Document # 11-0053 11-0053 LC-1_Manual_1.9.doc
LC-1 Digital Air/Fuel Ratio (Lambda)
Sensor Controller Manual
Warning!
The Oxygen Sensor used in this device gets very hot in operation.
Do not touch the hot sensor. Do not let a hot sensor touch a
combustible surface. Do not use the sensor with or near flammable
liquids or gases. Failure to heed these warnings may result in severe
burns, explosions or fires.
When installed in the exhaust, the oxygen sensor MUST be
connected and operating with the LC-1 whenever the car is running.
An un-powered oxygen sensor will be quickly damaged when
exposed to hot exhaust gases.
- 2 -
1 Overview................................................................................................................................... 3
2 Mounting and Wiring the LC-1 ................................................................................................. 4
2.1 Indicator LED and Calibration button hookup: .................................................................. 5
2.2 Connecting the LC-1 to an ECU or data logger ................................................................ 6
2.3 Electrical Grounding Concerns..................................................................................... 6
2.4 Mounting the sensor using a Bung. .................................................................................. 6
2.5 How to fabricate a copper heat sink ................................................................................. 8
3 First Time Use......................................................................................................................... 8
4 Calibration ................................................................................................................................ 9
4.1 Free air calibration.......................................................................................................... 9
4.2 Sensor heater calibration............................................................................................... 9
4.3 Calibration Schedule .................................................................................................... 10
5 Remote display and recording of Lambda and/or AFR.......................................................... 10
5.1 Analog Lambda/AFR instrument..................................................................................... 10
5.2 Digital XD-16 Instrument................................................................................................. 11
5.3 Laptop recording of AFR or Lambda .............................................................................. 11
5.4 Multi channel AFR recording with multiple LC-1’s and/or LM-1...................................... 11
6 Programming the LC-1........................................................................................................... 12
6.1 Installing the LM Programmer Software ......................................................................... 12
6.2 Hooking up the LC-1 device to the computer ................................................................. 12
6.3 Resetting the calibration data ......................................................................................... 13
6.4 Updating the Firmware.................................................................................................... 13
6.5 Programming the analog outputs.................................................................................... 14
6.5.1 Advanced output programming................................................................................ 14
7 Tips, Tricks and Troubleshooting ........................................................................................... 16
7.1 General measurement requirements .............................................................................. 16
7.2 Vehicles with ‘smog-pumps’............................................................................................ 16
7.3 Measuring at the tail-pipe................................................................................................ 16
7.4 Single Cylinder Engines.................................................................................................. 16
7.5 Diesel Engines ................................................................................................................ 16
7.6 Reference cell or Pump cell circuit open or shorted errors............................................. 16
7.7 Sensor Timing Errors ...................................................................................................... 17
7.8 Analog Output tricks/hints ............................................................................................... 17
8 Advanced Topics.................................................................................................................... 17
8.1 Connecting the LC-1 to simulate a narrow band oxygen sensor.................................... 17
Appendix A: LC-1 Cable Pinouts.................................................................................................. 19
Appendix B: LED blinking codes .................................................................................................. 20
Appendix C: LC-1 Error Codes and Troubleshooting Tips........................................................... 21
Appendix D: Limited Warranty...................................................................................................... 22
Appendix E: Kit Contents.............................................................................................................. 23
Revision History............................................................................................................................. 24
- 3 -
1 Overview
The LC-1 is a stand-alone Wideband Controller used to measure the Air/Fuel Ratio (AFR) or
Lambda for an engine. For gasoline-driven engines, the theoretically optimal air fuel ratio is 14.7
pounds of air for every pound of fuel. At this ratio, theoretically, all available oxygen in the air
combines with all available fuel. This ratio is called the stoichiometric ratio. Stoichiometric for
different fuels are as follows:
Gasoline 14.7
LPG (Propane) 15.5
Methanol 6.4
Ethanol 9.0
CNG 17.2
Diesel 14.6
The measurement Lambda is the actual air fuel ratio over the stoichiometric ratio. A Lambda
measurement of “1” equates to the air fuel ratio of 14.7 (for gasoline engines). When Lambda is
less than 1 the engine runs “rich”, i.e., unburned fuel exists in the exhaust stream. If lambda is
greater than 1 the engine runs lean, i.e., free oxygen (02) is present in the exhaust. Depending on
the engine, maximum power is typically delivered when the engine runs slightly rich (for example
at lambda values of 0.8 to 0.9 for most engines). This instrument provides a means to measure
the actual air fuel ratio or lambda in the engine in operation directly from the exhaust. For this a
special wide-band oxygen sensor is used to measure the lambda value derived from the oxygen
content (or lack thereof) of the exhaust gases.


Specyfikacje produktu

Marka: Innovate
Kategoria: Różnorodny
Model: LC-1

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Innovate LC-1, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Różnorodny Innovate

Instrukcje Różnorodny

Najnowsze instrukcje dla Różnorodny

Walkera

Walkera Goggle 3 Instrukcja

15 Października 2024
Walkera

Walkera Goggle 4 Instrukcja

15 Października 2024
Somfy

Somfy Telis Lounge Instrukcja

5 Października 2024
Navman

Navman NavBus Instrukcja

5 Października 2024
Trelock

Trelock LS 320 Instrukcja

5 Października 2024
DJI

DJI Phantom 3 Standard Instrukcja

5 Października 2024
Bobike

Bobike Maxi City Instrukcja

5 Października 2024
Tanita

Tanita 1210N Instrukcja

5 Października 2024
Kerbl

Kerbl 81685 Cat flap Instrukcja

5 Października 2024