blinking. Use key ON or OFF to set the day (01..31) .
Accept by shortly depressing the SET key.
f
f
f
ff Setting the current day
The weekday display is blinking. Use key ON or OFF to set the day
(MO..SU).
Accept by shortly depressing the SET key.
g
g
g
gg Setting the current hour
The hour display is blinking. Use key ON or OFF to set the hours (00..23).
Accept by shortly depressing the SET key.
h
h
h
hh Setting the current minute
The minute display is blinking.Use key ON or OFF to set the minutes
(00..59).
Accept by shortly depressing the SET key.
The Time Switch has taken over the current data and changed over to its
normal operating mode.
2.2. Factory Setting and Reset
Manual operation has, in all cases, priority over automatic mode. In the two
program memories A B and , independent programs can be stored (e.g.
for everyday life, holidays, etc.). A maximum of 18 different switching time
3


Specyfikacje produktu

Marka: JUNG
Kategoria: przełącznik
Model: ES5201DTU

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z JUNG ES5201DTU, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje przełącznik JUNG

JUNG

JUNG SL1180 Instrukcja

27 Września 2024
JUNG

JUNG ES5201DTU Instrukcja

27 Września 2024
JUNG

JUNG SL1180-1 Instrukcja

27 Września 2024
JUNG

JUNG AS5544.03VWW Instrukcja

27 Września 2024
JUNG

JUNG CD5024WW Instrukcja

27 Września 2024
JUNG

JUNG BTA17102 Instrukcja

27 Września 2024
JUNG

JUNG A1180-1 Instrukcja

24 Września 2024
JUNG

JUNG A1180 Instrukcja

24 Września 2024
JUNG

JUNG ASLS1280-1 Instrukcja

20 Września 2024
JUNG

JUNG BTLC17101P Instrukcja

13 Września 2024

Instrukcje przełącznik

Najnowsze instrukcje dla przełącznik

Netgear

Netgear GS110TPP Instrukcja

15 Października 2024
ZyXEL

ZyXEL SFP-LHX1310-40-D Instrukcja

14 Października 2024
Tripp Lite

Tripp Lite B005-DPUA4 Instrukcja

11 Października 2024
Lancom

Lancom CS-8132F Instrukcja

9 Października 2024
Lancom

Lancom YS-7154CF Instrukcja

9 Października 2024
TP-Link

TP-Link Festa FS328G Instrukcja

9 Października 2024
Totolink

Totolink SW24DM Instrukcja

9 Października 2024
Totolink

Totolink SW1008P Instrukcja

9 Października 2024
Totolink

Totolink SW24G2 Instrukcja

9 Października 2024
Cudy

Cudy FS1006P Instrukcja

9 Października 2024