Pressure
Switch
Thermistor
Pilot
Pilot
Generator
Fusible
Link
Hi-Limit
135° F Hi-Limit
(150° F)
Gas Valve
Temperature Control
Orange
Red
SENSENPOTPOT
TH/PP
+
(PP)
Valve
(TH)
Red
Red
White
Black
TP/TH
TH
TP 1
2
Black
Black
3a 3b
4a
5a
Black to TH
Yel
low
to T
P
White to TP/TH
Red to TP
Laars
5b
Piezo Ignitor
Black
Pilot Coil
4b
Try to light the pilot.
Does pilot light?
Does pilot stay on
when gas valve
knob is released?
500+ mV @ PP
and PP-TH
terminals? (1)
1. Verify gas is on.
2. Check for air in gas line.
3. Is pilot tube clogged?
If voltage is found at one and not
the other, replace Fuse Link. Check
for Roll out, Soot, Downdrafting,
Low Gas Pressure, etc.
No
1. Check P/G output (1) .
2. Check for shorted wires.
3. Check pilot coil.
1. Check for low Pilot Generator
output.
2. Check for partial shorts
or loose wires.
3. Replace Pilot Generator.
500+ mV @
and both terminals
of Fuse Link? (2)
500+ mV @ Red
Wire of Pressure
Switch going to
rocker switch? (4b)
Perform Back Pressure Test. If
2.5 PSI or more, replace switch.
If less, check pump, filter, etc.
for pressure problem.
500+ mV @ Red wire
of from Hi-Limits to
Pressure Switch (4a)
1. Check each High Limit
individually. (3a&b)
2. Check if damage to
bypass or heat exchanger.
Set gas valve knob to pilot position.
Set rocker switch to OFF.
Set rocker switch to ON
Is there 200+ mV
@ Red wire of
Pressure Switch? (4b)
Yes
Is there 200+ mV
@ TH terminal of
the Gas Valve?
No
Is there 500+ mV
@ TH/PP on
Temp. Board?
Yes
Move rocker switch
to OFF. Rotate Gas
Valve Knob to ON.
Move rocker switch
to ON. Does heater fire?
Is there 500+ mV
@ Valve (TH) on
Temp. Board?
No
Yes
Yes
Is there 500+ mV
@ TH terminal of
Gas Valve?
Yes
Replace
Gas Valve
No
Yes
Yes
Yes
Yes
Yes
No
No
Check and/or replace
black wire from
Valve (TH) terminal
of Temp. Board and
TH terminal of Gas Valve.
No
Perform Thermistor Test, see below.
Replace Temp. Board
Check rocker
switch
Yes
No
Yes
No
No
No
No
No
Disconnect Pot wires and jump pot
terminals. If voltage drops to 200+ mV,
replace Temp. Control (P/N
R0058200).
Mat #0754, Rev. C 09/05
HOT SHOT (100K) HEATER TROUBLESHOOTING

Black from
Pressure Switch
Black to
Gas Valve (TH)
Yellow to
Gas Valve (PP)
Thermistor
10 K Ohms
Orange
SENSENPOTPOT
TH/PP
+
(PP)
Valve
(TH)
Black
Laars
Temperature Control
T-Stat Board
Ω at 20 K
COMmA Ω
v
10A
10.00
V---
∼
V
Ω
Waterpik Technologies
Laars & Jandy Products
2M
200K
20K
2K
200
200m
2m
2
20
200
1000 2 0 0
750
ONOFF
PNP
NPN
A---
77º F.
Temperature Control Test
Temp Resistance Temp Resistance
50° F 19.898 K Ohms 78° F 9.735 K Ohms
51° F 19.435 K Ohms 79° F 9.483 K Ohms
52° F 18.871 K Ohms 80° F 9.284 K Ohms
53° F 18.382 K Ohms 81° F 9.079 K Ohms
54° F 17.902 K Ohms 82° F 8.864 K Ohms
55° F 17.473 K Ohms 83° F 8.655 K Ohms
56° F 16.988 K Ohms 84° F 8.450 K Ohms
57° F 16.549 K Ohms 85° F 8.253 K Ohms
58° F 16.150 K Ohms 86° F 8.057 K Ohms
59° F 15.710 K Ohms 87° F 7.871 K Ohms
60° F 15.314 K Ohms 88° F 7.687 K Ohms
61° F 14.923 K Ohms 89° F 7.509 K Ohms
62° F 14.547 K Ohms 90° F 7.335 K Ohms
63° F 14.193 K Ohms 91° F 7.166 K Ohms
64° F 13.823 K Ohms 92° F 7.001 K Ohms
65° F 13.477 K Ohms 93° F 6.840 K Ohms
66° F 13.138 K Ohms 94° F 6.685 K Ohms
67° F 12.813 K Ohms 95° F 6.531 K Ohms
68° F 12.492 K Ohms 96° F 6.384 K Ohms
69° F 12.186 K Ohms 97° F 6.238 K Ohms
70° F 11.893 K Ohms 98° F 6.099 K Ohms
71° F 11.593 K Ohms 99° F 5.963 K Ohms
72° F 11.309 K Ohms 100° F 5.829 K Ohms
73° F 11.032 K Ohms 101° F 5.700 K Ohms
74° F 10.765 K Ohms 102° F 5.572 K Ohms
75° F 10.502 K Ohms 103° F 5.449 K Ohms
76° F 10.250 K Ohms 104° F 5.327 K Ohms
77° F 10.000 K Ohms
Thermistor Temp/Resistance Chart
Thermistor Test
Disconnect the thermistor from the T-Stat Board before performing test.
Place a good thermometer in the pool skimmer and turn on the filter pump.
Set your meter to Resistance (20 K Ohms or above). Measure the resistance
between the two leads of the thermistor. Compare this reading to the chart.
Set Gas Valve Knob to pilot position
Set heater rocker switch to On
Set thermostat to maximum
Is there 200+ mV
@ Red wire of
Pressure Switch? (4b)
Yes
Is there 200+ mV
@ TH terminal of
the Gas Valve?
No
Is there 500+ mV
@ TH/PP on
Temp. Board?
Yes
Move rocker switch
to OFF. Rotate Gas
Valve Knob to ON.
Move rocker switch
to ON.Does heater fire?
Is there 500+ mV
@ Valve (TH) on
Temp. Board?
No
Yes
Yes
Is there 500+ mV
@ TH terminal of
Gas Valve?
Yes
Replace
Gas Valve
No
No
No
Check and/or replace
black wire from
Valve (TH) terminal
of Temp. Board and
TH terminal of Gas Valve.
Perform Thermistor Test, see below.
Replace Temp. Board
Check rocker
switch
No Disconnect Pot wires and jump pot
terminals. If voltage drops to 200+ mV,
replace Temp. Control (P/N
R0058200).
HOT SHOT (100K) HEATER TROUBLESHOOTING
Mat #0754, Rev. C 09/05
Specyfikacje produktu
Marka: | JANDY |
Kategoria: | grzejnik |
Model: | Hot Shot |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z JANDY Hot Shot, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje grzejnik JANDY

28 Maja 2024

19 Maja 2024

11 Maja 2024
Instrukcje grzejnik
- grzejnik Bauknecht
- grzejnik Tesy
- grzejnik Electrolux
- grzejnik DeLonghi
- grzejnik Götze & Jensen
- grzejnik Gorenje
- grzejnik SHX
- grzejnik Tefal
- grzejnik Bosch
- grzejnik Candy
- grzejnik Global
- grzejnik Brentwood
- grzejnik Nobo
- grzejnik Bestway
- grzejnik Nedis
- grzejnik Black & Decker
- grzejnik Adler
- grzejnik Rinnai
- grzejnik Domo
- grzejnik Ardes
- grzejnik Taurus
- grzejnik Orbegozo
- grzejnik Blaupunkt
- grzejnik DeWalt
- grzejnik Einhell
- grzejnik HP
- grzejnik Bimar
- grzejnik Mesko
- grzejnik Honeywell
- grzejnik Concept
- grzejnik Chauvet
- grzejnik ECG
- grzejnik Unold
- grzejnik Fuxtec
- grzejnik Broan
- grzejnik Mestic
- grzejnik Wilfa
- grzejnik Eureka
- grzejnik DEDRA
- grzejnik Emerio
- grzejnik Crane
- grzejnik Melissa
- grzejnik Enders
- grzejnik Beper
- grzejnik MPM
- grzejnik Emos
- grzejnik Ravanson
- grzejnik Thermex
- grzejnik Perel
- grzejnik Fagor
- grzejnik Trotec
- grzejnik Everdure
- grzejnik Thomson
- grzejnik Trumatic
- grzejnik Izzy
- grzejnik Velleman
- grzejnik Klarstein
- grzejnik Danfoss
- grzejnik Güde
- grzejnik Cecotec
- grzejnik Steba
- grzejnik NewAir
- grzejnik Qlima
- grzejnik Scarlett
- grzejnik Eden
- grzejnik GUTFELS
- grzejnik TriStar
- grzejnik Dimplex
- grzejnik Aurora
- grzejnik Harvia
- grzejnik Omega Altise
- grzejnik Clatronic
- grzejnik SVAN
- grzejnik Innoliving
- grzejnik Argoclima
- grzejnik Solac
- grzejnik Elro
- grzejnik Hama
- grzejnik Heller
- grzejnik Orion
- grzejnik Blumfeldt
- grzejnik Vemer
- grzejnik Sencor
- grzejnik Zibro
- grzejnik Becken
- grzejnik Thermotec
- grzejnik Reer
- grzejnik Alpatec
- grzejnik AccuLux
- grzejnik Sygonix
- grzejnik AstralPool
- grzejnik Cotech
- grzejnik Tectro
- grzejnik Vitek
- grzejnik Eurom
- grzejnik Maestro
- grzejnik Mill
- grzejnik Smith&Brown
- grzejnik Sogo
- grzejnik Sonnenkönig
- grzejnik Proline
- grzejnik Lifesmart
- grzejnik Lasko
- grzejnik Flama
- grzejnik Yellow Garden Line
- grzejnik Toyotomi
- grzejnik AENO
- grzejnik Soler & Palau
- grzejnik Monzana
- grzejnik Bestron
- grzejnik Optimum
- grzejnik Rotel
- grzejnik Profile
- grzejnik TaoTronics
- grzejnik Anslut
- grzejnik Logik
- grzejnik Eldom
- grzejnik Maxxmee
- grzejnik Creda
- grzejnik Kambrook
- grzejnik Noveen
- grzejnik Waldbeck
- grzejnik Waves
- grzejnik Ecoteck
- grzejnik Mirpol
- grzejnik Orava
- grzejnik Ausclimate
- grzejnik Hortus
- grzejnik Mission Air
- grzejnik Bromic
- grzejnik Airo
- grzejnik Ionmax
Najnowsze instrukcje dla grzejnik

25 Października 2024

25 Października 2024

21 Października 2024

21 Października 2024

26 Września 2024

25 Września 2024

25 Września 2024

25 Września 2024

25 Września 2024

24 Września 2024