Operating instructions
Ex protection related part
Vibration sensor category 1G / 1D
VSP01A
80007502/00 06/2018
UK
2
Remarks for safe use in hazardous areas
Functions and features
Use in hazardous areas according to the classification
II 1D
(group II, category 1D, apparatus for dust atmosphere).
Complies with the requirements of IEC 60079-0:2011 and IEC 60079-11:2011.
Use in hazardous areas according to the classification
II 1G
(group II, category 1G, apparatus for gas atmosphere).
Complies with the requirements of the standards IEC 60079-0:2011 and
IEC 60079-11:2011.
EC type examination certificate
Baseefa12ATEX0248X
IEC Ex type examination certificate
IECEx BAS 12.0133 X
Marking (see unit or technical data sheet)
1GD
Ex ia IIC T6 Ga
Ex ia IIIC T80 ºC IP 65 Da
(-55 ºC < Ta < +60 ºC)
Certified Temperature Range
Ex ia IIC T6 Ga (-55 °C < Ta < +60 °C) (gas)
Ex ia IIIC T80 °C IP 65 Da (-55 ºC < Ta < +60 ºC) (dust)
Ex ia IIC T4 Ga (-55 °C < Ta < +90 °C) (gas)
Ex ia IIIC T110 °C IP 65 Da (-55 °C < Ta < +90 °C) (dust)
Installation / Set-up
The units must only be installed, connected and set up by qualified staff. The qualified staff
must have knowledge of types of protection, regulations and provisions for apparatus in
hazardous areas.
Check whether the classification ( "Functions and features" and marking on the unit) is
suitable for the application.
Connection only to intrinsically safe circuits which are approved with the type examination
certificate and do not exceed the following maximum values:
Ui = 28 V, Ii = 93 mA, Pi = 0.65 W
3
UK
Installation remarks / Installation
Adhere to the respective national regulations and provisions as well as the relevant
installation regulations.
Do not mount the unit in the dust flow.
Avoid dust deposits on the units.
Protect the units and the cables efficiently against damage.
Fix the cable directly behind the sensor mounting position.
For the connections and the electrical characteristics please see the unit marking or the
technical data sheet.
Mounting drawing
Non-hazardous area Hazardous area
2
134
+
-
1: Non-hazardous area apparatus
(diagnostic unit)
2: Isolator / Barrier Box
3: Junction box
4: VSP01A
Special conditions for safe operation
The unit must be connected to the external diagnostic unit via a certified isolated barrier.
Special conditions of safe use for group II (dust):
The free end of the cable on the integral cable version of the apparatus must be terminated
in an appropriately dust-proof enclosure.
Maintenance / Repair
The unit must not be modified nor can it be repaired. In case of a fault please contact the
manufacturer.
If required, the technical data sheets, type examination certificates and EC declarations of
conformity can be obtained from the manufacturer. Indicate the article number.


Specyfikacje produktu

Marka: IFM
Kategoria: Niesklasyfikowane
Model: VSP01A

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z IFM VSP01A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane IFM

IFM

IFM TW2001 Instrukcja

14 Stycznia 2025
IFM

IFM EVC231 Instrukcja

13 Stycznia 2025
IFM

IFM UGT582 Instrukcja

13 Stycznia 2025
IFM

IFM TY0058 Instrukcja

13 Stycznia 2025
IFM

IFM OT5012 Instrukcja

11 Stycznia 2025
IFM

IFM SUH201 Instrukcja

11 Stycznia 2025
IFM

IFM LW2760 Instrukcja

5 Stycznia 2025
IFM

IFM AL2305 Instrukcja

5 Stycznia 2025
IFM

IFM E30560 Instrukcja

5 Stycznia 2025
IFM

IFM E30559 Instrukcja

5 Stycznia 2025

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane